title: "Your Energy Solutions Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/your-energy-solutions/
description: "CEC datasheets for Your Energy Solutions: 405–455W PV, 3 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Your Energy Solutions — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Your Energy Solutions holds 3 verified California Energy Commission (CEC) certifications including 3 module series (405–455W PV). Your Energy Solutions carries 3 module series ranging from 405 W to 455 W STC (median 435 W vs 385 W CEC fleet median; 22.3% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Your Energy Solutions

- **PV Module Series** : 3

- **Listed Inverters** : 0

- **Output Range** : 405–455W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Your Energy Solutions Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for Your Energy Solutions.

Your Energy Solutions participates in the California Energy Commission (CEC) Solar Equipment List with 3 total certified hardware listings. Your Energy Solutions carries 3 module series ranging from 405 W to 455 W STC (median 435 W vs 385 W CEC fleet median; 22.3% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match Your Energy Solutions in our federal recall archive as of 2026.

## Which Your Energy Solutions PV Module Series Are CEC Certified? (3)

Filter certified Your Energy Solutions solar panels by series name, nameplate STC capacity, PTC output, open-circuit voltage, or conversion efficiency.

Filter Your Energy Solutions Modules

Deduplicated CEC photovoltaic module series for Your Energy Solutions.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Your Energy Solutions YES-NBF108-455W**](https://epri-peac.com/solar-equipment/modules/your-energy-solutions/your-energy-solutions-yes-nbf108-455w/) | 455.0 | 431.9 | 39.02 | 23.33 | 2 |
| [**Your Energy Solutions YES-NBF108-435W**](https://epri-peac.com/solar-equipment/modules/your-energy-solutions/your-energy-solutions-yes-nbf108-435w/) | 435.0 | 412.5 | 38.5 | 22.31 | 5 |
| [**Your Energy Solutions YES-BF405W-BLK**](https://epri-peac.com/solar-equipment/modules/your-energy-solutions/your-energy-solutions-yes-bf405w-blk/) | 405.0 | 381.3 | 37.4 | 20.98 | 3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Your Energy Solutions Solar Hardware?

Evaluate Your Energy Solutions CEC certifications (405–455W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Your Energy Solutions certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Your Energy Solutions Module + Third-Party Inverter

Pair Your Energy Solutions modules (405–455W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Your Energy Solutions photovoltaic and inverter hardware listed on the CEC registry.

### How many Your Energy Solutions solar models are verified on the CEC list?

Our CEC archive indexes 3 Your Energy Solutions equipment records (3 module series and 0 inverter models) spanning 405–455W PV. Check local building department permit requirements for Your Energy Solutions before finalizing component orders.

### What should homeowners check before approving Your Energy Solutions equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Your Energy Solutions solar panels compared to CEC averages?

Across listed series, Your Energy Solutions modules show a median aperture efficiency of 22.3% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Your Energy Solutions.

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to Your Energy Solutions.

[Ablytek CEC Solar Catalog (270–285W PV)](https://epri-peac.com/solar-equipment/brands/ablytek/) [AIMS Power Inc CEC Solar Catalog (4,600–9,592W AC)](https://epri-peac.com/solar-equipment/brands/aims-power-inc/) [Tabuchi Electric Co Ltd CEC Solar Catalog (5,518W AC)](https://epri-peac.com/solar-equipment/brands/tabuchi-electric-co-ltd/) [Anhui Rinengzhongtian Semiconductor Development Co Ltd CEC Solar Catalog (340–360W PV)](https://epri-peac.com/solar-equipment/brands/anhui-rinengzhongtian-semiconductor-development-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)