---
title: "Hyperion Solar Solar Panels & Inverters (36 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/hyperion-solar/
description: "CEC datasheets for Hyperion Solar: 390–550W PV, 36 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Hyperion Solar — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Hyperion Solar holds 36 verified California Energy Commission (CEC) certifications including 36 module series (390–550W PV). Hyperion Solar carries 36 module series ranging from 390 W to 550 W STC (median 468 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Hyperion Solar

- **PV Module Series** : 36

- **Listed Inverters** : 0

- **Output Range** : 390–550W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Hyperion Solar Solar Specifications Compare Across the CEC Catalog?

How Hyperion Solar residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Hyperion Solar for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Hyperion Solar carries 36 module series ranging from 390 W to 550 W STC (median 468 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match Hyperion Solar in our federal recall archive as of 2026.

## Which Hyperion Solar PV Module Series Are CEC Certified? (36)

Certified Hyperion Solar PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Filter Hyperion Solar Modules

Deduplicated CEC photovoltaic module series for Hyperion Solar.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Hyperion Solar HY-DH144P8-550**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-550/) | 550.0 | 511.6 | 49.9 | 21.32 | 1 |
| [**Hyperion Solar HY-DH144P8-550-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-550-b/) | 550.0 | 511.6 | 49.9 | 21.32 | 1 |
| [**Hyperion Solar HY-DH144P8-550-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-550-t/) | 550.0 | 511.6 | 49.9 | 21.32 | 1 |
| [**Hyperion Solar HY-WH144P8-550**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh144p8-550/) | 550.0 | 510.7 | 49.9 | 21.32 | 1 |
| [**Hyperion Solar HY-WH144P8-550-B {Blk}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh144p8-550-b-blk/) | 550.0 | 510.7 | 49.9 | 21.32 | 1 |
| [**Hyperion Solar HY-WH144P8-550-b {Wht}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh144p8-550-b-wht/) | 550.0 | 510.7 | 49.9 | 21.32 | 1 |
| [**Hyperion Solar HY-DH144P8-535**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-535/) | 535.0 | 497.3 | 49.45 | 20.74 | 5 |
| [**Hyperion Solar HY-DH144P8-535-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-535-b/) | 535.0 | 497.3 | 49.45 | 20.74 | 5 |
| [**Hyperion Solar HY-DH144P8-535-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh144p8-535-t/) | 535.0 | 497.3 | 49.45 | 20.74 | 5 |
| [**Hyperion Solar HY-WH144P8-535**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh144p8-535/) | 535.0 | 496.3 | 49.45 | 20.74 | 5 |
| [**Hyperion Solar HY-WH144P8-535-B {Blk}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh144p8-535-b-blk/) | 535.0 | 496.3 | 49.45 | 20.74 | 5 |
| [**Hyperion Solar HY-WH144P8-535-b {Wht}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh144p8-535-b-wht/) | 535.0 | 496.3 | 49.45 | 20.74 | 5 |
| [**Hyperion Solar HY-DH132P8-505**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-505/) | 505.0 | 469.8 | 45.72 | 21.31 | 2 |
| [**Hyperion Solar HY-DH132P8-505-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-505-b/) | 505.0 | 469.8 | 45.72 | 21.31 | 2 |
| [**Hyperion Solar HY-DH132P8-505-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-505-t/) | 505.0 | 469.8 | 45.72 | 21.31 | 2 |
| [**Hyperion Solar HY-DH132P8-490-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-490-b/) | 490.0 | 455.4 | 45.33 | 20.68 | 4 |
| [**Hyperion Solar HY-DH132P8-490-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-490-t/) | 490.0 | 455.4 | 45.33 | 20.68 | 4 |
| [**Hyperion Solar HY-DH132P8-480**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-480/) | 480.0 | 445.9 | 45.07 | 20.25 | 4 |
| [**Hyperion Solar HY-DH120P8-455**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh120p8-455/) | 455.0 | 423.1 | 41.36 | 21.06 | 3 |
| [**Hyperion Solar HY-DH120P8-455-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh120p8-455-b/) | 455.0 | 423.1 | 41.36 | 21.06 | 3 |
| [**Hyperion Solar HY-DH120P8-455-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh120p8-455-t/) | 455.0 | 423.1 | 41.36 | 21.06 | 3 |
| [**Hyperion Solar HY-DH120P8-440**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh120p8-440/) | 440.0 | 408.8 | 40.91 | 20.37 | 3 |
| [**Hyperion Solar HY-DH120P8-440-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh120p8-440-b/) | 440.0 | 408.8 | 40.91 | 20.37 | 3 |
| [**Hyperion Solar HY-DH120P8-440-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh120p8-440-t/) | 440.0 | 408.8 | 40.91 | 20.37 | 3 |
| [**Hyperion Solar HY-DH108P8-410**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh108p8-410/) | 410.0 | 381.2 | 37.32 | 21.03 | 4 |
| [**Hyperion Solar HY-DH108P8-410-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh108p8-410-b/) | 410.0 | 381.2 | 37.32 | 21.03 | 4 |
| [**Hyperion Solar HY-DH108P8-410-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh108p8-410-t/) | 410.0 | 381.2 | 37.32 | 21.03 | 4 |
| [**Hyperion Solar HY-WH108P8-410**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh108p8-410/) | 410.0 | 380.5 | 37.32 | 21.03 | 4 |
| [**Hyperion Solar HY-WH108P8-410-B {Blk}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh108p8-410-b-blk/) | 410.0 | 380.5 | 37.32 | 21.03 | 4 |
| [**Hyperion Solar HY-WH108P8-410-b {Wht}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh108p8-410-b-wht/) | 410.0 | 380.5 | 37.32 | 21.03 | 4 |
| [**Hyperion Solar HY-DH108P8-395-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh108p8-395-b/) | 395.0 | 366.9 | 36.98 | 20.26 | 2 |
| [**Hyperion Solar HY-DH108P8-395-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh108p8-395-t/) | 395.0 | 366.9 | 36.98 | 20.26 | 2 |
| [**Hyperion Solar HY-WH108P8-395**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh108p8-395/) | 395.0 | 366.2 | 36.98 | 20.26 | 2 |
| [**Hyperion Solar HY-WH108P8-395-B {Blk}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh108p8-395-b-blk/) | 395.0 | 366.2 | 36.98 | 20.26 | 2 |
| [**Hyperion Solar HY-WH108P8-395-b {Wht}**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-wh108p8-395-b-wht/) | 395.0 | 366.2 | 36.98 | 20.26 | 2 |
| [**Hyperion Solar HY-DH108P8-390**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh108p8-390/) | 390.0 | 362.1 | 36.85 | 20.0 | 2 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hyperion Solar Solar Hardware?

Evaluate Hyperion Solar CEC certifications (390–550W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Hyperion Solar certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Hyperion Solar Module + Third-Party Inverter

Pair Hyperion Solar modules (390–550W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering Hyperion Solar CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

### How many Hyperion Solar solar models are verified on the CEC list?

Our CEC archive indexes 36 Hyperion Solar equipment records (36 module series and 0 inverter models) spanning 390–550W PV. Check local building department permit requirements for Hyperion Solar before finalizing component orders.

### What should homeowners check before approving Hyperion Solar equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Hyperion Solar solar panels compared to CEC averages?

Across listed series, Hyperion Solar modules show a median aperture efficiency of 20.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Hyperion Solar.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[New East Solar Energy (Cambodia) CoLtd CEC Solar Catalog (295–730W PV)](https://epri-peac.com/solar-equipment/brands/new-east-solar-energy-cambodia-coltd/) [Sun Gold Power Inc CEC Solar Catalog (390–605W PV / 7,647–11,990W AC)](https://epri-peac.com/solar-equipment/brands/sun-gold-power-inc/) [Suntech Power CEC Solar Catalog (170–330W PV)](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Dehui Solar Power (Vietnam) CoLtd CEC Solar Catalog (320–550W PV)](https://epri-peac.com/solar-equipment/brands/dehui-solar-power-vietnam-coltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
