---
title: "Altenergy Power System Inc Inverter (6,606W)"
url: https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-208v/
description: "CEC specs for Altenergy Power System Inc: ELS-76 {208V}: 6,606W AC, 208V, 40A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Altenergy Power System Inc: ELS-76 {208V} — CEC Inverter Specifications

Manufacturer: [**Altenergy Power System Inc**](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) Registry: **CEC Verified Engineering Specification**

Altenergy Power System Inc: ELS-76 {208V} outputs 6,606 W AC at 208 V, commercial single-phase (31.8 A continuous, 40 A OCPD), ranking #2,317 of 2,343 CEC inverters at 93.96% efficiency with a 51-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 6,606 W

- **AC Voltage** : 208 V, commercial single-phase

- **Min PV Breaker** : 40 A (8 AWG Cu)

- **CEC Efficiency** : 93.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Altenergy Power System Inc: ELS-76 {208V} Compare Against Peer CEC Listings?

Breaker sizing (40 A), 8 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: ELS-76 {208V}.

Classified as a grid-tied PV inverter (listed since 2025-01-13), Altenergy Power System Inc: ELS-76 {208V} requires 39.8 A design capacity -> 40 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 93.96% (-2.86 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, commercial single-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

## Where Does Altenergy Power System Inc: ELS-76 {208V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: ELS-76 {208V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Altenergy Power System Inc: ELS-76 {208V}?

Relative ranking of Altenergy Power System Inc: ELS-76 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Altenergy Power System Inc: ELS-76 {208V}?

Snapshot of Altenergy Power System Inc: ELS-76 {208V} efficiency rank (#2,317), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,317 / 2,343

### 93.96% CEC Weighted Efficiency

-2.45 pts vs the 96.41% 208 V median; overall power rank #1,330 (6,606 W, below CEC median; higher than 43.2% of peers).

NEC 705.12 Check

### 40 A Required Backfeed OCPD

125% x 31.8 A = 39.8 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

### 51 V - 60 V (Max 60 V DC)

Tracking span of 9.0 V; listed since 2025-01-13 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6606.0W / 208 V -> 31.8 A | Breaker >= 1.25 * 31.8 = 39.8 A -> 40 A

CEC Inverters.csv for Altenergy Power System Inc: ELS-76 {208V}: Paco=6606.0 W, Vac=208 V, Vdcmax=60.0 V, Eff=93.96%.

**Result:** Min 40 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for Altenergy Power System Inc: ELS-76 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: ELS-76 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: ELS-76 {208V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 6,606 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 60 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 51 V - 60 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 125.551 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 93.96% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2025-01-13 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to Altenergy Power System Inc: ELS-76 {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: ELS-76 {208V} at 208 V, commercial single-phase.

Evaluates Altenergy Power System Inc: ELS-76 {208V} (40 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (208V)** | 40 A | 40 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (208V)** | 80 A | 40 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (208V)** | 120 A | 40 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (208V)** | 160 A | 40 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (208V)** | 240 A | 40 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With Altenergy Power System Inc: ELS-76 {208V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: ELS-76 {208V} MPPT and 60 V limits.

Sampled CEC PV modules aligned within 51.0-60.0 V MPPT and 60.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |

## Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: ELS-76 {208V}?

Peer 208 V, commercial single-phase CEC inverters near 6,606 W AC output such as Delta Electronics: SOLIVIA 66 NA G4 TL {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Delta Electronics: SOLIVIA 66 NA G4 TL {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-solivia-66-na-g4-tl-208v/) Delta Electronics | 6,600 W | -6 W | 208.0 V | 500.0 V | 97.02% |
| [**Delta Electronics: SOLIVIA 76 NA G4 TL {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-solivia-76-na-g4-tl-208v/) Delta Electronics | 6,600 W | -6 W | 208.0 V | 500.0 V | 97.02% |
| [**Delta Electronics: E8-TL-US {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-e8-tl-us-208v/) Delta Electronics | 6,656 W | +50 W | 208.0 V | 480.0 V | 97.21% |
| [**Delta Electronics: M8-TL-US {208V}**](https://epri-peac.com/solar-equipment/inverters/delta-electronics/delta-electronics-m8-tl-us-208v/) Delta Electronics | 6,660 W | +54 W | 208.0 V | 480.0 V | 97.23% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: ELS-76 {208V}?

Check Altenergy Power System Inc: ELS-76 {208V} (6,606 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Altenergy Power System Inc: ELS-76 {208V}.

### Altenergy Power System Inc: ELS-76 {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.8 A continuous).

### Alternative Inverter Comparison

Compare efficiency (93.96%) and MPPT window (51-60 V) directly against Delta Electronics: SOLIVIA 66 NA G4 TL {208V} (6,600 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: ELS-76 {208V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

### What breaker and wire size does Altenergy Power System Inc: ELS-76 {208V} require?

At 6,606 W continuous AC (208 V, commercial single-phase), continuous current is 31.8 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does Altenergy Power System Inc: ELS-76 {208V} require?

At 6,606 W AC and 208 V, commercial single-phase, continuous line current is 31.8 A, requiring a 40 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

### How does Altenergy Power System Inc: ELS-76 {208V} compare to Delta Electronics: SOLIVIA 66 NA G4 TL {208V}?

Altenergy Power System Inc: ELS-76 {208V} delivers 6,606 W AC at 93.96% CEC efficiency with a 60 V DC ceiling, while Delta Electronics: SOLIVIA 66 NA G4 TL {208V} outputs 6,600 W at 208 V, commercial single-phase.

## Related Pages

Explore Altenergy Power System Inc hardware, Delta Electronics: SOLIVIA 66 NA G4 TL {208V}, utility rates, and NEC 705.12 sizing calculators alongside Altenergy Power System Inc: ELS-76 {208V}.

[All Altenergy Power System Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Altenergy Power System Inc

- [All Altenergy Power System Inc Specs](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/)
- [Altenergy Power System Inc: ELS-114 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/)
- [Altenergy Power System Inc: ELS-114 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-208v/)
- [Altenergy Power System Inc: ELS-96 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-240v/)
- [Altenergy Power System Inc: ELS-96 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-208v/)
- [Altenergy Power System Inc: ELS-76 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-240v/)
