CEC Grid-Support Inverter

# ABB: PVI-36-OUTD-S-US-Z-M-A {277V} — CEC Inverter Specifications

Manufacturer: [**ABB**](https://epri-peac.com/solar-equipment/brands/abb/) Registry: **CEC Verified Engineering Specification**

ABB: PVI-36-OUTD-S-US-Z-M-A {277V} outputs 3,600 W AC at 480Y/277 V, 3-phase (4.3 A continuous, 15 A OCPD), ranking #1,297 of 2,343 CEC inverters at 96.67% efficiency with a 100-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **AC Output (Paco)** : 3,600 W

- **AC Voltage** : 480Y/277 V, 3-phase

- **Min PV Breaker** : 15 A (14 AWG Cu)

- **CEC Efficiency** : 96.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does ABB: PVI-36-OUTD-S-US-Z-M-A {277V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,297), 100-480 V MPPT tracking, and panel fit for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

ABB: PVI-36-OUTD-S-US-Z-M-A {277V} from ABB outputs 4.3 A continuous AC at 480Y/277 V, 3-phase (3,600 W AC, rank #1,685). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.67% CEC efficiency compares closely with Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W). Keep NEC 690.7 winter string Voc below 480 V DC.

## Where Does ABB: PVI-36-OUTD-S-US-Z-M-A {277V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting ABB: PVI-36-OUTD-S-US-Z-M-A {277V} at 3,600 W continuous AC output. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define ABB: PVI-36-OUTD-S-US-Z-M-A {277V}?

Dataset percentiles comparing ABB: PVI-36-OUTD-S-US-Z-M-A {277V} against 2,343 certified grid-support inverters nationwide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Do the Dataset Ranks Show for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}?

Engineering highlights for ABB: PVI-36-OUTD-S-US-Z-M-A {277V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #1,297 / 2,343

### 96.67% CEC Weighted Efficiency

-0.15 pts vs the 96.82% 277 V median; overall power rank #1,685 (3,600 W, below CEC median; higher than 27.6% of peers).

NEC 705.12 Check

### 15 A Required Backfeed OCPD

125% x 4.3 A = 5.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

### 100 V - 480 V (Max 480 V DC)

Tracking span of 380.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

### PASS (120% Commercial Busbar)

Evaluated for 480Y/277 V, 3-phase switchgear (200A Bus / 200A Main (277V) to 1,200A Bus / 1,200A Main (277V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3600.0W / 480 V 3-phase -> 4.3 A | Breaker >= 1.25 * 4.3 = 5.4 A -> 15 A

CEC Inverters.csv for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}: Paco=3600.0 W, Vac=277 V, Vdcmax=480.0 V, Eff=96.67%.

**Result:** Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (277V): PASS (120% Commercial Busbar).

## What Are the Published CEC Specifications for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}?

California Energy Commission Solar Equipment List parameters for ABB: PVI-36-OUTD-S-US-Z-M-A {277V} (grid-tied PV inverter) interconnection. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Max Continuous AC Power (Paco)** | 3,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| **Nominal AC Voltage (Vac)** | 480Y/277 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| **Max DC Input Voltage (Vdcmax)** | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| **MPPT Operating Range** | 100 V - 480 V | Optimal DC string Vmp window for full power harvest |
| **Max Input DC Current (Idcmax)** | 9.42832 A | Used to verify parallel string combiner limits |
| **CEC Weighted Efficiency** | 96.67% | Calculated AC/DC conversion ratio from CEC test protocol |
| **CEC Listing Date & Hybrid** | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |

## What Switchgear Limits Apply to ABB: PVI-36-OUTD-S-US-Z-M-A {277V} (480Y/277 V, 3-phase)?

Panelboard and switchgear backfeed allowances for ABB: PVI-36-OUTD-S-US-Z-M-A {277V} (15 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates ABB: PVI-36-OUTD-S-US-Z-M-A {277V} (15 A required OCPD at 480Y/277 V, 3-phase) across standard distribution busbars.

| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| **200A Bus / 200A Main (277V)** | 40 A | 15 A | PASS (120% Commercial Busbar) |
| **400A Bus / 400A Main (277V)** | 80 A | 15 A | PASS (120% Commercial Busbar) |
| **600A Bus / 600A Main (277V)** | 120 A | 15 A | PASS (120% Commercial Busbar) |
| **800A Bus / 800A Main (277V)** | 160 A | 15 A | PASS (120% Commercial Busbar) |
| **1,200A Bus / 1,200A Main (277V)** | 240 A | 15 A | PASS (120% Commercial Busbar) |

## Which CEC PV Module Strings Pair With ABB: PVI-36-OUTD-S-US-Z-M-A {277V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 100.0-480.0 V MPPT and 480.0 V max DC at -10 C.

| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| [**AXITEC AC-590TGB/144TS**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-590tgb-144ts/) | 590.0 W | 56.24 V | 3 to 8 panels | 4.72 kW |
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) | 440.0 W | 42.15 V | 3 to 11 panels | 4.84 kW |
| [**Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-425-h-hc-bf/) | 425.0 W | 44.75 V | 3 to 10 panels | 4.25 kW |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) | 200.0 W | 40.6 V | 4 to 11 panels | 2.2 kW |

## Which Competing Grid-Support Inverters Compare to ABB: PVI-36-OUTD-S-US-Z-M-A {277V}?

Four alternative CEC inverters matched to ABB: PVI-36-OUTD-S-US-Z-M-A {277V} (3,600 W AC), led by Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}.

Alternative CEC inverters at comparable AC output power and voltage class.

| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| [**Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}**](https://epri-peac.com/solar-equipment/inverters/shenzhen-growatt-new-energy-co-ltd/shenzhen-growatt-new-energy-co-ltd-growatt-4000mtlp-us-277v/) Shenzhen Growatt New Energy Co Ltd | 4,060 W | +460 W | 277.0 V | 550.0 V | 97.23% |
| [**Shenzhen Growatt New Energy Co Ltd: GROWATT 5000MTLP-US {277V}**](https://epri-peac.com/solar-equipment/inverters/shenzhen-growatt-new-energy-co-ltd/shenzhen-growatt-new-energy-co-ltd-growatt-5000mtlp-us-277v/) Shenzhen Growatt New Energy Co Ltd | 5,060 W | +1460 W | 277.0 V | 550.0 V | 97.1% |
| [**Shenzhen Growatt New Energy Co Ltd: GROWATT 6000MTLP-US {277V}**](https://epri-peac.com/solar-equipment/inverters/shenzhen-growatt-new-energy-co-ltd/shenzhen-growatt-new-energy-co-ltd-growatt-6000mtlp-us-277v/) Shenzhen Growatt New Energy Co Ltd | 6,080 W | +2480 W | 277.0 V | 550.0 V | 97.0% |
| [**Northern Electric & Power Co Ltd: BDM-800-277A {277V}**](https://epri-peac.com/solar-equipment/inverters/northern-electric-power-co-ltd/northern-electric-power-co-ltd-bdm-800-277a-277v/) Northern Electric & Power Co Ltd | 799 W | -2801 W | 277.0 V | 55.0 V | 96.31% |

What to Check & Best-Fit Scenarios

## What Are the Interconnection Limits and Best-Fit Uses for ABB: PVI-36-OUTD-S-US-Z-M-A {277V}?

Check ABB: PVI-36-OUTD-S-US-Z-M-A {277V} (3,600 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480Y/277 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (277V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: PVI-36-OUTD-S-US-Z-M-A {277V}.

### ABB: PVI-36-OUTD-S-US-Z-M-A {277V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.3 A continuous).

### Alternative Inverter Comparison

Compare efficiency (96.67%) and MPPT window (100-480 V) directly against Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} (4,060 W).

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for ABB: PVI-36-OUTD-S-US-Z-M-A {277V} by ABB covering breaker sizing, MPPT limits, and 480Y/277 V, 3-phase interconnection.

### What breaker and wire size does ABB: PVI-36-OUTD-S-US-Z-M-A {277V} require?

At 3,600 W continuous AC (480Y/277 V, 3-phase), continuous current is 4.3 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

### What commercial switchgear or feeder sizing does ABB: PVI-36-OUTD-S-US-Z-M-A {277V} require?

At 3,600 W AC and 480Y/277 V, 3-phase, continuous line current is 4.3 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (277V) or NEC 705.11 interconnection.

### How does ABB: PVI-36-OUTD-S-US-Z-M-A {277V} compare to Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}?

ABB: PVI-36-OUTD-S-US-Z-M-A {277V} delivers 3,600 W AC at 96.67% CEC efficiency with a 480 V DC ceiling, while Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V} outputs 4,060 W at 480Y/277 V, 3-phase.

## Related Pages

Explore ABB hardware, Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V}, utility rates, and NEC 705.12 sizing calculators alongside ABB: PVI-36-OUTD-S-US-Z-M-A {277V}.

[All ABB Certified Solar Hardware](https://epri-peac.com/solar-equipment/brands/abb/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Check NEC 705.12 120% Busbar Capacity Calculator](https://epri-peac.com/tools/solar-busbar-120/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From ABB

- [All ABB Specs](https://epri-peac.com/solar-equipment/brands/abb/)
- [ABB: PVS-175-TL-POWER-MODULE-1-US {800V}](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-175-tl-power-module-1-us-800v/)
- [ABB: PVS-175-TL-POWER-MODULE-2-US {800V}](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-175-tl-power-module-2-us-800v/)
- [ABB: PVS-166-TL-POWER-MODULE-1-US {800V}](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-166-tl-power-module-1-us-800v/)
- [ABB: PVS-166-TL-POWER-MODULE-2-US {800V}](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-166-tl-power-module-2-us-800v/)
- [ABB: PVS-60-TL-R-US {480V}](https://epri-peac.com/solar-equipment/inverters/abb/abb-pvs-60-tl-r-us-480v/)