title: "KACO new energy GmbH Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/kaco-new-energy-gmbh/
description: "CEC datasheets for KACO new energy GmbH: 109,765–151,228W AC, 0 module series, 8 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# KACO new energy GmbH — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

KACO new energy GmbH holds 8 verified California Energy Commission (CEC) certifications and 8 grid-support inverter models (109,765–151,228W AC). On the AC conversion side, KACO new energy GmbH lists 8 CEC-certified inverters from 109,765 W to 151,228 W AC (98.7% median weighted CEC efficiency, grid-tied topologies). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : KACO new energy GmbH

- **PV Module Series** : 0

- **Listed Inverters** : 8

- **Output Range** : 109,765–151,228W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do KACO new energy GmbH Solar Specifications Compare Across the CEC Catalog?

How KACO new energy GmbH residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying KACO new energy GmbH for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). On the AC conversion side, KACO new energy GmbH lists 8 CEC-certified inverters from 109,765 W to 151,228 W AC (98.7% median weighted CEC efficiency, grid-tied topologies). No active CPSC electrical recalls match KACO new energy GmbH in our federal recall archive as of 2026.

## Which KACO new energy GmbH Grid-Support Inverters Are Listed? (8)

Filter KACO new energy GmbH inverters approved for utility interconnection across 240V split-phase residential and 208V/480V commercial electrical services.

Filter KACO new energy GmbH Inverters

Verified CEC grid-support inverters from KACO new energy GmbH.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-150-tl3-m1-wm-od-iiq0-660v/) | 151,228 | 660.0 | 1300.0 | 98.78 |
| [**KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-150-tl3-m1-wm-od-iiqx-660v/) | 151,228 | 660.0 | 1300.0 | 98.78 |
| [**KACO new energy GmbH: KACO blueplanet 125 TL3 M1 WM OD IIP0 {600V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-125-tl3-m1-wm-od-iip0-600v/) | 138,663 | 600.0 | 1300.0 | 98.69 |
| [**KACO new energy GmbH: KACO blueplanet 125 TL3 M1 WM OD IIPX {600V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-125-tl3-m1-wm-od-iipx-600v/) | 138,663 | 600.0 | 1300.0 | 98.69 |
| [**KACO new energy GmbH: KACO blueplanet 137 TL3 M1 WM OD IIP0 {600V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-137-tl3-m1-wm-od-iip0-600v/) | 138,663 | 600.0 | 1300.0 | 98.69 |
| [**KACO new energy GmbH: KACO blueplanet 137 TL3 M1 WM OD IIPX {600V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-137-tl3-m1-wm-od-iipx-600v/) | 138,663 | 600.0 | 1300.0 | 98.69 |
| [**KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIK0 {480V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-110-tl3-m1-wm-od-iik0-480v/) | 109,765 | 480.0 | 1300.0 | 98.44 |
| [**KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}**](https://epri-peac.com/solar-equipment/inverters/kaco-new-energy-gmbh/kaco-new-energy-gmbh-kaco-blueplanet-110-tl3-m1-wm-od-iikx-480v/) | 109,765 | 480.0 | 1300.0 | 98.44 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for KACO new energy GmbH Solar Hardware?

Evaluate KACO new energy GmbH CEC certifications (109,765–151,228W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- KACO new energy GmbH supplies 8 inverter models on the CEC list; cold-climate roofs must check string Voc rise against the inverter's Vdcmax limit before finalizing module count.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### KACO new energy GmbH AC Conversion (109,765–151,228W AC)

Match KACO new energy GmbH MPPT channels and Vdcmax ceilings to third-party CEC panels, verifying NEC 705.12 120% panel busbar limits.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to KACO new energy GmbH photovoltaic and inverter hardware listed on the CEC registry.

### How many KACO new energy GmbH solar models are verified on the CEC list?

Our CEC archive indexes 8 KACO new energy GmbH equipment records (0 module series and 8 inverter models) spanning 109,765–151,228W AC. Check local building department permit requirements for Kaco New Energy Gmbh before finalizing component orders.

### What should homeowners check before approving KACO new energy GmbH equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Lion Energy CEC Solar Catalog (7,827–16,199W AC)](https://epri-peac.com/solar-equipment/brands/lion-energy/) [Orb Energy Private Limited CEC Solar Catalog (295–450W PV)](https://epri-peac.com/solar-equipment/brands/orb-energy-private-limited/) [Hounen Solar America Inc CEC Solar Catalog (395–580W PV)](https://epri-peac.com/solar-equipment/brands/hounen-solar-america-inc/) [OutBack Power CEC Solar Catalog (2,560–9,975W AC)](https://epri-peac.com/solar-equipment/brands/outback-power/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)