---
title: "United Energy Co Ltd Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/united-energy-co-ltd/
description: "CEC datasheets for United Energy Co Ltd: 440–560W PV, 5 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# United Energy Co Ltd — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

United Energy Co Ltd holds 5 verified California Energy Commission (CEC) certifications including 5 module series (440–560W PV). United Energy Co Ltd carries 5 module series ranging from 440 W to 560 W STC (median 520 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : United Energy Co Ltd

- **PV Module Series** : 5

- **Listed Inverters** : 0

- **Output Range** : 440–560W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do United Energy Co Ltd Solar Specifications Compare Across the CEC Catalog?

How United Energy Co Ltd residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying United Energy Co Ltd for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). United Energy Co Ltd carries 5 module series ranging from 440 W to 560 W STC (median 520 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si). CPSC cross-check notes 1 federal electrical recall referencing United Energy Co Ltd — United Copper Recalls Metal Clad Cables Due to Fire and Shock Hazards; confirm serial-number status prior to installation.

## Which United Energy Co Ltd PV Module Series Are CEC Certified? (5)

Every deduplicated United Energy Co Ltd solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter United Energy Co Ltd Modules

Deduplicated CEC photovoltaic module series for United Energy Co Ltd.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**United Energy Co Ltd UE560M-72HB**](https://epri-peac.com/solar-equipment/modules/united-energy-co-ltd/united-energy-co-ltd-ue560m-72hb/) | 560.0 | 526.8 | 50.0 | 21.71 | 5 |
| [**United Energy Co Ltd UE540M-72HB**](https://epri-peac.com/solar-equipment/modules/united-energy-co-ltd/united-energy-co-ltd-ue540m-72hb/) | 540.0 | 507.6 | 49.6 | 20.93 | 4 |
| [**United Energy Co Ltd UE520M-72HB**](https://epri-peac.com/solar-equipment/modules/united-energy-co-ltd/united-energy-co-ltd-ue520m-72hb/) | 520.0 | 488.3 | 49.2 | 20.16 | 1 |
| [**United Energy Co Ltd UE460M-72HB**](https://epri-peac.com/solar-equipment/modules/united-energy-co-ltd/united-energy-co-ltd-ue460m-72hb/) | 460.0 | 428.2 | 50.4 | 21.2 | 5 |
| [**United Energy Co Ltd UE440M-72HB**](https://epri-peac.com/solar-equipment/modules/united-energy-co-ltd/united-energy-co-ltd-ue440m-72hb/) | 440.0 | 409.1 | 49.6 | 20.28 | 3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for United Energy Co Ltd Solar Hardware?

Evaluate United Energy Co Ltd CEC certifications (440–560W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- United Energy Co Ltd certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### United Energy Co Ltd Module + Third-Party Inverter

Pair United Energy Co Ltd modules (440–560W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring United Energy Co Ltd solar modules or inverters. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

### How many United Energy Co Ltd solar models are verified on the CEC list?

Our CEC archive indexes 5 United Energy Co Ltd equipment records (5 module series and 0 inverter models) spanning 440–560W PV. Check local building department permit requirements for United Energy Co Ltd before finalizing component orders.

### What should homeowners check before approving United Energy Co Ltd equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are United Energy Co Ltd solar panels compared to CEC averages?

Across listed series, United Energy Co Ltd modules show a median aperture efficiency of 20.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting United Energy Co Ltd.

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to United Energy Co Ltd.

[Yingli Energy Development Co Ltd CEC Solar Catalog (400–555W PV)](https://epri-peac.com/solar-equipment/brands/yingli-energy-development-co-ltd/) [AE Solar GmbH CEC Solar Catalog (420–585W PV)](https://epri-peac.com/solar-equipment/brands/ae-solar-gmbh/) [T-Solar Global CEC Solar Catalog (97–410W PV)](https://epri-peac.com/solar-equipment/brands/t-solar-global/) [Alexus Solar CEC Solar Catalog (405–550W PV)](https://epri-peac.com/solar-equipment/brands/alexus-solar/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
