title: "Gintung Energy Solar Panels & Inverters (64 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/gintung-energy/
description: "CEC datasheets for Gintung Energy: 120–325W PV, 64 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Gintung Energy — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Gintung Energy holds 64 verified California Energy Commission (CEC) certifications including 64 module series (120–325W PV). Gintung Energy carries 64 module series ranging from 120 W to 325 W STC (median 235 W vs 385 W CEC fleet median; 15.0% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Gintung Energy

- **PV Module Series** : 64

- **Listed Inverters** : 0

- **Output Range** : 120–325W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Gintung Energy Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Gintung Energy photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Gintung Energy hardware for residential interconnection can verify exact DC and AC test data across 64 CEC records. Gintung Energy carries 64 module series ranging from 120 W to 325 W STC (median 235 W vs 385 W CEC fleet median; 15.0% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match Gintung Energy in our federal recall archive as of 2026.

## Which Gintung Energy PV Module Series Are CEC Certified? (64)

Filter certified Gintung Energy solar panels by series name, nameplate STC capacity, PTC output, open-circuit voltage, or conversion efficiency.

Filter Gintung Energy Modules

Deduplicated CEC photovoltaic module series for Gintung Energy.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-325G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6m/) | 325.0 | 286.7 | 45.35 | 16.62 | 1 |
| [**Gintung Energy ASEC-325G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-325g6s/) | 325.0 | 285.5 | 45.48 | 16.62 | 1 |
| [**Gintung Energy GTEC-325G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6m/) | 325.0 | 286.7 | 45.35 | 16.62 | 1 |
| [**Gintung Energy GTEC-325G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-325g6s/) | 325.0 | 285.5 | 45.48 | 16.62 | 1 |
| [**Gintung Energy ASEC-310G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6m/) | 310.0 | 273.0 | 44.97 | 15.85 | 5 |
| [**Gintung Energy ASEC-310G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-310g6s/) | 310.0 | 271.8 | 45.22 | 15.85 | 5 |
| [**Gintung Energy GTEC-310G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-310g6m/) | 310.0 | 273.0 | 44.97 | 15.85 | 5 |
| [**Gintung Energy GTEC-310G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-310g6s/) | 310.0 | 271.8 | 45.22 | 15.85 | 5 |
| [**Gintung Energy GTEC-290G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6m/) | 290.0 | 259.7 | 44.61 | 14.83 | 4 |
| [**Gintung Energy GTEC-290G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6s/) | 290.0 | 260.2 | 44.84 | 14.83 | 4 |
| [**Gintung Energy ASEC-285G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6m/) | 285.0 | 255.1 | 44.53 | 14.57 | 5 |
| [**Gintung Energy ASEC-285G6M6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6m6b/) | 285.0 | 251.1 | 41.75 | 16.07 | 5 |
| [**Gintung Energy ASEC-285G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6s/) | 285.0 | 255.6 | 44.69 | 14.57 | 5 |
| [**Gintung Energy ASEC-285G6S6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6s6b/) | 285.0 | 250.0 | 41.29 | 16.07 | 5 |
| [**Gintung Energy GTEC-285G6M6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-285g6m6b/) | 285.0 | 251.1 | 41.75 | 16.07 | 5 |
| [**Gintung Energy GTEC-285G6S6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-285g6s6b/) | 285.0 | 250.0 | 41.29 | 16.07 | 5 |
| [**Gintung Energy ASEC-265G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-265g6s/) | 265.0 | 237.2 | 44.12 | 13.55 | 4 |
| [**Gintung Energy GTEC-265G6M6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-265g6m6b/) | 265.0 | 232.9 | 41.35 | 14.94 | 3 |
| [**Gintung Energy GTEC-265G6S6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-265g6s6b/) | 265.0 | 231.9 | 40.88 | 14.94 | 3 |
| [**Gintung Energy ASEC-260G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6m/) | 260.0 | 232.1 | 43.84 | 13.29 | 5 |
| [**Gintung Energy ASEC-260G6M6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6m6a/) | 260.0 | 229.1 | 37.78 | 16.14 | 5 |
| [**Gintung Energy ASEC-260G6M6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6m6b/) | 260.0 | 228.4 | 41.21 | 14.66 | 5 |
| [**Gintung Energy ASEC-260G6S6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6s6a/) | 260.0 | 228.1 | 37.42 | 16.14 | 5 |
| [**Gintung Energy ASEC-260G6S6B**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6s6b/) | 260.0 | 227.4 | 40.73 | 14.66 | 5 |
| [**Gintung Energy GTEC-260G6M6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-260g6m6a/) | 260.0 | 229.1 | 37.78 | 16.14 | 5 |
| [**Gintung Energy GTEC-260G6S6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-260g6s6a/) | 260.0 | 228.1 | 37.42 | 16.14 | 5 |
| [**Gintung Energy ASEC-245G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-245g6m/) | 245.0 | 218.4 | 43.39 | 12.53 | 1 |
| [**Gintung Energy ASEC-245G6M6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-245g6m6a/) | 245.0 | 219.5 | 37.31 | 15.21 | 2 |
| [**Gintung Energy ASEC-245G6S6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-245g6s6a/) | 245.0 | 220.0 | 37.14 | 15.21 | 2 |
| [**Gintung Energy GTEC-245G6M6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-245g6m6a/) | 245.0 | 219.5 | 37.31 | 15.21 | 2 |
| [**Gintung Energy GTEC-245G6S6A**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-245g6s6a/) | 245.0 | 220.0 | 37.14 | 15.21 | 2 |
| [**Gintung Energy ASEC-235G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6m69/) | 235.0 | 207.0 | 34.06 | 16.04 | 5 |
| [**Gintung Energy ASEC-235G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6s69/) | 235.0 | 206.2 | 34.13 | 16.04 | 5 |
| [**Gintung Energy GTEC-235G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-235g6m69/) | 235.0 | 207.0 | 34.06 | 16.04 | 5 |
| [**Gintung Energy GTEC-235G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-235g6s69/) | 235.0 | 206.2 | 34.13 | 16.04 | 5 |
| [**Gintung Energy ASEC-230G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-230g6m/) | 230.0 | 205.7 | 36.87 | 14.28 | 3 |
| [**Gintung Energy ASEC-230G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-230g6s/) | 230.0 | 206.2 | 36.75 | 14.28 | 3 |
| [**Gintung Energy ASEC-220G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-220g6m/) | 220.0 | 196.5 | 36.57 | 13.66 | 2 |
| [**Gintung Energy ASEC-220G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-220g6m69/) | 220.0 | 197.1 | 33.75 | 15.02 | 2 |
| [**Gintung Energy ASEC-220G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-220g6s/) | 220.0 | 197.0 | 36.53 | 13.66 | 2 |
| [**Gintung Energy ASEC-220G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-220g6s69/) | 220.0 | 197.5 | 33.86 | 15.02 | 2 |
| [**Gintung Energy GTEC-220G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-220g6m69/) | 220.0 | 197.1 | 33.75 | 15.02 | 2 |
| [**Gintung Energy GTEC-220G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-220g6s69/) | 220.0 | 197.5 | 33.86 | 15.02 | 2 |
| [**Gintung Energy ASEC-210G6M68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-210g6m68/) | 210.0 | 185.0 | 30.14 | 16.1 | 5 |
| [**Gintung Energy ASEC-210G6S68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-210g6s68/) | 210.0 | 184.3 | 30.14 | 16.1 | 5 |
| [**Gintung Energy GTEC-210G6M68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-210g6m68/) | 210.0 | 185.0 | 30.14 | 16.1 | 5 |
| [**Gintung Energy GTEC-210G6S68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-210g6s68/) | 210.0 | 184.3 | 30.14 | 16.1 | 5 |
| [**Gintung Energy ASEC-205G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-205g6m/) | 205.0 | 181.5 | 33.58 | 14.57 | 3 |
| [**Gintung Energy ASEC-205G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-205g6s/) | 205.0 | 183.6 | 33.64 | 14.57 | 3 |
| [**Gintung Energy ASEC-195G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-195g6m/) | 195.0 | 172.4 | 32.94 | 13.86 | 2 |
| [**Gintung Energy ASEC-195G6M68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-195g6m68/) | 195.0 | 174.6 | 29.87 | 14.95 | 2 |
| [**Gintung Energy ASEC-195G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-195g6s/) | 195.0 | 174.4 | 32.95 | 13.86 | 2 |
| [**Gintung Energy ASEC-195G6S68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-195g6s68/) | 195.0 | 175.0 | 29.82 | 14.95 | 2 |
| [**Gintung Energy GTEC-195G6M68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-195g6m68/) | 195.0 | 174.6 | 29.87 | 14.95 | 2 |
| [**Gintung Energy GTEC-195G6S68**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-195g6s68/) | 195.0 | 175.0 | 29.82 | 14.95 | 2 |
| [**Gintung Energy ASEC-180G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-180g6m/) | 180.0 | 160.5 | 29.51 | 13.8 | 3 |
| [**Gintung Energy ASEC-180G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-180g6s/) | 180.0 | 159.7 | 29.73 | 13.8 | 3 |
| [**Gintung Energy ASEC-155G6M49**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-155g6m49/) | 155.0 | 136.5 | 22.53 | 15.71 | 2 |
| [**Gintung Energy ASEC-155G6S49**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-155g6s49/) | 155.0 | 135.9 | 22.58 | 15.71 | 2 |
| [**Gintung Energy ASEC-145G6M49**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-145g6m49/) | 145.0 | 127.4 | 22.32 | 14.7 | 1 |
| [**Gintung Energy ASEC-145G6S49**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-145g6s49/) | 145.0 | 126.8 | 22.38 | 14.7 | 1 |
| [**Gintung Energy ASEC-135G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-135g6m/) | 135.0 | 120.6 | 22.1 | 13.74 | 4 |
| [**Gintung Energy ASEC-135G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-135g6s/) | 135.0 | 120.9 | 22.15 | 13.74 | 4 |
| [**Gintung Energy ASEC-120G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-120g6m/) | 120.0 | 106.9 | 21.6 | 12.21 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Gintung Energy Solar Hardware?

Evaluate Gintung Energy CEC certifications (120–325W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Gintung Energy certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Gintung Energy's median module aperture efficiency (15.0%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Gintung Energy Module + Third-Party Inverter

Pair Gintung Energy modules (120–325W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical answers covering Gintung Energy CEC certifications, winter voltage headroom, and panel-busbar interconnection checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

### How many Gintung Energy solar models are verified on the CEC list?

Our CEC archive indexes 64 Gintung Energy equipment records (64 module series and 0 inverter models) spanning 120–325W PV. Check local building department permit requirements for Gintung Energy before finalizing component orders.

### What should homeowners check before approving Gintung Energy equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Gintung Energy solar panels compared to CEC averages?

Across listed series, Gintung Energy modules show a median aperture efficiency of 15.0% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[Jiangsu Runergy New Energy Technology Co Ltd CEC Solar Catalog (390–640W PV)](https://epri-peac.com/solar-equipment/brands/jiangsu-runergy-new-energy-technology-co-ltd/) [Heliene CEC Solar Catalog (100–645W PV)](https://epri-peac.com/solar-equipment/brands/heliene/) [Centrosolar America CEC Solar Catalog (140–350W PV)](https://epri-peac.com/solar-equipment/brands/centrosolar-america/) [CertainTeed CEC Solar Catalog (67–455W PV)](https://epri-peac.com/solar-equipment/brands/certainteed/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)