---
title: "MECEN SOLAR VINA COLTD Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/mecen-solar-vina-coltd/
description: "CEC datasheets for MECEN SOLAR VINA COLTD: 395–550W PV, 4 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# MECEN SOLAR VINA COLTD — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

MECEN SOLAR VINA COLTD holds 4 verified California Energy Commission (CEC) certifications including 4 module series (395–550W PV). MECEN SOLAR VINA COLTD carries 4 module series ranging from 395 W to 550 W STC (median 475 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : MECEN SOLAR VINA COLTD

- **PV Module Series** : 4

- **Listed Inverters** : 0

- **Output Range** : 395–550W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do MECEN SOLAR VINA COLTD Solar Specifications Compare Across the CEC Catalog?

Independent datasheet aggregation for MECEN SOLAR VINA COLTD across 4 certified listings, highlighting wattage coverage, PTC retention, and inverter topology.

CEC engineering compliance records for MECEN SOLAR VINA COLTD cover 4 module series and 0 inverter models. MECEN SOLAR VINA COLTD carries 4 module series ranging from 395 W to 550 W STC (median 475 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si). Across tested modules, median efficiency of 20.9% runs 1.0 percentage points above the 19.91% CEC benchmark. No active CPSC electrical recalls match MECEN SOLAR VINA COLTD in our federal recall archive as of 2026.

## Which MECEN SOLAR VINA COLTD PV Module Series Are CEC Certified? (4)

Inspect MECEN SOLAR VINA COLTD photovoltaic panel series sorted from highest STC wattage downward; near-identical wattage trims are grouped inside each series page.

Filter MECEN SOLAR VINA COLTD Modules

Deduplicated CEC photovoltaic module series for MECEN SOLAR VINA COLTD.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**MECEN SOLAR VINA COLTD MC7G72M-550**](https://epri-peac.com/solar-equipment/modules/mecen-solar-vina-coltd/mecen-solar-vina-coltd-mc7g72m-550/) | 550.0 | 508.2 | 49.92 | 21.24 | 1 |
| [**MECEN SOLAR VINA COLTD MC7G72M-540**](https://epri-peac.com/solar-equipment/modules/mecen-solar-vina-coltd/mecen-solar-vina-coltd-mc7g72m-540/) | 540.0 | 498.7 | 49.6 | 20.85 | 4 |
| [**MECEN SOLAR VINA COLTD MC7G54M(H)-410**](https://epri-peac.com/solar-equipment/modules/mecen-solar-vina-coltd/mecen-solar-vina-coltd-mc7g54m-h-410/) | 410.0 | 380.6 | 37.5 | 21.0 | 4 |
| [**MECEN SOLAR VINA COLTD MC7G54M(H)-395**](https://epri-peac.com/solar-equipment/modules/mecen-solar-vina-coltd/mecen-solar-vina-coltd-mc7g54m-h-395/) | 395.0 | 366.3 | 36.8 | 20.24 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for MECEN SOLAR VINA COLTD Solar Hardware?

Evaluate MECEN SOLAR VINA COLTD CEC certifications (395–550W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- MECEN SOLAR VINA COLTD certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### MECEN SOLAR VINA COLTD Module + Third-Party Inverter

Pair MECEN SOLAR VINA COLTD modules (395–550W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering MECEN SOLAR VINA COLTD CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

### How many MECEN SOLAR VINA COLTD solar models are verified on the CEC list?

Our CEC archive indexes 4 MECEN SOLAR VINA COLTD equipment records (4 module series and 0 inverter models) spanning 395–550W PV. Check local building department permit requirements for Mecen Solar Vina Coltd before finalizing component orders.

### What should homeowners check before approving MECEN SOLAR VINA COLTD equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are MECEN SOLAR VINA COLTD solar panels compared to CEC averages?

Across listed series, MECEN SOLAR VINA COLTD modules show a median aperture efficiency of 20.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mecen Solar Vina Coltd.

## Related Pages

Compare MECEN SOLAR VINA COLTD against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[NeoVolta Inc CEC Solar Catalog (7,447–16,199W AC)](https://epri-peac.com/solar-equipment/brands/neovolta-inc/) [NEXTRACKER LLC CEC Solar Catalog (801,420–5,004,900W AC)](https://epri-peac.com/solar-equipment/brands/nextracker-llc/) [Luxco CEC Solar Catalog (245–300W PV)](https://epri-peac.com/solar-equipment/brands/luxco/) [Nuuko Solar GmbH CEC Solar Catalog (565–710W PV)](https://epri-peac.com/solar-equipment/brands/nuuko-solar-gmbh/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
