title: "Tesla Inc Solar Panels & Inverters (23 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/tesla-inc/
description: "CEC datasheets for Tesla Inc: 23–430W PV / 3,336–11,508W AC, 17 module series, 6 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Tesla Inc — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Tesla Inc holds 23 verified California Energy Commission (CEC) certifications including 17 module series and 6 grid-support inverter models (23–430W PV / 3,336–11,508W AC). Tesla Inc carries 17 module series ranging from 23 W to 430 W STC (median 73 W vs 385 W CEC fleet median; 16.2% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si).

- **Manufacturer** : Tesla Inc

- **PV Module Series** : 17

- **Listed Inverters** : 6

- **Output Range** : 23–430W PV / 3,336–11,508W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Tesla Inc Solar Specifications Compare Across the CEC Catalog?

How Tesla Inc residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Tesla Inc for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Tesla Inc carries 17 module series ranging from 23 W to 430 W STC (median 73 W vs 385 W CEC fleet median; 16.2% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). On the AC conversion side, Tesla Inc lists 6 CEC-certified inverters from 3,336 W to 11,508 W AC (97.4% median weighted CEC efficiency, including 2 battery-ready hybrid units). No active CPSC electrical recalls match Tesla Inc in our federal recall archive as of 2026.

## Which Tesla Inc PV Module Series Are CEC Certified? (17)

Inspect Tesla Inc photovoltaic panel series sorted from highest STC wattage downward; near-identical wattage trims are grouped inside each series page.

Filter Tesla Inc Modules

Deduplicated CEC photovoltaic module series for Tesla Inc.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Tesla Inc T430S**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t430s/) | 430.0 | 401.8 | 48.8 | 20.37 | 2 |
| [**Tesla Inc TSP-430**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-430/) | 430.0 | 405.0 | 41.01 | 21.18 | 2 |
| [**Tesla Inc T420S**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t420s/) | 420.0 | 392.2 | 48.5 | 19.9 | 1 |
| [**Tesla Inc TSP-415**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-415/) | 415.0 | 390.6 | 40.92 | 20.44 | 4 |
| [**Tesla Inc T400H**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t400h/) | 400.0 | 371.5 | 45.3 | 20.83 | 3 |
| [**Tesla Inc T395H**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t395h/) | 395.0 | 366.7 | 45.27 | 20.57 | 1 |
| [**Tesla Inc SR86T3R**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr86t3r/) | 86.0 | 77.3 | 26.6 | 17.92 | 1 |
| [**Tesla Inc SR75T3R**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr75t3r/) | 75.0 | 67.9 | 14.2 | 16.67 | 1 |
| [**Tesla Inc SR73T3R**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr73t3r/) | 73.0 | 66.0 | 14.2 | 16.22 | 1 |
| [**Tesla Inc SR72T1**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr72t1/) | 72.0 | 65.4 | 14.2 | 14.69 | 1 |
| [**Tesla Inc SR72T2**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr72t2/) | 72.0 | 65.4 | 14.2 | 14.69 | 1 |
| [**Tesla Inc SR72T3R**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr72t3r/) | 72.0 | 65.4 | 14.2 | 14.69 | 1 |
| [**Tesla Inc SR60T1**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr60t1/) | 58.5 | 52.1 | 13.34 | 11.93 | 1 |
| [**Tesla Inc SR25S3**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr25s3/) | 25.0 | 22.3 | 4.3 | 10.58 | 1 |
| [**Tesla Inc SR25T3**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr25t3/) | 25.0 | 21.9 | 4.3 | 10.56 | 1 |
| [**Tesla Inc SR24S3-2**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr24s3-2/) | 23.8 | 20.5 | 3.8 | 9.9 | 1 |
| [**Tesla Inc SR24T3-2**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr24t3-2/) | 23.8 | 20.5 | 3.8 | 9.9 | 1 |

## Which Tesla Inc Grid-Support Inverters Are Listed? (6)

Compare CEC-certified Tesla Inc inverters by continuous AC output watts, nominal grid voltage, maximum DC input ceiling, and weighted test efficiency.

Filter Tesla Inc Inverters

Verified CEC grid-support inverters from Tesla Inc.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Tesla Inc: 1707000-XX-Y {240V 115kW}**](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1707000-xx-y-240v-115kw/) | 11,508 | 240.0 | 480.0 | 97.19 |
| [**Tesla Inc: 1707000-XX-Y {240V 10kW}**](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1707000-xx-y-240v-10kw/) | 9,991 | 240.0 | 480.0 | 95.82 |
| [**Tesla Inc: 1538000-xx-y {240V}**](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1538000-xx-y-240v/) | 7,575 | 240.0 | 480.0 | 97.54 |
| [**Tesla Inc: 1538000-xx-y {208V}**](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1538000-xx-y-208v/) | 6,561 | 208.0 | 480.0 | 97.37 |
| [**Tesla Inc: 1534000-xx-y {240V}**](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1534000-xx-y-240v/) | 3,800 | 240.0 | 425.0 | 97.61 |
| [**Tesla Inc: 1534000-xx-y {208V}**](https://epri-peac.com/solar-equipment/inverters/tesla-inc/tesla-inc-1534000-xx-y-208v/) | 3,336 | 208.0 | 480.0 | 97.42 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Tesla Inc Solar Hardware?

Evaluate Tesla Inc CEC certifications (23–430W PV / 3,336–11,508W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- With 17 module series and 6 inverter models, verify your exact wattage trim appears on your utility's accepted CEC sub-revision before permitting.
- Constrained roofs: Tesla Inc's median module aperture efficiency (16.2%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Unified Tesla Inc Solar + Inverter Spec

Use Tesla Inc modules and inverters together under unified CEC certification tracking while verifying NEC 705.12 backfeed clearance.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Tesla Inc solar equipment. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

### How many Tesla Inc solar models are verified on the CEC list?

Our CEC archive indexes 23 Tesla Inc equipment records (17 module series and 6 inverter models) spanning 23–430W PV / 3,336–11,508W AC. Check local building department permit requirements for Tesla Inc before finalizing component orders.

### What should homeowners check before approving Tesla Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Tesla Inc solar panels compared to CEC averages?

Across listed series, Tesla Inc modules show a median aperture efficiency of 16.2% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[US Solar CEC Solar Catalog (140–330W PV)](https://epri-peac.com/solar-equipment/brands/us-solar/) [Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd CEC Solar Catalog (245–450W PV)](https://epri-peac.com/solar-equipment/brands/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/) [Renesola America CEC Solar Catalog (250–330W PV)](https://epri-peac.com/solar-equipment/brands/renesola-america/) [BYD Company Limited CEC Solar Catalog (235–660W PV)](https://epri-peac.com/solar-equipment/brands/byd-company-limited/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)