---
title: "Jackery Inc Solar Panels & Inverters (6 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/jackery-inc/
description: "CEC datasheets for Jackery Inc: 36–45W PV / 7,394–11,084W AC, 4 module series, 2 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Jackery Inc — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Jackery Inc holds 6 verified California Energy Commission (CEC) certifications including 4 module series and 2 grid-support inverter models (36–45W PV / 7,394–11,084W AC). Jackery Inc carries 4 module series ranging from 36 W to 45 W STC (median 40 W vs 385 W CEC fleet median; 13.7% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Jackery Inc

- **PV Module Series** : 4

- **Listed Inverters** : 2

- **Output Range** : 36–45W PV / 7,394–11,084W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Jackery Inc Solar Specifications Compare Across the CEC Catalog?

Technical overview of Jackery Inc solar certifications used by municipal inspectors and utilities to approve residential rooftop permits.

Independent third-party test metrics from the CEC confirm electrical ratings for Jackery Inc hardware under UL 1703/61730 and IEEE 1547 utility protocols. Typical PVUSA (PTC) real-world thermal output retains 91.8% of nameplate STC watts. Jackery Inc carries 4 module series ranging from 36 W to 45 W STC (median 40 W vs 385 W CEC fleet median; 13.7% median aperture efficiency, cell architecture Mono-c-Si). On the AC conversion side, Jackery Inc lists 2 CEC-certified inverters from 7,394 W to 11,084 W AC (97.4% median weighted CEC efficiency, including 2 battery-ready hybrid units). No active CPSC electrical recalls match Jackery Inc in our federal recall archive as of 2026.

## Which Jackery Inc PV Module Series Are CEC Certified? (4)

Every deduplicated Jackery Inc solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Jackery Inc Modules

Deduplicated CEC photovoltaic module series for Jackery Inc.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Jackery Inc JS-45A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-45a/) | 45.0 | 41.6 | 5.54 | 15.36 | 1 |
| [**Jackery Inc JS-42A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-42a/) | 42.0 | 38.8 | 5.54 | 14.33 | 1 |
| [**Jackery Inc JS-38A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-38a/) | 38.0 | 34.6 | 5.54 | 12.97 | 1 |
| [**Jackery Inc JS-36A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-36a/) | 36.0 | 32.7 | 5.54 | 12.29 | 1 |

## Which Jackery Inc Grid-Support Inverters Are Listed? (2)

Compare CEC-certified Jackery Inc inverters by continuous AC output watts, nominal grid voltage, maximum DC input ceiling, and weighted test efficiency.

Filter Jackery Inc Inverters

Verified CEC grid-support inverters from Jackery Inc.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Jackery Inc: GVI-HR-11K4-USG {240V}**](https://epri-peac.com/solar-equipment/inverters/jackery-inc/jackery-inc-gvi-hr-11k4-usg-240v/) | 11,084 | 240.0 | 450.0 | 97.42 |
| [**Jackery Inc: GVI-HR-7K6-USG {240V}**](https://epri-peac.com/solar-equipment/inverters/jackery-inc/jackery-inc-gvi-hr-7k6-usg-240v/) | 7,394 | 240.0 | 450.0 | 97.41 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jackery Inc Solar Hardware?

Evaluate Jackery Inc CEC certifications (36–45W PV / 7,394–11,084W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- With 4 module series and 2 inverter models, verify your exact wattage trim appears on your utility's accepted CEC sub-revision before permitting.
- Constrained roofs: Jackery Inc's median module aperture efficiency (13.7%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Unified Jackery Inc Solar + Inverter Spec

Use Jackery Inc modules and inverters together under unified CEC certification tracking while verifying NEC 705.12 backfeed clearance.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring Jackery Inc solar modules or inverters. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

### How many Jackery Inc solar models are verified on the CEC list?

Our CEC archive indexes 6 Jackery Inc equipment records (4 module series and 2 inverter models) spanning 36–45W PV / 7,394–11,084W AC. Check local building department permit requirements for Jackery Inc before finalizing component orders.

### What should homeowners check before approving Jackery Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Jackery Inc solar panels compared to CEC averages?

Across listed series, Jackery Inc modules show a median aperture efficiency of 13.7% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Jackery Inc.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[MANGO POWER TECH INC CEC Solar Catalog (400–11,933W AC)](https://epri-peac.com/solar-equipment/brands/mango-power-tech-inc/) [MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS CEC Solar Catalog (265–355W PV)](https://epri-peac.com/solar-equipment/brands/mar-solar-panel-imalati-ve-elektrik-urt-dag-prj-h-z-san-ve-t-c-as/) [Global Tech China Ltd CEC Solar Catalog (6,124–10,186W AC)](https://epri-peac.com/solar-equipment/brands/global-tech-china-ltd/) [Mundra Solar PV Limited (Adani) CEC Solar Catalog (370–610W PV)](https://epri-peac.com/solar-equipment/brands/mundra-solar-pv-limited-adani/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
