title: "PT JAYA ELECTRICAL ENERGY Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/pt-jaya-electrical-energy/
description: "CEC datasheets for PT JAYA ELECTRICAL ENERGY: 420–585W PV, 4 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# PT JAYA ELECTRICAL ENERGY — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

PT JAYA ELECTRICAL ENERGY holds 4 verified California Energy Commission (CEC) certifications including 4 module series (420–585W PV). PT JAYA ELECTRICAL ENERGY carries 4 module series ranging from 420 W to 585 W STC (median 502 W vs 385 W CEC fleet median; 22.2% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : PT JAYA ELECTRICAL ENERGY

- **PV Module Series** : 4

- **Listed Inverters** : 0

- **Output Range** : 420–585W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do PT JAYA ELECTRICAL ENERGY Solar Specifications Compare Across the CEC Catalog?

Technical overview of PT JAYA ELECTRICAL ENERGY solar certifications used by municipal inspectors and utilities to approve residential rooftop permits.

Independent third-party test metrics from the CEC confirm electrical ratings for PT JAYA ELECTRICAL ENERGY hardware under UL 1703/61730 and IEEE 1547 utility protocols. Typical PVUSA (PTC) real-world thermal output retains 95.1% of nameplate STC watts. PT JAYA ELECTRICAL ENERGY carries 4 module series ranging from 420 W to 585 W STC (median 502 W vs 385 W CEC fleet median; 22.2% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match PT JAYA ELECTRICAL ENERGY in our federal recall archive as of 2026.

## Which PT JAYA ELECTRICAL ENERGY PV Module Series Are CEC Certified? (4)

Certified PT JAYA ELECTRICAL ENERGY PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Filter PT JAYA ELECTRICAL ENERGY Modules

Deduplicated CEC photovoltaic module series for PT JAYA ELECTRICAL ENERGY.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**PT JAYA ELECTRICAL ENERGY JAYAEGN585-144**](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn585-144/) | 585.0 | 557.4 | 51.62 | 22.67 | 5 |
| [**PT JAYA ELECTRICAL ENERGY JAYAEGN570-144**](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn570-144/) | 570.0 | 542.9 | 51.16 | 22.09 | 1 |
| [**PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)**](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn435-108-b/) | 435.0 | 412.8 | 40.1 | 22.31 | 4 |
| [**PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)**](https://epri-peac.com/solar-equipment/modules/pt-jaya-electrical-energy/pt-jaya-electrical-energy-jayaegn420-108-b/) | 420.0 | 398.3 | 39.66 | 21.54 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT JAYA ELECTRICAL ENERGY Solar Hardware?

Evaluate PT JAYA ELECTRICAL ENERGY CEC certifications (420–585W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- PT JAYA ELECTRICAL ENERGY certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### PT JAYA ELECTRICAL ENERGY Module + Third-Party Inverter

Pair PT JAYA ELECTRICAL ENERGY modules (420–585W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving PT JAYA ELECTRICAL ENERGY solar equipment.

### How many PT JAYA ELECTRICAL ENERGY solar models are verified on the CEC list?

Our CEC archive indexes 4 PT JAYA ELECTRICAL ENERGY equipment records (4 module series and 0 inverter models) spanning 420–585W PV. Check local building department permit requirements for Pt Jaya Electrical Energy before finalizing component orders.

### What should homeowners check before approving PT JAYA ELECTRICAL ENERGY equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are PT JAYA ELECTRICAL ENERGY solar panels compared to CEC averages?

Across listed series, PT JAYA ELECTRICAL ENERGY modules show a median aperture efficiency of 22.2% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Pt Jaya Electrical Energy.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[PT SURYA PERTAMA INDONESIA CEC Solar Catalog (560–585W PV)](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/) [Saatvik Green Energy (P) Limited CEC Solar Catalog (395–540W PV)](https://epri-peac.com/solar-equipment/brands/saatvik-green-energy-p-limited/) [Princeton Power Systems Inc CEC Solar Catalog (29,444–124,964W AC)](https://epri-peac.com/solar-equipment/brands/princeton-power-systems-inc/) [Savant Systems Inc CEC Solar Catalog (9,922–12,410W AC)](https://epri-peac.com/solar-equipment/brands/savant-systems-inc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)