title: "Illuminate USA LLC Solar Panels and Inverters (2 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/illuminate-usa-llc/
description: "CEC datasheets for Illuminate USA LLC: 545–560W PV, 2 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Illuminate USA LLC — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Illuminate USA LLC holds 2 verified California Energy Commission (CEC) certifications including 2 module series (545–560W PV). Illuminate USA LLC carries 2 module series ranging from 545 W to 560 W STC (median 552 W vs 385 W CEC fleet median; 22.0% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Illuminate USA LLC

- **PV Module Series** : 2

- **Listed Inverters** : 0

- **Output Range** : 545–560W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Illuminate USA LLC Solar Specifications Compare Across the CEC Catalog?

How Illuminate USA LLC residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Illuminate USA LLC for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Illuminate USA LLC carries 2 module series ranging from 545 W to 560 W STC (median 552 W vs 385 W CEC fleet median; 22.0% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match Illuminate USA LLC in our federal recall archive as of 2026.

## Which Illuminate USA LLC PV Module Series Are CEC Certified? (2)

Every deduplicated Illuminate USA LLC solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Illuminate USA LLC Modules

Deduplicated CEC photovoltaic module series for Illuminate USA LLC.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Illuminate USA LLC IL5-72HBD-560M**](https://epri-peac.com/solar-equipment/modules/illuminate-usa-llc/illuminate-usa-llc-il5-72hbd-560m/) | 560.0 | 516.4 | 50.1 | 22.31 | 4 |
| [**Illuminate USA LLC IL5-72HBD-545M**](https://epri-peac.com/solar-equipment/modules/illuminate-usa-llc/illuminate-usa-llc-il5-72hbd-545m/) | 545.0 | 502.1 | 49.7 | 21.71 | 2 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Illuminate USA LLC Solar Hardware?

Evaluate Illuminate USA LLC CEC certifications (545–560W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Illuminate USA LLC certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Illuminate USA LLC Module + Third-Party Inverter

Pair Illuminate USA LLC modules (545–560W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering Illuminate USA LLC CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

### How many Illuminate USA LLC solar models are verified on the CEC list?

Our CEC archive indexes 2 Illuminate USA LLC equipment records (2 module series and 0 inverter models) spanning 545–560W PV. Check local building department permit requirements for Illuminate Usa Llc before finalizing component orders.

### What should homeowners check before approving Illuminate USA LLC equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Illuminate USA LLC solar panels compared to CEC averages?

Across listed series, Illuminate USA LLC modules show a median aperture efficiency of 22.0% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Illuminate Usa Llc.

## Related Pages

Compare Illuminate USA LLC against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[Jetion Solar (China) CEC Solar Catalog (260–310W PV)](https://epri-peac.com/solar-equipment/brands/jetion-solar-china/) [Jetion Solar (China) CoLtd CEC Solar Catalog (360–380W PV)](https://epri-peac.com/solar-equipment/brands/jetion-solar-china-coltd/) [Green Solutions (Chengdu) Co Ltd CEC Solar Catalog (10,490–11,930W AC)](https://epri-peac.com/solar-equipment/brands/green-solutions-chengdu-co-ltd/) [LS Energy Solutions LLC CEC Solar Catalog (139,449–140,485W AC)](https://epri-peac.com/solar-equipment/brands/ls-energy-solutions-llc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)