# Star Charge Americas Corp — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Star Charge Americas Corp holds 10 verified California Energy Commission (CEC) certifications and 10 grid-support inverter models (3,315–134,288W AC). On the AC conversion side, Star Charge Americas Corp lists 10 CEC-certified inverters from 3,315 W to 134,288 W AC (97.3% median weighted CEC efficiency, including 6 battery-ready hybrid units).

- **Manufacturer** : Star Charge Americas Corp

- **PV Module Series** : 0

- **Listed Inverters** : 10

- **Output Range** : 3,315–134,288W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Star Charge Americas Corp Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for Star Charge Americas Corp.

Star Charge Americas Corp participates in the California Energy Commission (CEC) Solar Equipment List with 10 total certified hardware listings. On the AC conversion side, Star Charge Americas Corp lists 10 CEC-certified inverters from 3,315 W to 134,288 W AC (97.3% median weighted CEC efficiency, including 6 battery-ready hybrid units). No active CPSC electrical recalls match Star Charge Americas Corp in our federal recall archive as of 2026.

## Which Star Charge Americas Corp Grid-Support Inverters Are Listed? (10)

Review every Star Charge Americas Corp grid-support and hybrid inverter model below to confirm NEC 705.12 backfeed breaker sizing and string voltage headroom.

Filter Star Charge Americas Corp Inverters

Verified CEC grid-support inverters from Star Charge Americas Corp.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Star Charge Americas Corp: SI135TULT10 {480V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si135tult10-480v/) | 134,288 | 480.0 | 1050.0 | 98.34 |
| [**Star Charge Americas Corp: SI135TULT00 {480V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si135tult00-480v/) | 133,148 | 480.0 | 1050.0 | 98.07 |
| [**Star Charge Americas Corp: SI125TULT00 {480V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si125tult00-480v/) | 124,382 | 480.0 | 1000.0 | 98.49 |
| [**Star Charge Americas Corp: SI125TULT10 {480V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si125tult10-480v/) | 124,346 | 480.0 | 1050.0 | 98.51 |
| [**Star Charge Americas Corp: SI104LULA00 {240V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si104lula00-240v/) | 9,582 | 240.0 | 480.0 | 96.61 |
| [**Star Charge Americas Corp: SI104LULA00 {208V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si104lula00-208v/) | 8,304 | 208.0 | 480.0 | 96.49 |
| [**Star Charge Americas Corp: SI803LULA00 {240V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si803lula00-240v/) | 7,641 | 240.0 | 480.0 | 96.8 |
| [**Star Charge Americas Corp: SI803LULA00 {208V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si803lula00-208v/) | 6,635 | 208.0 | 480.0 | 96.82 |
| [**Star Charge Americas Corp: SI403LULA00 {240V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si403lula00-240v/) | 3,811 | 240.0 | 480.0 | 97.07 |
| [**Star Charge Americas Corp: SI403LULA00 {208V}**](https://epri-peac.com/solar-equipment/inverters/star-charge-americas-corp/star-charge-americas-corp-si403lula00-208v/) | 3,315 | 208.0 | 480.0 | 97.45 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Star Charge Americas Corp Solar Hardware?

Evaluate Star Charge Americas Corp CEC certifications (3,315–134,288W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Star Charge Americas Corp supplies 10 inverter models on the CEC list; cold-climate roofs must check string Voc rise against the inverter's Vdcmax limit before finalizing module count.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Star Charge Americas Corp AC Conversion (3,315–134,288W AC)

Match Star Charge Americas Corp MPPT channels and Vdcmax ceilings to third-party CEC panels, verifying NEC 705.12 120% panel busbar limits.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Star Charge Americas Corp solar equipment.

### How many Star Charge Americas Corp solar models are verified on the CEC list?

Our CEC archive indexes 10 Star Charge Americas Corp equipment records (0 module series and 10 inverter models) spanning 3,315–134,288W AC. Check local building department permit requirements for Star Charge Americas Corp before finalizing component orders.

### What should homeowners check before approving Star Charge Americas Corp equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

## Related Pages

Compare Star Charge Americas Corp against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[Xiamen Kehua Digital Energy Tech Co Ltd CEC Solar Catalog (7,581–175,017W AC)](https://epri-peac.com/solar-equipment/brands/xiamen-kehua-digital-energy-tech-co-ltd/) [Base Power Inc CEC Solar Catalog (3,095–11,520W AC)](https://epri-peac.com/solar-equipment/brands/base-power-inc/) [SOLAREVER TECNOLOG A DE AMERICA SA DE CV CEC Solar Catalog (365–555W PV)](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) [DONGGUAN SUNWORTH SOLAR ENERGY CO LTD CEC Solar Catalog (390–550W PV)](https://epri-peac.com/solar-equipment/brands/dongguan-sunworth-solar-energy-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)