---
title: "RECOM and Co Ltd Solar Panels and Inverters (6 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/recom-co-ltd/
description: "CEC datasheets for RECOM & Co Ltd: 395–560W PV, 6 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# RECOM & Co Ltd — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

RECOM & Co Ltd holds 6 verified California Energy Commission (CEC) certifications including 6 module series (395–560W PV). RECOM & Co Ltd carries 6 module series ranging from 395 W to 560 W STC (median 468 W vs 385 W CEC fleet median; 21.6% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : RECOM & Co Ltd

- **PV Module Series** : 6

- **Listed Inverters** : 0

- **Output Range** : 395–560W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do RECOM & Co Ltd Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for RECOM & Co Ltd.

RECOM & Co Ltd participates in the California Energy Commission (CEC) Solar Equipment List with 6 total certified hardware listings. RECOM & Co Ltd carries 6 module series ranging from 395 W to 560 W STC (median 468 W vs 385 W CEC fleet median; 21.6% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match RECOM & Co Ltd in our federal recall archive as of 2026.

## Which RECOM & Co Ltd PV Module Series Are CEC Certified? (6)

Every deduplicated RECOM & Co Ltd solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter RECOM & Co Ltd Modules

Deduplicated CEC photovoltaic module series for RECOM & Co Ltd.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**RECOM & Co Ltd RCM-560-7BMF**](https://epri-peac.com/solar-equipment/modules/recom-co-ltd/recom-co-ltd-rcm-560-7bmf/) | 560.0 | 519.2 | 50.98 | 21.88 | 3 |
| [**RECOM & Co Ltd RCM-540-7BMF**](https://epri-peac.com/solar-equipment/modules/recom-co-ltd/recom-co-ltd-rcm-540-7bmf/) | 540.0 | 500.1 | 49.8 | 21.09 | 4 |
| [**RECOM & Co Ltd RCM-500-7BMM**](https://epri-peac.com/solar-equipment/modules/recom-co-ltd/recom-co-ltd-rcm-500-7bmm/) | 500.0 | 465.4 | 45.7 | 23.04 | 3 |
| [**RECOM & Co Ltd RCM-435-7BNG**](https://epri-peac.com/solar-equipment/modules/recom-co-ltd/recom-co-ltd-rcm-435-7bng/) | 435.0 | 412.5 | 38.5 | 22.31 | 4 |
| [**RECOM & Co Ltd RCM-410-7BMG**](https://epri-peac.com/solar-equipment/modules/recom-co-ltd/recom-co-ltd-rcm-410-7bmg/) | 410.0 | 386.1 | 37.68 | 21.24 | 4 |
| [**RECOM & Co Ltd RCM-395-7BMG**](https://epri-peac.com/solar-equipment/modules/recom-co-ltd/recom-co-ltd-rcm-395-7bmg/) | 395.0 | 371.7 | 36.78 | 20.47 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for RECOM & Co Ltd Solar Hardware?

Evaluate RECOM & Co Ltd CEC certifications (395–560W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- RECOM & Co Ltd certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### RECOM & Co Ltd Module + Third-Party Inverter

Pair RECOM & Co Ltd modules (395–560W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to RECOM & Co Ltd photovoltaic and inverter hardware listed on the CEC registry.

### How many RECOM & Co Ltd solar models are verified on the CEC list?

Our CEC archive indexes 6 RECOM & Co Ltd equipment records (6 module series and 0 inverter models) spanning 395–560W PV. Check local building department permit requirements for Recom Co Ltd before finalizing component orders.

### What should homeowners check before approving RECOM & Co Ltd equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are RECOM & Co Ltd solar panels compared to CEC averages?

Across listed series, RECOM & Co Ltd modules show a median aperture efficiency of 21.6% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Recom Co Ltd.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Resun Solar Inc CEC Solar Catalog (420–580W PV)](https://epri-peac.com/solar-equipment/brands/resun-solar-inc/) [Shanghai Aerospace Automobile Electromechanical CEC Solar Catalog (240–325W PV)](https://epri-peac.com/solar-equipment/brands/shanghai-aerospace-automobile-electromechanical/) [RCT Power Energy Technology Corporation CEC Solar Catalog (7,015–14,947W AC)](https://epri-peac.com/solar-equipment/brands/rct-power-energy-technology-corporation/) [Solar Frontier KK CEC Solar Catalog (140–185W PV)](https://epri-peac.com/solar-equipment/brands/solar-frontier-kk/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
