title: "Univix Power Solutions Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/univix-power-solutions/
description: "CEC datasheets for Univix Power Solutions: 5,000–16,000W AC, 0 module series, 7 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Univix Power Solutions — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Univix Power Solutions holds 7 verified California Energy Commission (CEC) certifications and 7 grid-support inverter models (5,000–16,000W AC). On the AC conversion side, Univix Power Solutions lists 7 CEC-certified inverters from 5,000 W to 16,000 W AC (97.1% median weighted CEC efficiency, including 7 battery-ready hybrid units). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Univix Power Solutions

- **PV Module Series** : 0

- **Listed Inverters** : 7

- **Output Range** : 5,000–16,000W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Univix Power Solutions Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Univix Power Solutions photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Univix Power Solutions hardware for residential interconnection can verify exact DC and AC test data across 7 CEC records. On the AC conversion side, Univix Power Solutions lists 7 CEC-certified inverters from 5,000 W to 16,000 W AC (97.1% median weighted CEC efficiency, including 7 battery-ready hybrid units). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match Univix Power Solutions in our federal recall archive as of 2026.

## Which Univix Power Solutions Grid-Support Inverters Are Listed? (7)

Filter Univix Power Solutions inverters approved for utility interconnection across 240V split-phase residential and 208V/480V commercial electrical services.

Filter Univix Power Solutions Inverters

Verified CEC grid-support inverters from Univix Power Solutions.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Univix Power Solutions: UVX16LNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx16lna-240v/) | 16,000 | 240.0 | 430.0 | 96.26 |
| [**Univix Power Solutions: UVX12KLNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx12klna-240v/) | 12,000 | 240.0 | 430.0 | 96.2 |
| [**Univix Power Solutions: UVX10KLNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx10klna-240v/) | 10,000 | 240.0 | 430.0 | 97.16 |
| [**Univix Power Solutions: UVX8KLNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx8klna-240v/) | 8,000 | 240.0 | 430.0 | 97.1 |
| [**Univix Power Solutions: UVX76KLNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx76klna-240v/) | 7,600 | 240.0 | 430.0 | 97.16 |
| [**Univix Power Solutions: UVX6KLNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx6klna-240v/) | 6,000 | 240.0 | 430.0 | 97.15 |
| [**Univix Power Solutions: UVX5KLNA {240V}**](https://epri-peac.com/solar-equipment/inverters/univix-power-solutions/univix-power-solutions-uvx5klna-240v/) | 5,000 | 240.0 | 430.0 | 97.02 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Univix Power Solutions Solar Hardware?

Evaluate Univix Power Solutions CEC certifications (5,000–16,000W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Univix Power Solutions supplies 7 inverter models on the CEC list; cold-climate roofs must check string Voc rise against the inverter's Vdcmax limit before finalizing module count.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Univix Power Solutions AC Conversion (5,000–16,000W AC)

Match Univix Power Solutions MPPT channels and Vdcmax ceilings to third-party CEC panels, verifying NEC 705.12 120% panel busbar limits.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Univix Power Solutions photovoltaic and inverter hardware listed on the CEC registry.

### How many Univix Power Solutions solar models are verified on the CEC list?

Our CEC archive indexes 7 Univix Power Solutions equipment records (0 module series and 7 inverter models) spanning 5,000–16,000W AC. Check local building department permit requirements for Univix Power Solutions before finalizing component orders.

### What should homeowners check before approving Univix Power Solutions equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to Univix Power Solutions.

[Anker Innovations Limited CEC Solar Catalog (656–7,687W AC)](https://epri-peac.com/solar-equipment/brands/anker-innovations-limited/) [Changzhou EGing Photovoltaic Technology Co Ltd CEC Solar Catalog (395–555W PV)](https://epri-peac.com/solar-equipment/brands/changzhou-eging-photovoltaic-technology-co-ltd/) [Tata Power Renewables CEC Solar Catalog (520–610W PV)](https://epri-peac.com/solar-equipment/brands/tata-power-renewables/) [Energate Energy Inc CEC Solar Catalog (395–550W PV)](https://epri-peac.com/solar-equipment/brands/energate-energy-inc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)