title: "Mitrex Solar Panels & Inverters (12 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/mitrex/
description: "CEC datasheets for Mitrex: 295–440W PV, 12 module series, 0 inverter models, and NEC limits. Verified California Energy Commission solar ratings and NEC limits."
---

CEC Brand Hub

# Mitrex — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Mitrex holds 12 verified California Energy Commission (CEC) certifications including 12 module series (295–440W PV). Mitrex carries 12 module series ranging from 295 W to 440 W STC (median 395 W vs 385 W CEC fleet median; 19.9% median aperture efficiency, cell architecture Mono-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Mitrex

- **PV Module Series** : 12

- **Listed Inverters** : 0

- **Output Range** : 295–440W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Mitrex Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for Mitrex.

Mitrex participates in the California Energy Commission (CEC) Solar Equipment List with 12 total certified hardware listings. Mitrex carries 12 module series ranging from 295 W to 440 W STC (median 395 W vs 385 W CEC fleet median; 19.9% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match Mitrex in our federal recall archive as of 2026.

## Which Mitrex PV Module Series Are CEC Certified? (12)

Every deduplicated Mitrex solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Mitrex Modules

Deduplicated CEC photovoltaic module series for Mitrex.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Mitrex M440-H1H**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m440-h1h/) | 440.0 | 409.8 | 49.53 | 20.47 | 1 |
| [**Mitrex M410-I3H**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m410-i3h/) | 410.0 | 381.7 | 37.25 | 21.03 | 4 |
| [**Mitrex M410-L3H**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m410-l3h/) | 410.0 | 386.1 | 37.68 | 21.24 | 4 |
| [**Mitrex M400-A1F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m400-a1f/) | 400.0 | 368.9 | 48.3 | 20.0 | 1 |
| [**Mitrex M400-B1F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m400-b1f/) | 400.0 | 369.0 | 48.3 | 20.0 | 1 |
| [**Mitrex M395-B1F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m395-b1f/) | 395.0 | 364.3 | 48.3 | 19.75 | 1 |
| [**Mitrex M395-L3H**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m395-l3h/) | 395.0 | 371.7 | 36.78 | 20.47 | 1 |
| [**Mitrex M390-A1F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m390-a1f/) | 390.0 | 359.4 | 48.2 | 19.5 | 1 |
| [**Mitrex M355-RF041F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m355-rf041f/) | 355.0 | 325.0 | 49.0 | 17.75 | 2 |
| [**Mitrex M335-RF041F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m335-rf041f/) | 335.0 | 305.1 | 48.8 | 16.75 | 5 |
| [**Mitrex M310-RF041F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m310-rf041f/) | 310.0 | 281.9 | 48.5 | 15.5 | 5 |
| [**Mitrex M295-RF041F**](https://epri-peac.com/solar-equipment/modules/mitrex/mitrex-m295-rf041f/) | 295.0 | 267.9 | 48.4 | 14.75 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Mitrex Solar Hardware?

Evaluate Mitrex CEC certifications (295–440W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Mitrex certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Mitrex's median module aperture efficiency (19.9%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Mitrex Module + Third-Party Inverter

Pair Mitrex modules (295–440W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Mitrex solar equipment. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

### How many Mitrex solar models are verified on the CEC list?

Our CEC archive indexes 12 Mitrex equipment records (12 module series and 0 inverter models) spanning 295–440W PV. Check local building department permit requirements for Mitrex before finalizing component orders.

### What should homeowners check before approving Mitrex equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Mitrex solar panels compared to CEC averages?

Across listed series, Mitrex modules show a median aperture efficiency of 19.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitrex.

## Related Pages

Compare Mitrex against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[Sunrise Solartech CEC Solar Catalog (220–310W PV)](https://epri-peac.com/solar-equipment/brands/sunrise-solartech/) [WINAICO CEC Solar Catalog (235–335W PV)](https://epri-peac.com/solar-equipment/brands/winaico/) [Liniotech Energy Inc CEC Solar Catalog (5,020–10,186W AC)](https://epri-peac.com/solar-equipment/brands/liniotech-energy-inc/) [AMPS Solar CEC Solar Catalog (395–600W PV)](https://epri-peac.com/solar-equipment/brands/amps-solar/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)