# Power Center — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Power Center holds 17 verified California Energy Commission (CEC) certifications and 17 grid-support inverter models (303–60,050W AC). On the AC conversion side, Power Center lists 17 CEC-certified inverters from 303 W to 60,050 W AC (96.3% median weighted CEC efficiency, including 6 battery-ready hybrid units). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Power Center

- **PV Module Series** : 0

- **Listed Inverters** : 17

- **Output Range** : 303–60,050W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Power Center Solar Specifications Compare Across the CEC Catalog?

Technical overview of Power Center solar certifications used by municipal inspectors and utilities to approve residential rooftop permits.

Independent third-party test metrics from the CEC confirm electrical ratings for Power Center hardware under UL 1703/61730 and IEEE 1547 utility protocols. On the AC conversion side, Power Center lists 17 CEC-certified inverters from 303 W to 60,050 W AC (96.3% median weighted CEC efficiency, including 6 battery-ready hybrid units). No active CPSC electrical recalls match Power Center in our federal recall archive as of 2026.

## Which Power Center Grid-Support Inverters Are Listed? (17)

Technical ratings for listed Power Center string, microinverter, and storage-ready units with links to complete NEC wiring checks.

Filter Power Center Inverters

Verified CEC grid-support inverters from Power Center.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Power Center: Max Hybrid 60 {277V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-60-277v/) | 60,050 | 277.0 | 850.0 | 96.86 |
| [**Power Center: Max Hybrid 30 (208V) {120V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-30-208v-120v/) | 30,025 | 120.0 | 500.0 | 95.56 |
| [**Power Center: Max Hybrid 15 {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-15-240v/) | 15,040 | 240.0 | 425.0 | 96.37 |
| [**Power Center: Max Hybrid 15 {208V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-max-hybrid-15-208v/) | 13,010 | 208.0 | 425.0 | 96.29 |
| [**Power Center: Essential Hybrid 5 {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-essential-hybrid-5-240v/) | 7,970 | 240.0 | 425.0 | 95.58 |
| [**Power Center: Essential Hybrid 5 {120V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-essential-hybrid-5-120v/) | 4,787 | 120.0 | 425.0 | 95.59 |
| [**Power Center: D1500-M4 {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d1500-m4-240v/) | 1,439 | 240.0 | 48.0 | 96.44 |
| [**Power Center: D800-M2A-240A {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d800-m2a-240a-240v/) | 772 | 240.0 | 55.0 | 96.29 |
| [**Power Center: D800-M2A-208A {208V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d800-m2a-208a-208v/) | 707 | 208.0 | 55.0 | 96.33 |
| [**Power Center: D700-M2 {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d700-m2-240v/) | 697 | 240.0 | 48.0 | 96.46 |
| [**Power Center: D600-M2A-208A {208V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d600-m2a-208a-208v/) | 590 | 208.0 | 55.0 | 96.28 |
| [**Power Center: D600-M2A-240A {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d600-m2a-240a-240v/) | 576 | 240.0 | 55.0 | 96.29 |
| [**Power Center: D400-M1A-240A {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d400-m1a-240a-240v/) | 398 | 240.0 | 55.0 | 96.28 |
| [**Power Center: D350-M1 {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d350-m1-240v/) | 350 | 240.0 | 48.0 | 96.4 |
| [**Power Center: D350-M1A-240A {240V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d350-m1a-240a-240v/) | 346 | 240.0 | 55.0 | 96.29 |
| [**Power Center: D400-M1A-208A {208V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d400-m1a-208a-208v/) | 343 | 208.0 | 55.0 | 96.32 |
| [**Power Center: D350-M1A-208A {208V}**](https://epri-peac.com/solar-equipment/inverters/power-center/power-center-d350-m1a-208a-208v/) | 303 | 208.0 | 55.0 | 96.3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Power Center Solar Hardware?

Evaluate Power Center CEC certifications (303–60,050W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Power Center supplies 17 inverter models on the CEC list; cold-climate roofs must check string Voc rise against the inverter's Vdcmax limit before finalizing module count.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Power Center AC Conversion (303–60,050W AC)

Match Power Center MPPT channels and Vdcmax ceilings to third-party CEC panels, verifying NEC 705.12 120% panel busbar limits.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering Power Center CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

### How many Power Center solar models are verified on the CEC list?

Our CEC archive indexes 17 Power Center equipment records (0 module series and 17 inverter models) spanning 303–60,050W AC. Check local building department permit requirements for Power Center before finalizing component orders.

### What should homeowners check before approving Power Center equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[TSEC CEC Solar Catalog (365–550W PV)](https://epri-peac.com/solar-equipment/brands/tsec/) [Wuxi Sunket New Energy Technology Co Ltd CEC Solar Catalog (415–625W PV)](https://epri-peac.com/solar-equipment/brands/wuxi-sunket-new-energy-technology-co-ltd/) [Meyer Burger (Industries) GmbH CEC Solar Catalog (370–570W PV)](https://epri-peac.com/solar-equipment/brands/meyer-burger-industries-gmbh/) [Shenzhen Lux Power Technology Co Ltd CEC Solar Catalog (7,859–25,129W AC)](https://epri-peac.com/solar-equipment/brands/shenzhen-lux-power-technology-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)