CEC Grid-Support Inverter

# AIMS Power Inc: PIHY4600 {240V} — CEC Inverter Specifications

Manufacturer: [**AIMS Power Inc**](https://epri-peac.com/solar-equipment/brands/aims-power-inc/) Registry: **CEC Verified Engineering Specification**

AIMS Power Inc: PIHY4600 {240V} outputs 4,600 W AC at 240 V (19.2 A continuous, 25 A OCPD), ranking #429 of 2,343 CEC inverters at 97.79% efficiency with a 170-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 4,600 W

- **AC Voltage** : 240 V

- **Min PV Breaker** : 25 A (10 AWG Cu)

- **CEC Efficiency** : 97.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does AIMS Power Inc: PIHY4600 {240V} Compare Against Peer CEC Listings?

How AIMS Power Inc AIMS Power Inc: PIHY4600 {240V} compares on 97.79% efficiency, MPPT span, and 120% busbar interconnection.

With a 170-480 V MPPT tracking band and 480 V DC ceiling, AIMS Power Inc: PIHY4600 {240V} handles 4,600 W continuous AC (1,176 W below the 5,776 W 240 V median). Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing AIMS Power Inc against ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

## Where Does AIMS Power Inc: PIHY4600 {240V} Fall Across Listed CEC Models?

Position of AIMS Power Inc: PIHY4600 {240V} (4,600 W AC) relative to the 7,680 W CEC median inverter.

## What Dataset Percentiles Define AIMS Power Inc: PIHY4600 {240V}?

Percentile placement of AIMS Power Inc: PIHY4600 {240V} across AC power class, conversion efficiency, and backfeed breaker size.

## What Do the Dataset Ranks Show for AIMS Power Inc: PIHY4600 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for AIMS Power Inc: PIHY4600 {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Eff #429 / 2,343

### 97.79% CEC Weighted Efficiency

+1.11 pts vs the 96.68% 240 V median; overall power rank #1,581 (4,600 W, below CEC median; higher than 32.5% of peers).

NEC 705.12 Check

### 25 A Required Backfeed OCPD

125% x 19.2 A = 24.0 A -> 25 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

### 170 V - 480 V (Max 480 V DC)

Tracking span of 310.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

### PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4600.4W / 240 V -> 19.2 A | Breaker >= 1.25 * 19.2 = 24.0 A -> 25 A

CEC Inverters.csv for AIMS Power Inc: PIHY4600 {240V}: Paco=4600.4 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.79%.

**Result:** Min 25 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

## What Are the Published CEC Specifications for AIMS Power Inc: PIHY4600 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for AIMS Power Inc: PIHY4600 {240V}.

Official California Energy Commission (NREL SAM) test parameters for AIMS Power Inc: PIHY4600 {240V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 4,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 170 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 13.0679 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 97.79% | Calculated AC/DC conversion ratio from CEC test protocol |
| **Inverter Topology** | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |

## Can a Residential Panel Meet 120% Busbar Limits for AIMS Power Inc: PIHY4600 {240V}?

Check whether AIMS Power Inc: PIHY4600 {240V} (25 A breaker) fits without main breaker derate or supply-side taps.

Evaluates AIMS Power Inc: PIHY4600 {240V} (25 A required OCPD at 240 V) across standard distribution busbars.

| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **100A Bus / 100A Main** | 20 A | 25 A | Needs Derate / Tap 705.11 |
| **150A Bus / 150A Main** | 30 A | 25 A | PASS (120% Rule) |
| **200A Bus / 200A Main** | 40 A | 25 A | PASS (120% Rule) |
| **200A Bus / 175A Main** | 65 A | 25 A | PASS (120% Rule) |
| **225A Bus / 200A Main** | 70 A | 25 A | PASS (120% Rule) |

## Which CEC PV Module Strings Pair With AIMS Power Inc: PIHY4600 {240V}?

Verified cold-weather (-10 C) series module counts matched to AIMS Power Inc: PIHY4600 {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 170.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 5 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 6 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to AIMS Power Inc: PIHY4600 {240V}?

Alternative CEC inverters comparable to AIMS Power Inc: PIHY4600 {240V}, including ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-sb-ra-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| [**ABB: UNO-DM-46-TL-PLUS-US-SB-RA-Q {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-sb-ra-q-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| [**ABB: UNO-DM-46-TL-PLUS-US-SE-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-se-ra-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |
| [**ABB: UNO-DM-46-TL-PLUS-US-SZ-RA {240V}**](https://epri-peac.com/solar-equipment/inverters/abb/abb-uno-dm-46-tl-plus-us-sz-ra-240v/) ABB | 4,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.17% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for AIMS Power Inc: PIHY4600 {240V}?

Check AIMS Power Inc: PIHY4600 {240V} (4,600 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 25 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on AIMS Power Inc: PIHY4600 {240V}.

### AIMS Power Inc: PIHY4600 {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (19.2 A continuous).

### Alternative Inverter Comparison

Compare efficiency (97.79%) and MPPT window (170-480 V) directly against ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} (4,600 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for AIMS Power Inc: PIHY4600 {240V} by AIMS Power Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

### What breaker and wire size does AIMS Power Inc: PIHY4600 {240V} require?

At 4,600 W continuous AC (240 V), continuous current is 19.2 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.

### Does AIMS Power Inc: PIHY4600 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 25 A at 240 V means PASS (120% Rule).

### How does AIMS Power Inc: PIHY4600 {240V} compare to ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}?

AIMS Power Inc: PIHY4600 {240V} delivers 4,600 W AC at 97.79% CEC efficiency with a 480 V DC ceiling, while ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V} outputs 4,600 W at 240 V.

## Related Pages

Explore AIMS Power Inc hardware, ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V}, utility rates, and NEC 705.12 sizing calculators alongside AIMS Power Inc: PIHY4600 {240V}.

[All AIMS Power Inc Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/aims-power-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
