title: "PT LESSO NEW ENERGY Solar Panels and Inverters (7 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/pt-lesso-new-energy/
description: "CEC datasheets for PT LESSO NEW ENERGY: 410–580W PV, 7 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# PT LESSO NEW ENERGY — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

PT LESSO NEW ENERGY holds 7 verified California Energy Commission (CEC) certifications including 7 module series (410–580W PV). PT LESSO NEW ENERGY carries 7 module series ranging from 410 W to 580 W STC (median 480 W vs 385 W CEC fleet median; 22.2% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : PT LESSO NEW ENERGY

- **PV Module Series** : 7

- **Listed Inverters** : 0

- **Output Range** : 410–580W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do PT LESSO NEW ENERGY Solar Specifications Compare Across the CEC Catalog?

Portfolio capacity, conversion efficiency, and safety recall screening for PT LESSO NEW ENERGY solar hardware certified under California Energy Commission standards.

Flagship CEC certification records for PT LESSO NEW ENERGY include PT LESSO NEW ENERGY 580C(HBD)72(182) alongside 7 verified brand entries. PT LESSO NEW ENERGY carries 7 module series ranging from 410 W to 580 W STC (median 480 W vs 385 W CEC fleet median; 22.2% median aperture efficiency, cell architecture Mono-c-Si). Permitting inspectors cross-reference exact CEC model strings on utility interconnection packets. No active CPSC electrical recalls match PT LESSO NEW ENERGY in our federal recall archive as of 2026.

## Which PT LESSO NEW ENERGY PV Module Series Are CEC Certified? (7)

Filter certified PT LESSO NEW ENERGY solar panels by series name, nameplate STC capacity, PTC output, open-circuit voltage, or conversion efficiency.

Filter PT LESSO NEW ENERGY Modules

Deduplicated CEC photovoltaic module series for PT LESSO NEW ENERGY.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**PT LESSO NEW ENERGY 580C(HBD)72(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-580c-hbd-72-182/) | 580.0 | 546.6 | 52.42 | 22.48 | 1 |
| [**PT LESSO NEW ENERGY 580C(HWB)72(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-580c-hwb-72-182/) | 580.0 | 548.4 | 52.42 | 22.48 | 1 |
| [**PT LESSO NEW ENERGY 550D(HBD)72(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-550d-hbd-72-182/) | 550.0 | 516.0 | 49.78 | 21.32 | 1 |
| [**PT LESSO NEW ENERGY 480C(HWB)60(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-480c-hwb-60-182/) | 480.0 | 454.0 | 43.52 | 22.22 | 1 |
| [**PT LESSO NEW ENERGY 435C(HWB)54(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-435c-hwb-54-182/) | 435.0 | 412.2 | 39.17 | 22.19 | 1 |
| [**PT LESSO NEW ENERGY 430C(HBB)54(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-430c-hbb-54-182/) | 430.0 | 406.2 | 40.13 | 22.05 | 1 |
| [**PT LESSO NEW ENERGY 410D(BPM)54(182)**](https://epri-peac.com/solar-equipment/modules/pt-lesso-new-energy/pt-lesso-new-energy-410d-bpm-54-182/) | 410.0 | 384.4 | 37.3 | 20.92 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT LESSO NEW ENERGY Solar Hardware?

Evaluate PT LESSO NEW ENERGY CEC certifications (410–580W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- PT LESSO NEW ENERGY certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### PT LESSO NEW ENERGY Module + Third-Party Inverter

Pair PT LESSO NEW ENERGY modules (410–580W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring PT LESSO NEW ENERGY solar modules or inverters. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

### How many PT LESSO NEW ENERGY solar models are verified on the CEC list?

Our CEC archive indexes 7 PT LESSO NEW ENERGY equipment records (7 module series and 0 inverter models) spanning 410–580W PV. Check local building department permit requirements for Pt Lesso New Energy before finalizing component orders.

### What should homeowners check before approving PT LESSO NEW ENERGY equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are PT LESSO NEW ENERGY solar panels compared to CEC averages?

Across listed series, PT LESSO NEW ENERGY modules show a median aperture efficiency of 22.2% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Pt Lesso New Energy.

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to PT LESSO NEW ENERGY.

[Solarbest Energy-Tech (Zhejiang) CEC Solar Catalog (180–240W PV)](https://epri-peac.com/solar-equipment/brands/solarbest-energy-tech-zhejiang/) [Sunflare Co CEC Solar Catalog (55–185W PV)](https://epri-peac.com/solar-equipment/brands/sunflare-co/) [Miasole CEC Solar Catalog (115–500W PV)](https://epri-peac.com/solar-equipment/brands/miasole/) [Sungen Power LLC CEC Solar Catalog (390–550W PV)](https://epri-peac.com/solar-equipment/brands/sungen-power-llc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)