title: "Sunrise Solartech Solar Panels and Inverters (12 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/sunrise-solartech/
description: "CEC datasheets for Sunrise Solartech: 220–310W PV, 12 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Sunrise Solartech — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Sunrise Solartech holds 12 verified California Energy Commission (CEC) certifications including 12 module series (220–310W PV). Sunrise Solartech carries 12 module series ranging from 220 W to 310 W STC (median 278 W vs 385 W CEC fleet median; 14.6% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Sunrise Solartech

- **PV Module Series** : 12

- **Listed Inverters** : 0

- **Output Range** : 220–310W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Sunrise Solartech Solar Specifications Compare Across the CEC Catalog?

Technical overview of Sunrise Solartech solar certifications used by municipal inspectors and utilities to approve residential rooftop permits.

Independent third-party test metrics from the CEC confirm electrical ratings for Sunrise Solartech hardware under UL 1703/61730 and IEEE 1547 utility protocols. Typical PVUSA (PTC) real-world thermal output retains 88.8% of nameplate STC watts. Sunrise Solartech carries 12 module series ranging from 220 W to 310 W STC (median 278 W vs 385 W CEC fleet median; 14.6% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). No active CPSC electrical recalls match Sunrise Solartech in our federal recall archive as of 2026.

## Which Sunrise Solartech PV Module Series Are CEC Certified? (12)

Filter certified Sunrise Solartech solar panels by series name, nameplate STC capacity, PTC output, open-circuit voltage, or conversion efficiency.

Filter Sunrise Solartech Modules

Deduplicated CEC photovoltaic module series for Sunrise Solartech.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Sunrise Solartech SR-M672310**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-m672310/) | 310.0 | 271.6 | 44.77 | 15.96 | 1 |
| [**Sunrise Solartech SR-M672305**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-m672305/) | 305.0 | 267.1 | 44.53 | 15.7 | 1 |
| [**Sunrise Solartech SR-P672295**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672295/) | 295.0 | 262.4 | 43.77 | 15.19 | 1 |
| [**Sunrise Solartech SR-P672290**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672290/) | 290.0 | 257.8 | 43.52 | 14.93 | 1 |
| [**Sunrise Solartech SR-P672285**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672285/) | 285.0 | 253.3 | 43.4 | 14.67 | 1 |
| [**Sunrise Solartech SR-P672280**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672280/) | 280.0 | 248.7 | 43.08 | 14.42 | 1 |
| [**Sunrise Solartech SR-P672275**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672275/) | 275.0 | 244.1 | 42.61 | 14.16 | 1 |
| [**Sunrise Solartech SR-P660240**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p660240/) | 240.0 | 213.3 | 36.46 | 14.78 | 1 |
| [**Sunrise Solartech SR-P660235**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p660235/) | 235.0 | 208.7 | 36.21 | 14.47 | 1 |
| [**Sunrise Solartech SR-P660230**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p660230/) | 230.0 | 204.2 | 35.84 | 14.16 | 1 |
| [**Sunrise Solartech SR-P660225**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p660225/) | 225.0 | 199.6 | 35.46 | 13.86 | 1 |
| [**Sunrise Solartech SR-P660220**](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p660220/) | 220.0 | 195.1 | 35.07 | 13.55 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Sunrise Solartech Solar Hardware?

Evaluate Sunrise Solartech CEC certifications (220–310W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Sunrise Solartech certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Sunrise Solartech's median module aperture efficiency (14.6%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Sunrise Solartech Module + Third-Party Inverter

Pair Sunrise Solartech modules (220–310W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering Sunrise Solartech CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

### How many Sunrise Solartech solar models are verified on the CEC list?

Our CEC archive indexes 12 Sunrise Solartech equipment records (12 module series and 0 inverter models) spanning 220–310W PV. Check local building department permit requirements for Sunrise Solartech before finalizing component orders.

### What should homeowners check before approving Sunrise Solartech equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Sunrise Solartech solar panels compared to CEC averages?

Across listed series, Sunrise Solartech modules show a median aperture efficiency of 14.6% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Sunrise Solartech.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[WINAICO CEC Solar Catalog (235–335W PV)](https://epri-peac.com/solar-equipment/brands/winaico/) [AMPS Solar CEC Solar Catalog (395–600W PV)](https://epri-peac.com/solar-equipment/brands/amps-solar/) [Mitrex CEC Solar Catalog (295–440W PV)](https://epri-peac.com/solar-equipment/brands/mitrex/) [Flextronics CEC Solar Catalog (252–340W PV)](https://epri-peac.com/solar-equipment/brands/flextronics/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)