---
title: "Hounen Solar America Inc Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/hounen-solar-america-inc/
description: "CEC datasheets for Hounen Solar America Inc: 395–580W PV, 8 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Hounen Solar America Inc — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Hounen Solar America Inc holds 8 verified California Energy Commission (CEC) certifications including 8 module series (395–580W PV). Hounen Solar America Inc carries 8 module series ranging from 395 W to 580 W STC (median 475 W vs 385 W CEC fleet median; 21.1% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Hounen Solar America Inc

- **PV Module Series** : 8

- **Listed Inverters** : 0

- **Output Range** : 395–580W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Hounen Solar America Inc Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Hounen Solar America Inc photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Hounen Solar America Inc hardware for residential interconnection can verify exact DC and AC test data across 8 CEC records. Hounen Solar America Inc carries 8 module series ranging from 395 W to 580 W STC (median 475 W vs 385 W CEC fleet median; 21.1% median aperture efficiency, cell architecture Mono-c-Si). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match Hounen Solar America Inc in our federal recall archive as of 2026.

## Which Hounen Solar America Inc PV Module Series Are CEC Certified? (8)

Every deduplicated Hounen Solar America Inc solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Hounen Solar America Inc Modules

Deduplicated CEC photovoltaic module series for Hounen Solar America Inc.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Hounen Solar America Inc HNM7-UHLDD144-580/N**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-uhldd144-580-n/) | 580.0 | 545.1 | 51.5 | 22.48 | 3 |
| [**Hounen Solar America Inc HNM7-UHLDD144-565/N**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-uhldd144-565-n/) | 565.0 | 530.7 | 50.9 | 21.9 | 3 |
| [**Hounen Solar America Inc HNM7-SHDB144-555/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-shdb144-555-m/) | 555.0 | 519.8 | 50.4 | 21.51 | 2 |
| [**Hounen Solar America Inc HNM7-SHDB144-540/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-shdb144-540-m/) | 540.0 | 505.4 | 49.8 | 20.93 | 4 |
| [**Hounen Solar America Inc HNM7-SH108-410/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-sh108-410-m/) | 410.0 | 381.1 | 37.5 | 21.13 | 5 |
| [**Hounen Solar America Inc HNM7-SHDB108-410/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-shdb108-410-m/) | 410.0 | 381.2 | 37.5 | 21.13 | 4 |
| [**Hounen Solar America Inc HNM7-SH108-395/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-sh108-395-m/) | 395.0 | 366.8 | 36.9 | 20.36 | 2 |
| [**Hounen Solar America Inc HNM7-SHDB108-395/M**](https://epri-peac.com/solar-equipment/modules/hounen-solar-america-inc/hounen-solar-america-inc-hnm7-shdb108-395-m/) | 395.0 | 366.8 | 36.9 | 20.36 | 2 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Hounen Solar America Inc Solar Hardware?

Evaluate Hounen Solar America Inc CEC certifications (395–580W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Hounen Solar America Inc certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Hounen Solar America Inc Module + Third-Party Inverter

Pair Hounen Solar America Inc modules (395–580W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering Hounen Solar America Inc CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

### How many Hounen Solar America Inc solar models are verified on the CEC list?

Our CEC archive indexes 8 Hounen Solar America Inc equipment records (8 module series and 0 inverter models) spanning 395–580W PV. Check local building department permit requirements for Hounen Solar America Inc before finalizing component orders.

### What should homeowners check before approving Hounen Solar America Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Hounen Solar America Inc solar panels compared to CEC averages?

Across listed series, Hounen Solar America Inc modules show a median aperture efficiency of 21.1% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Hounen Solar America Inc.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[KACO new energy GmbH CEC Solar Catalog (109,765–151,228W AC)](https://epri-peac.com/solar-equipment/brands/kaco-new-energy-gmbh/) [Lion Energy CEC Solar Catalog (7,827–16,199W AC)](https://epri-peac.com/solar-equipment/brands/lion-energy/) [Gamesa Electric CEC Solar Catalog (3,418,394–4,654,418W AC)](https://epri-peac.com/solar-equipment/brands/gamesa-electric/) [Orb Energy Private Limited CEC Solar Catalog (295–450W PV)](https://epri-peac.com/solar-equipment/brands/orb-energy-private-limited/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
