title: "PEIMAR Solar Panels & Inverters (53 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/peimar/
description: "CEC datasheets for PEIMAR: 165–550W PV, 53 module series, 0 inverter models, and NEC limits. Verified California Energy Commission solar ratings and NEC limits."
---

CEC Brand Hub

# PEIMAR — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

PEIMAR holds 53 verified California Energy Commission (CEC) certifications including 53 module series (165–550W PV). PEIMAR carries 53 module series ranging from 165 W to 550 W STC (median 360 W vs 385 W CEC fleet median; 19.9% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : PEIMAR

- **PV Module Series** : 53

- **Listed Inverters** : 0

- **Output Range** : 165–550W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do PEIMAR Solar Specifications Compare Across the CEC Catalog?

How PEIMAR residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying PEIMAR for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). PEIMAR carries 53 module series ranging from 165 W to 550 W STC (median 360 W vs 385 W CEC fleet median; 19.9% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). No active CPSC electrical recalls match PEIMAR in our federal recall archive as of 2026.

## Which PEIMAR PV Module Series Are CEC Certified? (53)

Every deduplicated PEIMAR solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter PEIMAR Modules

Deduplicated CEC photovoltaic module series for PEIMAR.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**PEIMAR DR10H550M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-dr10h550m/) | 550.0 | 515.7 | 49.6 | 21.48 | 1 |
| [**PEIMAR SE550M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se550m/) | 550.0 | 516.9 | 49.8 | 21.83 | 1 |
| [**PEIMAR DR10H540M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-dr10h540m/) | 540.0 | 506.1 | 49.4 | 21.09 | 4 |
| [**PEIMAR SE535M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se535m/) | 535.0 | 502.5 | 49.5 | 21.23 | 5 |
| [**PEIMAR SE520M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se520m/) | 520.0 | 488.0 | 49.2 | 20.63 | 1 |
| [**PEIMAR SE505M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se505m/) | 505.0 | 474.7 | 45.6 | 21.96 | 2 |
| [**PEIMAR SE485M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se485m/) | 485.0 | 455.4 | 45.2 | 21.09 | 5 |
| [**PEIMAR DR10H455M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-dr10h455m/) | 455.0 | 426.5 | 41.3 | 21.26 | 3 |
| [**PEIMAR SE455M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se455m/) | 455.0 | 427.6 | 41.3 | 21.67 | 3 |
| [**PEIMAR SL455M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sl455m/) | 455.0 | 426.9 | 50.36 | 21.06 | 3 |
| [**PEIMAR DR10H445M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-dr10h445m/) | 445.0 | 416.9 | 41.1 | 20.79 | 2 |
| [**PEIMAR SE440M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se440m/) | 440.0 | 413.1 | 41.0 | 20.95 | 4 |
| [**PEIMAR SF435M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sf435m/) | 435.0 | 406.8 | 50.5 | 20.71 | 4 |
| [**PEIMAR SL435M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sl435m/) | 435.0 | 407.6 | 49.5 | 20.14 | 5 |
| [**PEIMAR SF420M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sf420m/) | 420.0 | 392.4 | 48.96 | 20.0 | 2 |
| [**PEIMAR DR10H410M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-dr10h410m/) | 410.0 | 384.3 | 37.1 | 21.13 | 4 |
| [**PEIMAR SE410M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se410m/) | 410.0 | 385.3 | 37.2 | 21.69 | 4 |
| [**PEIMAR SF405M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sf405m/) | 405.0 | 378.9 | 45.84 | 20.98 | 2 |
| [**PEIMAR SM400M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm400m/) | 400.0 | 371.5 | 50.39 | 20.62 | 1 |
| [**PEIMAR DR10H395M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-dr10h395m/) | 395.0 | 369.9 | 36.9 | 20.36 | 1 |
| [**PEIMAR SE390M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-se390m/) | 390.0 | 366.0 | 36.8 | 20.63 | 3 |
| [**PEIMAR SF390M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sf390m/) | 390.0 | 364.5 | 45.12 | 20.21 | 4 |
| [**PEIMAR SM385M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm385m/) | 385.0 | 357.2 | 49.66 | 19.85 | 5 |
| [**PEIMAR SL380M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sl380m/) | 380.0 | 356.5 | 42.11 | 20.99 | 3 |
| [**PEIMAR SL365M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sl365m/) | 365.0 | 342.1 | 41.4 | 20.17 | 4 |
| [**PEIMAR SM365M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm365m/) | 365.0 | 338.2 | 48.68 | 18.81 | 4 |
| [**PEIMAR SF360M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sf360m/) | 360.0 | 336.6 | 41.2 | 20.57 | 4 |
| [**PEIMAR SG360M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg360m/) | 360.0 | 328.1 | 48.44 | 18.56 | 5 |
| [**PEIMAR SF345M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sf345m/) | 345.0 | 322.2 | 40.5 | 19.71 | 1 |
| [**PEIMAR SG335M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg335m/) | 335.0 | 304.6 | 46.85 | 17.26 | 5 |
| [**PEIMAR SG330P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg330p/) | 330.0 | 299.7 | 46.24 | 17.01 | 2 |
| [**PEIMAR SM330M (BF)**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm330m-bf/) | 330.0 | 305.8 | 41.91 | 20.25 | 2 |
| [**PEIMAR SM325M (FB)**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm325m-fb/) | 325.0 | 300.0 | 41.67 | 19.94 | 1 |
| [**PEIMAR SG320M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg320m/) | 320.0 | 288.2 | 44.9 | 16.49 | 1 |
| [**PEIMAR SG310M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg310m/) | 310.0 | 280.5 | 40.81 | 19.02 | 4 |
| [**PEIMAR SG310P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg310p/) | 310.0 | 281.0 | 44.65 | 15.98 | 5 |
| [**PEIMAR SM310M (BF)**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm310m-bf/) | 310.0 | 286.8 | 40.94 | 19.02 | 5 |
| [**PEIMAR SM310M (FB)**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm310m-fb/) | 310.0 | 285.8 | 40.94 | 19.02 | 5 |
| [**PEIMAR SG295P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg295p/) | 295.0 | 263.7 | 43.3 | 15.2 | 1 |
| [**PEIMAR SM295M (BF)**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm295m-bf/) | 295.0 | 272.5 | 40.21 | 18.1 | 1 |
| [**PEIMAR SM295M (FB)**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sm295m-fb/) | 295.0 | 271.6 | 40.21 | 18.1 | 1 |
| [**PEIMAR SG290M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg290m/) | 290.0 | 260.5 | 44.16 | 14.95 | 4 |
| [**PEIMAR SG285P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg285p/) | 285.0 | 255.9 | 39.02 | 17.48 | 4 |
| [**PEIMAR SG275M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg275m/) | 275.0 | 248.5 | 37.88 | 16.9 | 1 |
| [**PEIMAR SG260M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg260m/) | 260.0 | 234.5 | 37.39 | 15.98 | 5 |
| [**PEIMAR SG260P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg260p/) | 260.0 | 235.7 | 37.81 | 15.95 | 5 |
| [**PEIMAR SG235M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg235m/) | 235.0 | 211.4 | 36.65 | 14.44 | 5 |
| [**PEIMAR SG235P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg235p/) | 235.0 | 209.8 | 36.1 | 14.44 | 5 |
| [**PEIMAR SG220M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg220m/) | 220.0 | 197.6 | 36.29 | 13.52 | 1 |
| [**PEIMAR SG215P**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg215p/) | 215.0 | 191.5 | 35.4 | 13.22 | 4 |
| [**PEIMAR SG200M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg200m/) | 200.0 | 178.0 | 45.7 | 15.67 | 1 |
| [**PEIMAR SG185M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg185m/) | 185.0 | 164.2 | 43.4 | 14.49 | 5 |
| [**PEIMAR SG165M**](https://epri-peac.com/solar-equipment/modules/peimar/peimar-sg165m/) | 165.0 | 146.0 | 42.5 | 12.92 | 3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PEIMAR Solar Hardware?

Evaluate PEIMAR CEC certifications (165–550W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- PEIMAR certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: PEIMAR's median module aperture efficiency (19.9%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### PEIMAR Module + Third-Party Inverter

Pair PEIMAR modules (165–550W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering PEIMAR CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

### How many PEIMAR solar models are verified on the CEC list?

Our CEC archive indexes 53 PEIMAR equipment records (53 module series and 0 inverter models) spanning 165–550W PV. Check local building department permit requirements for Peimar before finalizing component orders.

### What should homeowners check before approving PEIMAR equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are PEIMAR solar panels compared to CEC averages?

Across listed series, PEIMAR modules show a median aperture efficiency of 19.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Peimar.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[Auxin Solar CEC Solar Catalog (140–610W PV)](https://epri-peac.com/solar-equipment/brands/auxin-solar/) [Power Electronics CEC Solar Catalog (1,163,500–4,198,715W AC)](https://epri-peac.com/solar-equipment/brands/power-electronics/) [Zhejiang Sunpro Power Technology Co Ltd CEC Solar Catalog (395–680W PV)](https://epri-peac.com/solar-equipment/brands/zhejiang-sunpro-power-technology-co-ltd/) [Solar4America Technology Inc CEC Solar Catalog (320–585W PV)](https://epri-peac.com/solar-equipment/brands/solar4america-technology-inc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)