title: "Renesola America Solar Panels & Inverters (23 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/renesola-america/
description: "CEC datasheets for Renesola America: 250–330W PV, 23 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Renesola America — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Renesola America holds 23 verified California Energy Commission (CEC) certifications including 23 module series (250–330W PV). Renesola America carries 23 module series ranging from 250 W to 330 W STC (median 295 W vs 385 W CEC fleet median; 16.2% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Renesola America

- **PV Module Series** : 23

- **Listed Inverters** : 0

- **Output Range** : 250–330W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Renesola America Solar Specifications Compare Across the CEC Catalog?

Technical overview of Renesola America solar certifications used by municipal inspectors and utilities to approve residential rooftop permits.

Independent third-party test metrics from the CEC confirm electrical ratings for Renesola America hardware under UL 1703/61730 and IEEE 1547 utility protocols. Typical PVUSA (PTC) real-world thermal output retains 90.8% of nameplate STC watts. Renesola America carries 23 module series ranging from 250 W to 330 W STC (median 295 W vs 385 W CEC fleet median; 16.2% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). No active CPSC electrical recalls match Renesola America in our federal recall archive as of 2026.

## Which Renesola America PV Module Series Are CEC Certified? (23)

Certified Renesola America PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Filter Renesola America Modules

Deduplicated CEC photovoltaic module series for Renesola America.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Renesola America JC330M-24/Abs**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-abs/) | 330.0 | 299.5 | 46.4 | 17.01 | 3 |
| [**Renesola America JC330M-24/Abs-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-abs-b/) | 330.0 | 299.5 | 46.4 | 17.01 | 3 |
| [**Renesola America JC330M-24/Azs**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-azs/) | 330.0 | 299.5 | 46.4 | 17.01 | 3 |
| [**Renesola America JC330M-24/Azs-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-azs-b/) | 330.0 | 299.5 | 46.4 | 17.01 | 3 |
| [**Renesola America JC315M-24/Abs**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315m-24-abs/) | 315.0 | 285.5 | 45.4 | 16.23 | 3 |
| [**Renesola America JC315M-24/Abs-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315m-24-abs-b/) | 315.0 | 285.5 | 45.4 | 16.23 | 3 |
| [**Renesola America JC315M-24/Azs**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315m-24-azs/) | 315.0 | 285.5 | 45.4 | 16.23 | 3 |
| [**Renesola America JC315M-24/Azs-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315m-24-azs-b/) | 315.0 | 285.5 | 45.4 | 16.23 | 3 |
| [**Renesola America JC315S-24/Abh**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315s-24-abh/) | 315.0 | 288.9 | 46.0 | 16.23 | 4 |
| [**Renesola America JC310S-24/Abh-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc310s-24-abh-b/) | 310.0 | 284.2 | 45.8 | 15.98 | 5 |
| [**Renesola America JC295M-24/Abh**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc295m-24-abh/) | 295.0 | 270.0 | 44.7 | 15.2 | 1 |
| [**Renesola America JC295M-24/Abh-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc295m-24-abh-b/) | 295.0 | 270.0 | 44.7 | 15.2 | 1 |
| [**Renesola America JC295S-24/Abh**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc295s-24-abh/) | 295.0 | 270.1 | 45.3 | 15.2 | 2 |
| [**Renesola America JC295S-24/Abh-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc295s-24-abh-b/) | 295.0 | 270.1 | 45.3 | 15.2 | 1 |
| [**Renesola America JC290F-24/Abh-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc290f-24-abh-b/) | 290.0 | 265.5 | 45.2 | 14.95 | 1 |
| [**Renesola America JC265M-24/Bbs**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc265m-24-bbs/) | 265.0 | 240.2 | 37.7 | 16.29 | 3 |
| [**Renesola America JC265M-24/Bbs-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc265m-24-bbs-b/) | 265.0 | 240.2 | 37.7 | 16.29 | 3 |
| [**Renesola America JC265M-24/Bzs**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc265m-24-bzs/) | 265.0 | 240.2 | 37.7 | 16.29 | 3 |
| [**Renesola America JC265M-24/Bzs-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc265m-24-bzs-b/) | 265.0 | 240.2 | 37.7 | 16.29 | 3 |
| [**Renesola America JC255S-24/Bbh**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc255s-24-bbh/) | 255.0 | 233.7 | 37.6 | 15.67 | 1 |
| [**Renesola America JC255S-24/Bbh-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc255s-24-bbh-b/) | 255.0 | 233.7 | 37.6 | 15.67 | 1 |
| [**Renesola America JC250S-24/Bbh**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc250s-24-bbh/) | 250.0 | 229.0 | 37.5 | 15.37 | 1 |
| [**Renesola America JC250S-24/Bbh-b**](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc250s-24-bbh-b/) | 250.0 | 229.0 | 37.5 | 15.37 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Renesola America Solar Hardware?

Evaluate Renesola America CEC certifications (250–330W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Renesola America certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Renesola America's median module aperture efficiency (16.2%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Renesola America Module + Third-Party Inverter

Pair Renesola America modules (250–330W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Renesola America photovoltaic and inverter hardware listed on the CEC registry. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

### How many Renesola America solar models are verified on the CEC list?

Our CEC archive indexes 23 Renesola America equipment records (23 module series and 0 inverter models) spanning 250–330W PV. Check local building department permit requirements for Renesola America before finalizing component orders.

### What should homeowners check before approving Renesola America equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Renesola America solar panels compared to CEC averages?

Across listed series, Renesola America modules show a median aperture efficiency of 16.2% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Renesola America.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Tesla Inc CEC Solar Catalog (23–430W PV / 3,336–11,508W AC)](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [US Solar CEC Solar Catalog (140–330W PV)](https://epri-peac.com/solar-equipment/brands/us-solar/) [Regitec Solar BV CEC Solar Catalog (410–580W PV)](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) [Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd CEC Solar Catalog (245–450W PV)](https://epri-peac.com/solar-equipment/brands/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)