---
title: "Altenergy Power System Inc Inverter (1,821W)"
url: https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-qt2-480-480v/
description: "CEC specs for Altenergy Power System Inc: QT2-480 {480V}: 1,821W AC, 480V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Altenergy Power System Inc: QT2-480 {480V} — CEC Inverter Specifications

Manufacturer: [**Altenergy Power System Inc**](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) Registry: **CEC Verified Engineering Specification**

Altenergy Power System Inc: QT2-480 {480V} outputs 1,821 W AC at 480 V, 3-phase (2.2 A continuous, 15 A OCPD), ranking #1,948 of 2,343 CEC inverters at 96.02% efficiency with a 34-42 V MPPT window and 42 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 1,821 W

- **AC Voltage** : 480 V, 3-phase

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Altenergy Power System Inc: QT2-480 {480V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: QT2-480 {480V}.

For NEC 705.12 solar interconnection, Altenergy Power System Inc: QT2-480 {480V} outputs 2.2 A continuous AC at 480 V, 3-phase and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.02% (#1,948 of 2,343, -0.80 pts vs overall CEC median).

## Where Does Altenergy Power System Inc: QT2-480 {480V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: QT2-480 {480V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Altenergy Power System Inc: QT2-480 {480V}?

Relative ranking of Altenergy Power System Inc: QT2-480 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Altenergy Power System Inc: QT2-480 {480V}?

Snapshot of Altenergy Power System Inc: QT2-480 {480V} efficiency rank (#1,948), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,948 / 2,343

### 96.02% CEC Weighted Efficiency

-2.00 pts vs the 98.02% 480 V median; overall power rank #1,770 (1,821 W, below CEC median; higher than 24.4% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 2.2 A = 2.8 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 34 V - 42 V (Max 42 V DC)

Tracking span of 8.0 V; listed since 2023-05-11 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1821.0W / 480 V 3-phase -> 2.2 A | Breaker >= 1.25 * 2.2 = 2.8 A -> 15 A

CEC Inverters.csv for Altenergy Power System Inc: QT2-480 {480V}: Paco=1821.0 W, Vac=480 V, Vdcmax=42.0 V, Eff=96.02%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Altenergy Power System Inc: QT2-480 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: QT2-480 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: QT2-480 {480V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 1,821 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 42 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 34 V - 42 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 49.9063 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.02% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-05-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Altenergy Power System Inc: QT2-480 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: QT2-480 {480V} at 480 V, 3-phase.

Evaluates Altenergy Power System Inc: QT2-480 {480V} (15 A required OCPD at 480 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (480V)** | 40 A | 15 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (480V)** | 80 A | 15 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (480V)** | 120 A | 15 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (480V)** | 160 A | 15 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (480V)** | 240 A | 15 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Altenergy Power System Inc: QT2-480 {480V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: QT2-480 {480V} MPPT and 42 V limits.

Sampled CEC PV modules aligned within 34.0-42.0 V MPPT and 42.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: QT2-480 {480V}?

Peer 480 V, 3-phase CEC inverters near 1,821 W AC output such as Fronius International GmbH: Fronius Symo 100-3 480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Fronius International GmbH: Fronius Symo 100-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-100-3-480-480v/) Fronius International GmbH | 9,995 W | +8174 W | 480.0 V | 800.0 V | 97.42% |
| [**Fronius International GmbH: Fronius Symo 125-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-125-3-480-480v/) Fronius International GmbH | 12,500 W | +10679 W | 480.0 V | 800.0 V | 97.57% |
| [**Fronius International GmbH: Fronius Symo 150-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-150-3-480-480v/) Fronius International GmbH | 15,000 W | +13179 W | 480.0 V | 800.0 V | 97.47% |
| [**Fronius International GmbH: Fronius Symo Advanced 150-3 480 {480V}**](https://epri-peac.com/solar-equipment/inverters/fronius-international-gmbh/fronius-international-gmbh-fronius-symo-advanced-150-3-480-480v/) Fronius International GmbH | 15,197 W | +13376 W | 480.0 V | 800.0 V | 97.48% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: QT2-480 {480V}?

Check Altenergy Power System Inc: QT2-480 {480V} (1,821 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 42 V DC on Altenergy Power System Inc: QT2-480 {480V}.

### Altenergy Power System Inc: QT2-480 {480V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.02%) and MPPT window (34-42 V) directly against Fronius International GmbH: Fronius Symo 100-3 480 {480V} (9,995 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: QT2-480 {480V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

### What breaker and wire size does Altenergy Power System Inc: QT2-480 {480V} require?

At 1,821 W continuous AC (480 V, 3-phase), continuous current is 2.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Altenergy Power System Inc: QT2-480 {480V} require?

At 1,821 W AC and 480 V, 3-phase, continuous line current is 2.2 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

### How does Altenergy Power System Inc: QT2-480 {480V} compare to Fronius International GmbH: Fronius Symo 100-3 480 {480V}?

Altenergy Power System Inc: QT2-480 {480V} delivers 1,821 W AC at 96.02% CEC efficiency with a 42 V DC ceiling, while Fronius International GmbH: Fronius Symo 100-3 480 {480V} outputs 9,995 W at 480 V, 3-phase.

## Related Pages

Explore Altenergy Power System Inc hardware, Fronius International GmbH: Fronius Symo 100-3 480 {480V}, utility rates, and NEC 705.12 sizing calculators alongside Altenergy Power System Inc: QT2-480 {480V}.

[All Altenergy Power System Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Altenergy Power System Inc

- [All Altenergy Power System Inc Specs](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/)
- [Altenergy Power System Inc: ELS-114 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/)
- [Altenergy Power System Inc: ELS-114 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-208v/)
- [Altenergy Power System Inc: ELS-96 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-240v/)
- [Altenergy Power System Inc: ELS-96 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-208v/)
- [Altenergy Power System Inc: ELS-76 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-240v/)
