title: "GAF Energy LLC Solar Panels & Inverters (11 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/gaf-energy-llc/
description: "CEC datasheets for GAF Energy LLC: 45–58W PV, 11 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# GAF Energy LLC — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

GAF Energy LLC holds 11 verified California Energy Commission (CEC) certifications including 11 module series (45–58W PV). GAF Energy LLC carries 11 module series ranging from 45 W to 58 W STC (median 56 W vs 385 W CEC fleet median; 8.0% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : GAF Energy LLC

- **PV Module Series** : 11

- **Listed Inverters** : 0

- **Output Range** : 45–58W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do GAF Energy LLC Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for GAF Energy LLC.

GAF Energy LLC participates in the California Energy Commission (CEC) Solar Equipment List with 11 total certified hardware listings. GAF Energy LLC carries 11 module series ranging from 45 W to 58 W STC (median 56 W vs 385 W CEC fleet median; 8.0% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match GAF Energy LLC in our federal recall archive as of 2026.

## Which GAF Energy LLC PV Module Series Are CEC Certified? (11)

Every deduplicated GAF Energy LLC solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter GAF Energy LLC Modules

Deduplicated CEC photovoltaic module series for GAF Energy LLC.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**GAF Energy LLC TLS-2-58**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2-58/) | 58.0 | 49.9 | 11.04 | 8.29 | 1 |
| [**GAF Energy LLC TLS-2J-58**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2j-58/) | 58.0 | 49.9 | 11.04 | 8.29 | 1 |
| [**GAF Energy LLC TLS-2**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2/) | 57.0 | 49.0 | 10.85 | 8.14 | 1 |
| [**GAF Energy LLC TLS-2J**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2j/) | 57.0 | 49.0 | 10.85 | 8.14 | 1 |
| [**GAF Energy LLC TLS-2-56**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2-56/) | 56.0 | 48.1 | 10.66 | 8.0 | 1 |
| [**GAF Energy LLC TLS-2J-56**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-2j-56/) | 56.0 | 48.1 | 10.66 | 8.0 | 1 |
| [**GAF Energy LLC TLS-13**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-13/) | 48.0 | 40.5 | 10.9 | 6.86 | 1 |
| [**GAF Energy LLC TLS-12**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-12/) | 47.0 | 40.0 | 10.9 | 6.71 | 1 |
| [**GAF Energy LLC TLS-1**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-1/) | 46.0 | 41.4 | 10.9 | 6.57 | 1 |
| [**GAF Energy LLC TLS-11**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-11/) | 46.0 | 41.4 | 10.9 | 6.57 | 1 |
| [**GAF Energy LLC 294000328**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-294000328/) | 45.0 | 38.6 | 10.89 | 6.43 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for GAF Energy LLC Solar Hardware?

Evaluate GAF Energy LLC CEC certifications (45–58W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- GAF Energy LLC certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: GAF Energy LLC's median module aperture efficiency (8.0%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### GAF Energy LLC Module + Third-Party Inverter

Pair GAF Energy LLC modules (45–58W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring GAF Energy LLC solar modules or inverters. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

### How many GAF Energy LLC solar models are verified on the CEC list?

Our CEC archive indexes 11 GAF Energy LLC equipment records (11 module series and 0 inverter models) spanning 45–58W PV. Check local building department permit requirements for Gaf Energy Llc before finalizing component orders.

### What should homeowners check before approving GAF Energy LLC equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are GAF Energy LLC solar panels compared to CEC averages?

Across listed series, GAF Energy LLC modules show a median aperture efficiency of 8.0% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gaf Energy Llc.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Generac Power Systems Inc CEC Solar Catalog (380–11,748W AC)](https://epri-peac.com/solar-equipment/brands/generac-power-systems-inc/) [Juli New Energy CEC Solar Catalog (165–310W PV)](https://epri-peac.com/solar-equipment/brands/juli-new-energy/) [Flextronics CEC Solar Catalog (252–340W PV)](https://epri-peac.com/solar-equipment/brands/flextronics/) [Mate Solar Co Ltd CEC Solar Catalog (395–685W PV)](https://epri-peac.com/solar-equipment/brands/mate-solar-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)