---
title: "ONYX SOLAR ENERGY SL Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/onyx-solar-energy-sl/
description: "CEC datasheets for ONYX SOLAR ENERGY SL: 291W PV, 1 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# ONYX SOLAR ENERGY SL — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

ONYX SOLAR ENERGY SL holds 1 verified California Energy Commission (CEC) certifications including 1 module series (291W PV). ONYX SOLAR ENERGY SL carries 1 module series ranging from 291 W to 291 W STC (median 291 W vs 385 W CEC fleet median; 14.6% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : ONYX SOLAR ENERGY SL

- **PV Module Series** : 1

- **Listed Inverters** : 0

- **Output Range** : 291W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do ONYX SOLAR ENERGY SL Solar Specifications Compare Across the CEC Catalog?

How ONYX SOLAR ENERGY SL residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying ONYX SOLAR ENERGY SL for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). ONYX SOLAR ENERGY SL carries 1 module series ranging from 291 W to 291 W STC (median 291 W vs 385 W CEC fleet median; 14.6% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match ONYX SOLAR ENERGY SL in our federal recall archive as of 2026.

## Which ONYX SOLAR ENERGY SL PV Module Series Are CEC Certified? (1)

Filter certified ONYX SOLAR ENERGY SL solar panels by series name, nameplate STC capacity, PTC output, open-circuit voltage, or conversion efficiency.

Filter ONYX SOLAR ENERGY SL Modules

Deduplicated CEC photovoltaic module series for ONYX SOLAR ENERGY SL.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**ONYX SOLAR ENERGY SL ONYX G/G M06666**](https://epri-peac.com/solar-equipment/modules/onyx-solar-energy-sl/onyx-solar-energy-sl-onyx-g-g-m06666/) | 291.0 | 256.6 | 42.0 | 14.62 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for ONYX SOLAR ENERGY SL Solar Hardware?

Evaluate ONYX SOLAR ENERGY SL CEC certifications (291W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- ONYX SOLAR ENERGY SL certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: ONYX SOLAR ENERGY SL's median module aperture efficiency (14.6%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### ONYX SOLAR ENERGY SL Module + Third-Party Inverter

Pair ONYX SOLAR ENERGY SL modules (291W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to ONYX SOLAR ENERGY SL photovoltaic and inverter hardware listed on the CEC registry.

### How many ONYX SOLAR ENERGY SL solar models are verified on the CEC list?

Our CEC archive indexes 1 ONYX SOLAR ENERGY SL equipment records (1 module series and 0 inverter models) spanning 291W PV. Check local building department permit requirements for Onyx Solar Energy Sl before finalizing component orders.

### What should homeowners check before approving ONYX SOLAR ENERGY SL equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are ONYX SOLAR ENERGY SL solar panels compared to CEC averages?

Across listed series, ONYX SOLAR ENERGY SL modules show a median aperture efficiency of 14.6% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Onyx Solar Energy Sl.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Over Easy Solar CEC Solar Catalog (64W PV)](https://epri-peac.com/solar-equipment/brands/over-easy-solar/) [Perfect Source Technology CEC Solar Catalog (188W PV)](https://epri-peac.com/solar-equipment/brands/perfect-source-technology/) [ONE SUN MEXICO SA DE CV CEC Solar Catalog (9,975W AC)](https://epri-peac.com/solar-equipment/brands/one-sun-mexico-sa-de-cv/) [POMCube Inc CEC Solar Catalog (9,920W AC)](https://epri-peac.com/solar-equipment/brands/pomcube-inc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
