---
title: "Schneider Electric USA Inc Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/schneider-electric-usa-inc/
description: "CEC datasheets for Schneider Electric USA Inc: 5,747–2,200,000W AC, 0 module series, 11 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Schneider Electric USA Inc — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Schneider Electric USA Inc holds 11 verified California Energy Commission (CEC) certifications and 11 grid-support inverter models (5,747–2,200,000W AC). On the AC conversion side, Schneider Electric USA Inc lists 11 CEC-certified inverters from 5,747 W to 2,200,000 W AC (97.4% median weighted CEC efficiency, including 1 battery-ready hybrid units).

- **Manufacturer** : Schneider Electric USA Inc

- **PV Module Series** : 0

- **Listed Inverters** : 11

- **Output Range** : 5,747–2,200,000W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Schneider Electric USA Inc Solar Specifications Compare Across the CEC Catalog?

How Schneider Electric USA Inc residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Schneider Electric USA Inc for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). On the AC conversion side, Schneider Electric USA Inc lists 11 CEC-certified inverters from 5,747 W to 2,200,000 W AC (97.4% median weighted CEC efficiency, including 1 battery-ready hybrid units). CPSC cross-check flags 6 historical electrical recall entry matching Schneider Electric USA Inc; verify serial-number clearance before purchasing older used inventory.

## Which Schneider Electric USA Inc Grid-Support Inverters Are Listed? (11)

Review every Schneider Electric USA Inc grid-support and hybrid inverter model below to confirm NEC 705.12 backfeed breaker sizing and string voltage headroom.

Filter Schneider Electric USA Inc Inverters

Verified CEC grid-support inverters from Schneider Electric USA Inc.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Schneider Electric USA Inc: CS2200-NA {600V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2200-na-600v/) | 2,200,000 | 600.0 | 1200.0 | 97.18 |
| [**Schneider Electric USA Inc: CS2000-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs2000-na-575v/) | 2,000,000 | 575.0 | 1195.0 | 97.14 |
| [**Schneider Electric USA Inc: CS1800-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1800-na-575v/) | 1,800,000 | 575.0 | 1200.0 | 97.43 |
| [**Schneider Electric USA Inc: CS1666-1-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-1-na-575v/) | 1,666,000 | 575.0 | 1200.0 | 97.54 |
| [**Schneider Electric USA Inc: CS1666-2-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-2-na-575v/) | 1,666,000 | 575.0 | 1200.0 | 97.54 |
| [**Schneider Electric USA Inc: CS1666-3-NA {575V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-cs1666-3-na-575v/) | 1,666,000 | 575.0 | 1200.0 | 97.54 |
| [**Schneider Electric USA Inc: EMGPCS0500ACCANS00 {400V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-emgpcs0500accans00-400v/) | 502,611 | 400.0 | 900.0 | 97.42 |
| [**Schneider Electric USA Inc: Conext CL125 {600V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-conext-cl125-600v/) | 125,000 | 600.0 | 1200.0 | 98.1 |
| [**Schneider Electric USA Inc: HY8K1NA1 {240V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-hy8k1na1-240v/) | 7,626 | 240.0 | 480.0 | 97.16 |
| [**Schneider Electric USA Inc: XW Pro 6848 NA {240V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-xw-pro-6848-na-240v/) | 6,019 | 240.0 | 58.0 | 92.2 |
| [**Schneider Electric USA Inc: XW Pro 6848 NA {120V}**](https://epri-peac.com/solar-equipment/inverters/schneider-electric-usa-inc/schneider-electric-usa-inc-xw-pro-6848-na-120v/) | 5,747 | 120.0 | 58.0 | 91.96 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Schneider Electric USA Inc Solar Hardware?

Evaluate Schneider Electric USA Inc CEC certifications (5,747–2,200,000W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Schneider Electric USA Inc supplies 11 inverter models on the CEC list; cold-climate roofs must check string Voc rise against the inverter's Vdcmax limit before finalizing module count.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Schneider Electric USA Inc AC Conversion (5,747–2,200,000W AC)

Match Schneider Electric USA Inc MPPT channels and Vdcmax ceilings to third-party CEC panels, verifying NEC 705.12 120% panel busbar limits.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Schneider Electric USA Inc solar equipment.

### How many Schneider Electric USA Inc solar models are verified on the CEC list?

Our CEC archive indexes 11 Schneider Electric USA Inc equipment records (0 module series and 11 inverter models) spanning 5,747–2,200,000W AC. Check local building department permit requirements for Schneider Electric Usa Inc before finalizing component orders.

### What should homeowners check before approving Schneider Electric USA Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

## Related Pages

Compare Schneider Electric USA Inc against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[Shenzhen Sinexcel Electric Co Ltd CEC Solar Catalog (29,907–1,710,710W AC)](https://epri-peac.com/solar-equipment/brands/shenzhen-sinexcel-electric-co-ltd/) [Sunny International Power CEC Solar Catalog (190–290W PV)](https://epri-peac.com/solar-equipment/brands/sunny-international-power/) [PT NUSA SOLAR INDONESIA CEC Solar Catalog (415–635W PV)](https://epri-peac.com/solar-equipment/brands/pt-nusa-solar-indonesia/) [Sunpal Power Co Ltd CEC Solar Catalog (395–685W PV)](https://epri-peac.com/solar-equipment/brands/sunpal-power-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
