Manufacturer: [**Altenergy Power System Inc**](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) Registry: **CEC Verified Engineering Specification**

Altenergy Power System Inc: ELS-76 {240V} outputs 7,609 W AC at 240 V (31.7 A continuous, 40 A OCPD), ranking #2,303 of 2,343 CEC inverters at 94.31% efficiency with a 51-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 7,609 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 40 A (8 AWG Cu)

- **CEC Efficiency** : 94.31%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Altenergy Power System Inc: ELS-76 {240V} Compare Against Peer CEC Listings?

Breaker sizing (40 A), 8 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: ELS-76 {240V}.

For NEC 705.12 solar interconnection, Altenergy Power System Inc: ELS-76 {240V} outputs 31.7 A continuous AC at 240 V and needs a 40 A backfeed breaker on 8 AWG Cu (75 C). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 94.31% (#2,303 of 2,343, -2.51 pts vs overall CEC median).

## Where Does Altenergy Power System Inc: ELS-76 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: ELS-76 {240V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Altenergy Power System Inc: ELS-76 {240V}?

Relative ranking of Altenergy Power System Inc: ELS-76 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Altenergy Power System Inc: ELS-76 {240V}?

Snapshot of Altenergy Power System Inc: ELS-76 {240V} efficiency rank (#2,303), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,303 / 2,343

### 94.31% CEC Weighted Efficiency

-2.37 pts vs the 96.68% 240 V median; overall power rank #1,215 (7,609 W, below CEC median; higher than 48.1% of peers).

NEC 705.12 Check

### 40 A Required Backfeed OCPD

125% x 31.7 A = 39.6 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 51 V - 60 V (Max 60 V DC)

Tracking span of 9.0 V; listed since 2025-01-13 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7609.0W / 240 V -> 31.7 A | Breaker >= 1.25 * 31.7 = 39.6 A -> 40 A

CEC Inverters.csv for Altenergy Power System Inc: ELS-76 {240V}: Paco=7609.0 W, Vac=240 V, Vdcmax=60.0 V, Eff=94.31%.

**Result:** Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Altenergy Power System Inc: ELS-76 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: ELS-76 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: ELS-76 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 7,609 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 60 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 51 V - 60 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 144.07 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 94.31% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-01-13 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Altenergy Power System Inc: ELS-76 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: ELS-76 {240V} at 240 V.

Evaluates Altenergy Power System Inc: ELS-76 {240V} (40 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 40 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 40 A | Needs Derate / Tap 705.11 |
| **200A Bus / 200A Main** | 40 A | 40 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 40 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 40 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Altenergy Power System Inc: ELS-76 {240V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: ELS-76 {240V} MPPT and 60 V limits.

Sampled CEC PV modules aligned within 51.0-60.0 V MPPT and 60.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: ELS-76 {240V}?

Peer 240 V CEC inverters near 7,609 W AC output such as ABB: UNO-76-TL-OUTD-S-US-A {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: UNO-76-TL-OUTD-S-US-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-76-tl-outd-s-us-a-240v/) ABB | 7,600 W | -9 W | 240.0 V | 480.0 V | 97.05% |
| [**ABB: UNO-76-TL-OUTD-S-US-Z-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-76-tl-outd-s-us-z-a-240v/) ABB | 7,600 W | -9 W | 240.0 V | 480.0 V | 97.05% |
| [**ABB: UNO-76-TL-OUTD-S-US-Z-M-A {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-76-tl-outd-s-us-z-m-a-240v/) ABB | 7,600 W | -9 W | 240.0 V | 480.0 V | 97.05% |
| [**Delta Electronics: SOLIVIA 76 NA G4 TL {240V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-solivia-76-na-g4-tl-240v/) Delta Electronics | 7,600 W | -9 W | 240.0 V | 500.0 V | 97.37% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: ELS-76 {240V}?

Check Altenergy Power System Inc: ELS-76 {240V} (7,609 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Altenergy Power System Inc: ELS-76 {240V}.

### Altenergy Power System Inc: ELS-76 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (94.31%) and MPPT window (51-60 V) directly against ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: ELS-76 {240V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Altenergy Power System Inc: ELS-76 {240V} require?

At 7,609 W continuous AC (240 V), continuous current is 31.7 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

### Does Altenergy Power System Inc: ELS-76 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

### How does Altenergy Power System Inc: ELS-76 {240V} compare to ABB: UNO-76-TL-OUTD-S-US-A {240V}?

Altenergy Power System Inc: ELS-76 {240V} delivers 7,609 W AC at 94.31% CEC efficiency with a 60 V DC ceiling, while ABB: UNO-76-TL-OUTD-S-US-A {240V} outputs 7,600 W at 240 V.

## Related Pages

Explore Altenergy Power System Inc hardware, ABB: UNO-76-TL-OUTD-S-US-A {240V}, utility rates, and NEC 705.12 sizing calculators alongside Altenergy Power System Inc: ELS-76 {240V}.

[All Altenergy Power System Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Altenergy Power System Inc

- [All Altenergy Power System Inc Specs](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/)
- [Altenergy Power System Inc: ELS-114 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/)
- [Altenergy Power System Inc: ELS-114 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-208v/)
- [Altenergy Power System Inc: ELS-96 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-240v/)
- [Altenergy Power System Inc: ELS-96 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-208v/)
- [Altenergy Power System Inc: ELS-76 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-208v/)