title: "Exiom Solution S A Solar Panels and Inverters (7 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/exiom-solution-s-a/
description: "CEC datasheets for Exiom Solution S A: 410–550W PV, 7 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Exiom Solution S A — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Exiom Solution S A holds 7 verified California Energy Commission (CEC) certifications including 7 module series (410–550W PV). Exiom Solution S A carries 7 module series ranging from 410 W to 550 W STC (median 545 W vs 385 W CEC fleet median; 21.3% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Exiom Solution S A

- **PV Module Series** : 7

- **Listed Inverters** : 0

- **Output Range** : 410–550W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Exiom Solution S A Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Exiom Solution S A photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Exiom Solution S A hardware for residential interconnection can verify exact DC and AC test data across 7 CEC records. Exiom Solution S A carries 7 module series ranging from 410 W to 550 W STC (median 545 W vs 385 W CEC fleet median; 21.3% median aperture efficiency, cell architecture Mono-c-Si). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match Exiom Solution S A in our federal recall archive as of 2026.

## Which Exiom Solution S A PV Module Series Are CEC Certified? (7)

Every deduplicated Exiom Solution S A solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Exiom Solution S A Modules

Deduplicated CEC photovoltaic module series for Exiom Solution S A.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Exiom Solution S A EX545-144MH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex545-144mh/) | 550.0 | 508.9 | 49.9 | 21.65 | 1 |
| [**Exiom Solution S A EX550-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144bmh-dg/) | 550.0 | 513.9 | 49.9 | 21.32 | 1 |
| [**Exiom Solution S A EX550-144M-BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144m-bmh/) | 550.0 | 515.4 | 49.9 | 21.32 | 1 |
| [**Exiom Solution S A EX545-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex545-144bmh-dg/) | 545.0 | 509.1 | 49.8 | 21.12 | 1 |
| [**Exiom Solution S A EX545-144M-BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex545-144m-bmh/) | 545.0 | 510.6 | 49.8 | 21.12 | 1 |
| [**Exiom Solution S A EX550-144MH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144mh/) | 545.0 | 504.2 | 49.8 | 21.46 | 1 |
| [**Exiom Solution S A EX410-108BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex410-108bmh/) | 410.0 | 382.4 | 37.5 | 21.13 | 2 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Exiom Solution S A Solar Hardware?

Evaluate Exiom Solution S A CEC certifications (410–550W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Exiom Solution S A certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Exiom Solution S A Module + Third-Party Inverter

Pair Exiom Solution S A modules (410–550W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring Exiom Solution S A solar modules or inverters. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

### How many Exiom Solution S A solar models are verified on the CEC list?

Our CEC archive indexes 7 Exiom Solution S A equipment records (7 module series and 0 inverter models) spanning 410–550W PV. Check local building department permit requirements for Exiom Solution S.A. before finalizing component orders.

### What should homeowners check before approving Exiom Solution S A equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Exiom Solution S A solar panels compared to CEC averages?

Across listed series, Exiom Solution S A modules show a median aperture efficiency of 21.3% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Exiom Solution S.A..

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to Exiom Solution S A.

[IMPERIAL STAR SOLAR(CAMBODIA) CO LTD CEC Solar Catalog (390–555W PV)](https://epri-peac.com/solar-equipment/brands/imperial-star-solar-cambodia-co-ltd/) [Kowint Energy (Shenzhen) Co Ltd CEC Solar Catalog (8,111–125,015W AC)](https://epri-peac.com/solar-equipment/brands/kowint-energy-shenzhen-co-ltd/) [CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CEC Solar Catalog (450–675W PV)](https://epri-peac.com/solar-equipment/brands/cw-enerj-m-hend-sl-k-t-caret-ve-sanay-anon-m-rket/) [Miasole CEC Solar Catalog (115–500W PV)](https://epri-peac.com/solar-equipment/brands/miasole/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)