title: "Altenergy Power System Inc Inverter (altenergy-powe)"
url: https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-ez1-lv-120v/
description: "CEC specs for Altenergy Power System Inc: EZ1-LV {120V}: 915W AC, 120V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Altenergy Power System Inc: EZ1-LV {120V} — CEC Inverter Specifications

Manufacturer: [**Altenergy Power System Inc**](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) Registry: **CEC Verified Engineering Specification**

Altenergy Power System Inc: EZ1-LV {120V} outputs 915 W AC at 120 V (7.6 A continuous, 15 A OCPD), ranking #2,315 of 2,343 CEC inverters at 94.08% efficiency with a 28-45 V MPPT window and 45 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 915 W

- **AC Voltage** : 120 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 94.08%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Altenergy Power System Inc: EZ1-LV {120V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 120 V grid-support overview for Altenergy Power System Inc: EZ1-LV {120V}.

Ranking #1,854 of 2,343 CEC inverters (below CEC median; higher than 20.8% of peers), Altenergy Power System Inc: EZ1-LV {120V} is a grid-tied PV inverter delivering 915 W continuous AC at 120 V (7.6 A continuous). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Weighted CEC efficiency reaches 94.08% (-0.65 pts vs the 94.73% 120 V median) against peers like Northern Electric & Power Co Ltd: BDM-1200-LV {120V} (1,194 W).

## Where Does Altenergy Power System Inc: EZ1-LV {120V} Fall Across Listed CEC Models?

Marks Altenergy Power System Inc: EZ1-LV {120V} (915 W AC) across the California Energy Commission inverter AC capacity distribution.

## What Dataset Percentiles Define Altenergy Power System Inc: EZ1-LV {120V}?

Benchmarks Altenergy Power System Inc: EZ1-LV {120V} continuous AC output, 94.08% CEC weighted efficiency, and 15 A OCPD breaker demand.

## What Do the Dataset Ranks Show for Altenergy Power System Inc: EZ1-LV {120V}?

Four key NEC 705.12 and California Energy Commission metrics defining Altenergy Power System Inc: EZ1-LV {120V} by Altenergy Power System Inc.

Eff #2,315 / 2,343

### 94.08% CEC Weighted Efficiency

-0.65 pts vs the 94.73% 120 V median; overall power rank #1,854 (915 W, below CEC median; higher than 20.8% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 7.6 A = 9.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 28 V - 45 V (Max 45 V DC)

Tracking span of 17.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

### 120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 915.0W / 120 V -> 7.6 A | Breaker >= 1.25 * 7.6 = 9.5 A -> 15 A

CEC Inverters.csv for Altenergy Power System Inc: EZ1-LV {120V}: Paco=915.0 W, Vac=120 V, Vdcmax=45.0 V, Eff=94.08%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

## What Are the Published CEC Specifications for Altenergy Power System Inc: EZ1-LV {120V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Altenergy Power System Inc: EZ1-LV {120V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: EZ1-LV {120V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 915 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 120 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 45 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 28 V - 45 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 27.0161 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 94.08% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for Altenergy Power System Inc: EZ1-LV {120V}?

Evaluates Altenergy Power System Inc: EZ1-LV {120V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Altenergy Power System Inc: EZ1-LV {120V} (15 A required OCPD at 120 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| **150A Bus / 150A Main** | 30 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 200A Main** | 40 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| **200A Bus / 175A Main** | 65 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| **225A Bus / 200A Main** | 70 A | 15 A | 120V AC Coupled / Dedicated Transformer |

## Which CEC PV Module Strings Pair With Altenergy Power System Inc: EZ1-LV {120V}?

Sample PV string lengths aligned within 28-45 V MPPT and 45 V DC max at -10 C. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sampled CEC PV modules aligned within 28.0-45.0 V MPPT and 45.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-0-270tw/) | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |

## Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: EZ1-LV {120V}?

Competing CEC grid-support inverters near 915 W AC and 120 V, led by Northern Electric & Power Co Ltd: BDM-1200-LV {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Northern Electric & Power Co Ltd: BDM-1200-LV {120V}**](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-1200-lv-120v/) Northern Electric & Power Co Ltd | 1,194 W | +278 W | 120.0 V | 55.0 V | 96.23% |
| [**Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}**](https://epri-peac.com/solar-equipment/inverters/apparent-inc/apparent-inc-sg424-plus-120vac-60hz-ca-120v/) Apparent Inc | 326 W | -589 W | 120.0 V | 52.0 V | 90.97% |
| [**Apparent Inc: SG424U CA 120VAC 60Hz {120V}**](https://epri-peac.com/solar-equipment/inverters/apparent-inc/apparent-inc-sg424u-ca-120vac-60hz-120v/) Apparent Inc | 250 W | -665 W | 120.0 V | 48.9 V | 91.11% |
| [**Northern Electric & Power Co Ltd: BDM-1600-LV {120V}**](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-1600-lv-120v/) Northern Electric & Power Co Ltd | 1,597 W | +682 W | 120.0 V | 55.0 V | 96.31% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: EZ1-LV {120V}?

Check Altenergy Power System Inc: EZ1-LV {120V} (915 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 45 V DC on Altenergy Power System Inc: EZ1-LV {120V}.

### Altenergy Power System Inc: EZ1-LV {120V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (7.6 A continuous).

### Alternative Inverter Comparison

Compare efficiency (94.08%) and MPPT window (28-45 V) directly against Northern Electric & Power Co Ltd: BDM-1200-LV {120V} (1,194 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: EZ1-LV {120V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 120 V interconnection.

### What breaker and wire size does Altenergy Power System Inc: EZ1-LV {120V} require?

At 915 W continuous AC (120 V), continuous current is 7.6 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Altenergy Power System Inc: EZ1-LV {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 120 V means 120V AC Coupled / Dedicated Transformer.

### How does Altenergy Power System Inc: EZ1-LV {120V} compare to Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?

Altenergy Power System Inc: EZ1-LV {120V} delivers 915 W AC at 94.08% CEC efficiency with a 45 V DC ceiling, while Northern Electric & Power Co Ltd: BDM-1200-LV {120V} outputs 1,194 W at 120 V.

## Related Pages

Explore Altenergy Power System Inc hardware, Northern Electric & Power Co Ltd: BDM-1200-LV {120V}, utility rates, and NEC 705.12 sizing calculators alongside Altenergy Power System Inc: EZ1-LV {120V}.

[All Altenergy Power System Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Altenergy Power System Inc

- [All Altenergy Power System Inc Specs](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/)
- [Altenergy Power System Inc: ELS-114 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/)
- [Altenergy Power System Inc: ELS-114 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-208v/)
- [Altenergy Power System Inc: ELS-96 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-240v/)
- [Altenergy Power System Inc: ELS-96 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-208v/)
- [Altenergy Power System Inc: ELS-76 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-240v/)