---
title: "SunEvo Solar Co Ltd Solar Panels and Inverters (5 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/sunevo-solar-co-ltd/
description: "CEC datasheets for SunEvo Solar Co Ltd: 440–560W PV, 5 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# SunEvo Solar Co Ltd — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

SunEvo Solar Co Ltd holds 5 verified California Energy Commission (CEC) certifications including 5 module series (440–560W PV). SunEvo Solar Co Ltd carries 5 module series ranging from 440 W to 560 W STC (median 520 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : SunEvo Solar Co Ltd

- **PV Module Series** : 5

- **Listed Inverters** : 0

- **Output Range** : 440–560W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do SunEvo Solar Co Ltd Solar Specifications Compare Across the CEC Catalog?

Independent datasheet aggregation for SunEvo Solar Co Ltd across 5 certified listings, highlighting wattage coverage, PTC retention, and inverter topology.

CEC engineering compliance records for SunEvo Solar Co Ltd cover 5 module series and 0 inverter models. SunEvo Solar Co Ltd carries 5 module series ranging from 440 W to 560 W STC (median 520 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si). Across tested modules, median efficiency of 20.9% runs 1.0 percentage points above the 19.91% CEC benchmark. No active CPSC electrical recalls match SunEvo Solar Co Ltd in our federal recall archive as of 2026.

## Which SunEvo Solar Co Ltd PV Module Series Are CEC Certified? (5)

Every deduplicated SunEvo Solar Co Ltd solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter SunEvo Solar Co Ltd Modules

Deduplicated CEC photovoltaic module series for SunEvo Solar Co Ltd.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**SunEvo Solar Co Ltd SE5-72H-560MB**](https://epri-peac.com/solar-equipment/modules/sunevo-solar-co-ltd/sunevo-solar-co-ltd-se5-72h-560mb/) | 560.0 | 526.8 | 50.0 | 21.71 | 5 |
| [**SunEvo Solar Co Ltd SE5-72H-540MB**](https://epri-peac.com/solar-equipment/modules/sunevo-solar-co-ltd/sunevo-solar-co-ltd-se5-72h-540mb/) | 540.0 | 507.6 | 49.6 | 20.93 | 4 |
| [**SunEvo Solar Co Ltd SE5-72H-520MB**](https://epri-peac.com/solar-equipment/modules/sunevo-solar-co-ltd/sunevo-solar-co-ltd-se5-72h-520mb/) | 520.0 | 488.3 | 49.2 | 20.16 | 1 |
| [**SunEvo Solar Co Ltd SE4-72H-460MB**](https://epri-peac.com/solar-equipment/modules/sunevo-solar-co-ltd/sunevo-solar-co-ltd-se4-72h-460mb/) | 460.0 | 428.2 | 50.4 | 21.2 | 5 |
| [**SunEvo Solar Co Ltd SE4-72H-440MB**](https://epri-peac.com/solar-equipment/modules/sunevo-solar-co-ltd/sunevo-solar-co-ltd-se4-72h-440mb/) | 440.0 | 409.1 | 49.6 | 20.28 | 3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SunEvo Solar Co Ltd Solar Hardware?

Evaluate SunEvo Solar Co Ltd CEC certifications (440–560W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- SunEvo Solar Co Ltd certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### SunEvo Solar Co Ltd Module + Third-Party Inverter

Pair SunEvo Solar Co Ltd modules (440–560W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to SunEvo Solar Co Ltd photovoltaic and inverter hardware listed on the CEC registry.

### How many SunEvo Solar Co Ltd solar models are verified on the CEC list?

Our CEC archive indexes 5 SunEvo Solar Co Ltd equipment records (5 module series and 0 inverter models) spanning 440–560W PV. Check local building department permit requirements for Sunevo Solar Co Ltd before finalizing component orders.

### What should homeowners check before approving SunEvo Solar Co Ltd equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are SunEvo Solar Co Ltd solar panels compared to CEC averages?

Across listed series, SunEvo Solar Co Ltd modules show a median aperture efficiency of 20.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Sunevo Solar Co Ltd.

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to SunEvo Solar Co Ltd.

[Suzhou Akcome Optronics Science & Technology Co Ltd CEC Solar Catalog (390–555W PV)](https://epri-peac.com/solar-equipment/brands/suzhou-akcome-optronics-science-technology-co-ltd/) [T-Solar Global CEC Solar Catalog (97–410W PV)](https://epri-peac.com/solar-equipment/brands/t-solar-global/) [Solarhome Tech Inc CEC Solar Catalog (270–380W PV)](https://epri-peac.com/solar-equipment/brands/solarhome-tech-inc/) [United Energy Co Ltd CEC Solar Catalog (440–560W PV)](https://epri-peac.com/solar-equipment/brands/united-energy-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
