title: "Generac Power Systems Inc Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/generac-power-systems-inc/
description: "CEC datasheets for Generac Power Systems Inc: 380–11,748W AC, 0 module series, 11 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Generac Power Systems Inc — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Generac Power Systems Inc holds 11 verified California Energy Commission (CEC) certifications and 11 grid-support inverter models (380–11,748W AC). On the AC conversion side, Generac Power Systems Inc lists 11 CEC-certified inverters from 380 W to 11,748 W AC (96.8% median weighted CEC efficiency, including 4 battery-ready hybrid units).

- **Manufacturer** : Generac Power Systems Inc

- **PV Module Series** : 0

- **Listed Inverters** : 11

- **Output Range** : 380–11,748W AC

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Generac Power Systems Inc Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Generac Power Systems Inc photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Generac Power Systems Inc hardware for residential interconnection can verify exact DC and AC test data across 11 CEC records. On the AC conversion side, Generac Power Systems Inc lists 11 CEC-certified inverters from 380 W to 11,748 W AC (96.8% median weighted CEC efficiency, including 4 battery-ready hybrid units). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. CPSC cross-check flags 5 historical electrical recall entry matching Generac Power Systems Inc; verify serial-number clearance before purchasing older used inventory.

## Which Generac Power Systems Inc Grid-Support Inverters Are Listed? (11)

Review every Generac Power Systems Inc grid-support and hybrid inverter model below to confirm NEC 705.12 backfeed breaker sizing and string voltage headroom.

Filter Generac Power Systems Inc Inverters

Verified CEC grid-support inverters from Generac Power Systems Inc.

| Inverter Model | AC Output (W) | Vac (V) | Max DC (V) | CEC Eff (%) |
|---|---|---|---|---|
| [**Generac Power Systems Inc: XVT114G03 {208V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-xvt114g03-208v/) | 11,748 | 208.0 | 420.0 | 97.19 |
| [**Generac Power Systems Inc: APKE00075 {240V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-apke00075-240v/) | 11,473 | 240.0 | 420.0 | 97.93 |
| [**Generac Power Systems Inc: X11402 {208V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-x11402-208v/) | 11,180 | 208.0 | 420.0 | 96.98 |
| [**Generac Power Systems Inc: XVT076A03 {240V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-xvt076a03-240v/) | 7,606 | 240.0 | 420.0 | 96.19 |
| [**Generac Power Systems Inc: X7602 {240V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-x7602-240v/) | 7,586 | 240.0 | 420.0 | 96.98 |
| [**Generac Power Systems Inc: PM-820 {208V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-pm-820-208v/) | 820 | 208.0 | 40.0 | 96.61 |
| [**Generac Power Systems Inc: PM-820 {240V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-pm-820-240v/) | 820 | 240.0 | 40.0 | 96.84 |
| [**Generac Power Systems Inc: CP-760-V2 {208V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-cp-760-v2-208v/) | 762 | 208.0 | 72.0 | 96.44 |
| [**Generac Power Systems Inc: CP-760-V2 {240V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-cp-760-v2-240v/) | 761 | 240.0 | 72.0 | 96.79 |
| [**Generac Power Systems Inc: CP-380-V2 {208V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-cp-380-v2-208v/) | 380 | 208.0 | 36.0 | 96.74 |
| [**Generac Power Systems Inc: CP-380-V2 {240V}**](https://epri-peac.com/solar-equipment/inverters/generac-power-systems-inc/generac-power-systems-inc-cp-380-v2-240v/) | 380 | 240.0 | 36.0 | 96.91 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Generac Power Systems Inc Solar Hardware?

Evaluate Generac Power Systems Inc CEC certifications (380–11,748W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Generac Power Systems Inc supplies 11 inverter models on the CEC list; cold-climate roofs must check string Voc rise against the inverter's Vdcmax limit before finalizing module count.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Generac Power Systems Inc AC Conversion (380–11,748W AC)

Match Generac Power Systems Inc MPPT channels and Vdcmax ceilings to third-party CEC panels, verifying NEC 705.12 120% panel busbar limits.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Generac Power Systems Inc solar equipment.

### How many Generac Power Systems Inc solar models are verified on the CEC list?

Our CEC archive indexes 11 Generac Power Systems Inc equipment records (0 module series and 11 inverter models) spanning 380–11,748W AC. Check local building department permit requirements for Generac Power Systems Inc before finalizing component orders.

### What should homeowners check before approving Generac Power Systems Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

## Related Pages

Navigate to peer solar manufacturers in the same wattage output tier or review side-by-side solar code comparisons and NEC tools.

[Juli New Energy CEC Solar Catalog (165–310W PV)](https://epri-peac.com/solar-equipment/brands/juli-new-energy/) [Mate Solar Co Ltd CEC Solar Catalog (395–685W PV)](https://epri-peac.com/solar-equipment/brands/mate-solar-co-ltd/) [GAF Energy LLC CEC Solar Catalog (45–58W PV)](https://epri-peac.com/solar-equipment/brands/gaf-energy-llc/) [PANASONIC CORPORATION OF NORTH AMERICA CEC Solar Catalog (350–430W PV / 7,608W AC)](https://epri-peac.com/solar-equipment/brands/panasonic-corporation-of-north-america/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)