title: "Ergosun Holdings LLC Solar Panels and Inverters"
url: https://epri-peac.com/solar-equipment/brands/ergosun-holdings-llc/
description: "CEC datasheets for Ergosun Holdings LLC: 17–55W PV, 2 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Ergosun Holdings LLC — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Ergosun Holdings LLC holds 2 verified California Energy Commission (CEC) certifications including 2 module series (17–55W PV). Ergosun Holdings LLC carries 2 module series ranging from 17 W to 55 W STC (median 36 W vs 385 W CEC fleet median; 16.1% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Ergosun Holdings LLC

- **PV Module Series** : 2

- **Listed Inverters** : 0

- **Output Range** : 17–55W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Ergosun Holdings LLC Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for Ergosun Holdings LLC.

Ergosun Holdings LLC participates in the California Energy Commission (CEC) Solar Equipment List with 2 total certified hardware listings. Ergosun Holdings LLC carries 2 module series ranging from 17 W to 55 W STC (median 36 W vs 385 W CEC fleet median; 16.1% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match Ergosun Holdings LLC in our federal recall archive as of 2026.

## Which Ergosun Holdings LLC PV Module Series Are CEC Certified? (2)

Certified Ergosun Holdings LLC PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Filter Ergosun Holdings LLC Modules

Deduplicated CEC photovoltaic module series for Ergosun Holdings LLC.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Ergosun Holdings LLC Ergosun 55W**](https://epri-peac.com/solar-equipment/modules/ergosun-holdings-llc/ergosun-holdings-llc-ergosun-55w/) | 55.0 | 52.2 | 14.5 | 19.64 | 1 |
| [**Ergosun Holdings LLC Ergosun 175W Black**](https://epri-peac.com/solar-equipment/modules/ergosun-holdings-llc/ergosun-holdings-llc-ergosun-175w-black/) | 17.5 | 16.5 | 12.8 | 12.59 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Ergosun Holdings LLC Solar Hardware?

Evaluate Ergosun Holdings LLC CEC certifications (17–55W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Ergosun Holdings LLC certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Ergosun Holdings LLC's median module aperture efficiency (16.1%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Ergosun Holdings LLC Module + Third-Party Inverter

Pair Ergosun Holdings LLC modules (17–55W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring Ergosun Holdings LLC solar modules or inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

### How many Ergosun Holdings LLC solar models are verified on the CEC list?

Our CEC archive indexes 2 Ergosun Holdings LLC equipment records (2 module series and 0 inverter models) spanning 17–55W PV. Check local building department permit requirements for Ergosun Holdings Llc before finalizing component orders.

### What should homeowners check before approving Ergosun Holdings LLC equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Ergosun Holdings LLC solar panels compared to CEC averages?

Across listed series, Ergosun Holdings LLC modules show a median aperture efficiency of 16.1% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Ergosun Holdings Llc.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Eternalplanet Energy Co Ltd CEC Solar Catalog (11,349W AC)](https://epri-peac.com/solar-equipment/brands/eternalplanet-energy-co-ltd/) [FranklinWH Energy Storage Inc CEC Solar Catalog (9,776–9,785W AC)](https://epri-peac.com/solar-equipment/brands/franklinwh-energy-storage-inc/) [CE+T America Inc CEC Solar Catalog (29,990W AC)](https://epri-peac.com/solar-equipment/brands/ce-t-america-inc/) [General Motors Energy LLC CEC Solar Catalog (10,056–11,588W AC)](https://epri-peac.com/solar-equipment/brands/general-motors-energy-llc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)