title: "SOLAR LONG PV-TECH(CAMBODIA)COLTD Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/
description: "CEC datasheets for SOLAR LONG PV-TECH(CAMBODIA)COLTD: 395–555W PV, 4 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# SOLAR LONG PV-TECH(CAMBODIA)COLTD — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

SOLAR LONG PV-TECH(CAMBODIA)COLTD holds 4 verified California Energy Commission (CEC) certifications including 4 module series (395–555W PV). SOLAR LONG PV-TECH(CAMBODIA)COLTD carries 4 module series ranging from 395 W to 555 W STC (median 475 W vs 385 W CEC fleet median; 21.4% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : SOLAR LONG PV-TECH(CAMBODIA)COLTD

- **PV Module Series** : 4

- **Listed Inverters** : 0

- **Output Range** : 395–555W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do SOLAR LONG PV-TECH(CAMBODIA)COLTD Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how SOLAR LONG PV-TECH(CAMBODIA)COLTD photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating SOLAR LONG PV-TECH(CAMBODIA)COLTD hardware for residential interconnection can verify exact DC and AC test data across 4 CEC records. SOLAR LONG PV-TECH(CAMBODIA)COLTD carries 4 module series ranging from 395 W to 555 W STC (median 475 W vs 385 W CEC fleet median; 21.4% median aperture efficiency, cell architecture Mono-c-Si). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match SOLAR LONG PV-TECH(CAMBODIA)COLTD in our federal recall archive as of 2026.

## Which SOLAR LONG PV-TECH(CAMBODIA)COLTD PV Module Series Are CEC Certified? (4)

Every deduplicated SOLAR LONG PV-TECH(CAMBODIA)COLTD solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter SOLAR LONG PV-TECH(CAMBODIA)COLTD Modules

Deduplicated CEC photovoltaic module series for SOLAR LONG PV-TECH(CAMBODIA)COLTD.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL**](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl555mlbt-72h-vtl/) | 555.0 | 517.4 | 50.62 | 22.2 | 2 |
| [**SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL**](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl540mlbt-72h-vtl/) | 540.0 | 503.0 | 49.72 | 21.6 | 3 |
| [**SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL**](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl410ml-54h-vtl/) | 410.0 | 383.4 | 37.14 | 21.13 | 4 |
| [**SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL**](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl395ml-54h-vtl/) | 395.0 | 369.0 | 36.9 | 20.36 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD Solar Hardware?

Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD CEC certifications (395–555W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- SOLAR LONG PV-TECH(CAMBODIA)COLTD certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### SOLAR LONG PV-TECH(CAMBODIA)COLTD Module + Third-Party Inverter

Pair SOLAR LONG PV-TECH(CAMBODIA)COLTD modules (395–555W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving SOLAR LONG PV-TECH(CAMBODIA)COLTD solar equipment.

### How many SOLAR LONG PV-TECH(CAMBODIA)COLTD solar models are verified on the CEC list?

Our CEC archive indexes 4 SOLAR LONG PV-TECH(CAMBODIA)COLTD equipment records (4 module series and 0 inverter models) spanning 395–555W PV. Check local building department permit requirements for Solar Long Pv Tech Cambodia Coltd before finalizing component orders.

### What should homeowners check before approving SOLAR LONG PV-TECH(CAMBODIA)COLTD equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are SOLAR LONG PV-TECH(CAMBODIA)COLTD solar panels compared to CEC averages?

Across listed series, SOLAR LONG PV-TECH(CAMBODIA)COLTD modules show a median aperture efficiency of 21.4% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solar Long Pv Tech Cambodia Coltd.

## Related Pages

Compare SOLAR LONG PV-TECH(CAMBODIA)COLTD against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[Solarmax CEC Solar Catalog (240–305W PV)](https://epri-peac.com/solar-equipment/brands/solarmax/) [Solvari Inc CEC Solar Catalog (303–398W AC)](https://epri-peac.com/solar-equipment/brands/solvari-inc/) [SINENG ELECTRIC CO LTD CEC Solar Catalog (220,432–2,003,820W AC)](https://epri-peac.com/solar-equipment/brands/sineng-electric-co-ltd/) [Sunman (Zhenjiang) Co Ltd CEC Solar Catalog (510–530W PV)](https://epri-peac.com/solar-equipment/brands/sunman-zhenjiang-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)