title: "Altenergy Power System Inc: DS3 Inverter (896W)"
url: https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-ds3-240v/
description: "CEC specs for Altenergy Power System Inc: DS3 {240V}: 896W AC, 240V, 15A OCPD, and NEC 705.12 checks. Verified US government and CEC engineering data."
---

CEC Grid-Support Inverter

# Altenergy Power System Inc: DS3 {240V} — CEC Inverter Specifications

Manufacturer: [**Altenergy Power System Inc**](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) Registry: **CEC Verified Engineering Specification**

Altenergy Power System Inc: DS3 {240V} outputs 896 W AC at 240 V (3.7 A continuous, 15 A OCPD), ranking #990 of 2,343 CEC inverters at 97.02% efficiency with a 36-43 V MPPT window and 43 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 896 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 97.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Altenergy Power System Inc: DS3 {240V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: DS3 {240V}.

Classified as a grid-tied PV inverter (listed since 2023-04-21), Altenergy Power System Inc: DS3 {240V} requires 4.6 A design capacity -> 15 A breaker using 14 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.02% (+0.20 pts vs overall CEC median) across 2,343 CEC models, while module-level microinverter output eliminates high-voltage dc rooftop strings and connects via a 240v ac trunk circuit.

## Where Does Altenergy Power System Inc: DS3 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: DS3 {240V} sits among all 2,343 CEC-listed grid-support inverters.

## What Dataset Percentiles Define Altenergy Power System Inc: DS3 {240V}?

Relative ranking of Altenergy Power System Inc: DS3 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

## What Do the Dataset Ranks Show for Altenergy Power System Inc: DS3 {240V}?

Snapshot of Altenergy Power System Inc: DS3 {240V} efficiency rank (#990), OCPD breaker size, MPPT span, and busbar verdict.

Eff #990 / 2,343

### 97.02% CEC Weighted Efficiency

+0.34 pts vs the 96.68% 240 V median; overall power rank #1,856 (896 W, below CEC median; higher than 20.7% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 3.7 A = 4.6 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 36 V - 43 V (Max 43 V DC)

Tracking span of 7.0 V; listed since 2023-04-21 (grid-tied PV inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 896.0W / 240 V -> 3.7 A | Breaker >= 1.25 * 3.7 = 4.6 A -> 15 A

CEC Inverters.csv for Altenergy Power System Inc: DS3 {240V}: Paco=896.0 W, Vac=240 V, Vdcmax=43.0 V, Eff=97.02%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for Altenergy Power System Inc: DS3 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: DS3 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: DS3 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 896 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 43 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 36 V - 43 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 23.6801 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.02% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2023-04-21 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## Can a Residential Panel Meet 120% Busbar Limits for Altenergy Power System Inc: DS3 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: DS3 {240V} at 240 V.

Evaluates Altenergy Power System Inc: DS3 {240V} (15 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 15 A | PASS (120% Rule) |
| **150A Bus / 150A Main** | 30 A | 15 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 15 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 15 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 15 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With Altenergy Power System Inc: DS3 {240V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: DS3 {240V} MPPT and 43 V limits.

Sampled CEC PV modules aligned within 36.0-43.0 V MPPT and 43.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-0-270tw/) | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |

## Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: DS3 {240V}?

Peer 240 V CEC inverters near 896 W AC output such as Anker Innovations Limited: MI80 {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Anker Innovations Limited: MI80 {240V}**](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80-240v/) Anker Innovations Limited | 896 W | Tie (0 W) | 240.0 V | 43.0 V | 97.02% |
| [**Cherry Solution Co Ltd: CMI-800S-SA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-800s-sa-240v/) Cherry Solution Co Ltd | 800 W | -96 W | 240.0 V | 50.0 V | 94.55% |
| [**Cherry Solution Co Ltd: CMI-800S-WA {240V}**](https://epri-peac.com/solar-equipment/inverters/cherry-solution-co-ltd/cherry-solution-co-ltd-cmi-800s-wa-240v/) Cherry Solution Co Ltd | 800 W | -96 W | 240.0 V | 50.0 V | 94.55% |
| [**Anker Innovations Limited: MI80L {240V}**](https://epri-peac.com/solar-equipment/inverters/anker-innovations-limited/anker-innovations-limited-mi80l-240v/) Anker Innovations Limited | 780 W | -116 W | 240.0 V | 43.0 V | 97.14% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: DS3 {240V}?

Check Altenergy Power System Inc: DS3 {240V} (896 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 43 V DC on Altenergy Power System Inc: DS3 {240V}.

### Altenergy Power System Inc: DS3 {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (3.7 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.02%) and MPPT window (36-43 V) directly against Anker Innovations Limited: MI80 {240V} (896 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: DS3 {240V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does Altenergy Power System Inc: DS3 {240V} require?

At 896 W continuous AC (240 V), continuous current is 3.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### Does Altenergy Power System Inc: DS3 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

### How does Altenergy Power System Inc: DS3 {240V} compare to Anker Innovations Limited: MI80 {240V}?

Altenergy Power System Inc: DS3 {240V} delivers 896 W AC at 97.02% CEC efficiency with a 43 V DC ceiling, while Anker Innovations Limited: MI80 {240V} outputs 896 W at 240 V.

## Related Pages

Explore Altenergy Power System Inc hardware, Anker Innovations Limited: MI80 {240V}, utility rates, and NEC 705.12 sizing calculators alongside Altenergy Power System Inc: DS3 {240V}.

[All Altenergy Power System Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Altenergy Power System Inc

- [All Altenergy Power System Inc Specs](https://epri-peac.com/solar-equipment/brands/altenergy-power-system-inc/)
- [Altenergy Power System Inc: ELS-114 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-240v/)
- [Altenergy Power System Inc: ELS-114 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-114-208v/)
- [Altenergy Power System Inc: ELS-96 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-240v/)
- [Altenergy Power System Inc: ELS-96 {208V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-96-208v/)
- [Altenergy Power System Inc: ELS-76 {240V}](https://epri-peac.com/solar-equipment/inverters/altenergy-power-system-inc/altenergy-power-system-inc-els-76-240v/)