title: "Anker Innovations Limited: MI80S Inverter (656W)"
url: https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80s-240v/
description: "CEC specs for Anker Innovations Limited: MI80S {240V}: 656W AC, 240V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Anker Innovations Limited: MI80S {240V} — CEC Inverter Specifications

Manufacturer: [**Anker Innovations Limited**](https://epri-peac.com/solar-equipment/brands/anker-innovations-limited/) Registry: **CEC Verified Engineering Specification**

Anker Innovations Limited: MI80S {240V} outputs 656 W AC at 240 V (2.7 A continuous, 15 A OCPD), ranking #743 of 2,343 CEC inverters at 97.23% efficiency with a 36-43 V MPPT window and 43 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 656 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 97.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Anker Innovations Limited: MI80S {240V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Anker Innovations Limited: MI80S {240V}.

For NEC 705.12 solar interconnection, Anker Innovations Limited: MI80S {240V} outputs 2.7 A continuous AC at 240 V and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Conversion efficiency scores 97.23% (#743 of 2,343, +0.41 pts vs overall CEC median).

## Where Does Anker Innovations Limited: MI80S {240V} Fall Across Listed CEC Models?

Output power comparison showing where Anker Innovations Limited: MI80S {240V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Dataset Percentiles Define Anker Innovations Limited: MI80S {240V}?

Relative ranking of Anker Innovations Limited: MI80S {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Anker Innovations Limited: MI80S {240V}?

Snapshot of Anker Innovations Limited: MI80S {240V} efficiency rank (#743), OCPD breaker size, MPPT span, and busbar verdict.

Eff #743 / 2,343

### 97.23% CEC Weighted Efficiency

+0.55 pts vs the 96.68% 240 V median; overall power rank #1,911 (656 W, below CEC median; higher than 18.4% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 2.7 A = 3.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 36 V - 43 V (Max 43 V DC)

Tracking span of 7.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 656.0W / 240 V -> 2.7 A | Breaker >= 1.25 * 2.7 = 3.4 A -> 15 A

CEC Inverters.csv for Anker Innovations Limited: MI80S {240V}: Paco=656.0 W, Vac=240 V, Vdcmax=43.0 V, Eff=97.23%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Anker Innovations Limited: MI80S {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Anker Innovations Limited: MI80S {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Anker Innovations Limited: MI80S {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 656 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 43 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 36 V - 43 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 17.3001 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.23% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Anker Innovations Limited: MI80S {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Anker Innovations Limited: MI80S {240V} at 240 V. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Anker Innovations Limited: MI80S {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Anker Innovations Limited: MI80S {240V}?

Minimum and maximum series solar module strings fitting Anker Innovations Limited: MI80S {240V} MPPT and 43 V limits.

Sampled CEC PV modules aligned within 36.0-43.0 V MPPT and 43.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-0-270tw/) | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |

## Which Competing Grid-Support Inverters Compare to Anker Innovations Limited: MI80S {240V}?

Peer 240 V CEC inverters near 656 W AC output such as Altenergy Power System Inc: DS3-S {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Altenergy Power System Inc: DS3-S {240V}**](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-ds3-s-240v/) Altenergy Power System Inc | 656 W | Tie (0 W) | 240.0 V | 43.0 V | 97.23% |
| [**Cherry Solution Co Ltd: CMI-600S-SA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-sa-240v/) Cherry Solution Co Ltd | 604 W | -52 W | 240.0 V | 50.0 V | 96.12% |
| [**Cherry Solution Co Ltd: CMI-600S-WA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-600s-wa-240v/) Cherry Solution Co Ltd | 604 W | -52 W | 240.0 V | 50.0 V | 96.12% |
| [**Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {240V}**](https://epri-peac.com/solar-equipment/inverters/chilicon-power-llc/chilicon-power-llc-cp-720-60-72-96-208-240-mc4-240v/) Chilicon Power LLC | 721 W | +65 W | 240.0 V | 70.0 V | 95.35% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Anker Innovations Limited: MI80S {240V}?

Check Anker Innovations Limited: MI80S {240V} (656 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 43 V DC on Anker Innovations Limited: MI80S {240V}.

### Anker Innovations Limited: MI80S {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.23%) and MPPT window (36-43 V) directly against Altenergy Power System Inc: DS3-S {240V} (656 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Anker Innovations Limited: MI80S {240V} by Anker Innovations Limited covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Anker Innovations Limited: MI80S {240V} require?

At 656 W continuous AC (240 V), continuous current is 2.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Anker Innovations Limited: MI80S {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Anker Innovations Limited: MI80S {240V} compare to Altenergy Power System Inc: DS3-S {240V}?

Anker Innovations Limited: MI80S {240V} delivers 656 W AC at 97.23% CEC efficiency with a 43 V DC ceiling, while Altenergy Power System Inc: DS3-S {240V} outputs 656 W at 240 V.

## Related Pages

Explore Anker Innovations Limited hardware, Altenergy Power System Inc: DS3-S {240V}, utility rates, and NEC 705.12 sizing calculators alongside Anker Innovations Limited: MI80S {240V}.

[All Anker Innovations Limited Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/anker-innovations-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Anker Innovations Limited

- [All Anker Innovations Limited Specs](https://epri-peac.com/solar-equipment/brands/anker-innovations-limited/)
- [Anker Innovations Limited: A17E1 {240V}](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-a17e1-240v/)
- [Anker Innovations Limited: X1-P6K-US {240V}](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-x1-p6k-us-240v/)
- [Anker Innovations Limited: MI80H {240V}](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80h-240v/)
- [Anker Innovations Limited: MI80 {240V}](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80-240v/)
- [Anker Innovations Limited: MI80L {240V}](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80l-240v/)