title: "Energy America LLC Solar Panels and Inverters (4 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/energy-america-llc/
description: "CEC datasheets for Energy America LLC: 395–555W PV, 4 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Energy America LLC — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Energy America LLC holds 4 verified California Energy Commission (CEC) certifications including 4 module series (395–555W PV). Energy America LLC carries 4 module series ranging from 395 W to 555 W STC (median 475 W vs 385 W CEC fleet median; 21.0% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Energy America LLC

- **PV Module Series** : 4

- **Listed Inverters** : 0

- **Output Range** : 395–555W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Energy America LLC Solar Specifications Compare Across the CEC Catalog?

Portfolio capacity, conversion efficiency, and safety recall screening for Energy America LLC solar hardware certified under California Energy Commission standards.

Flagship CEC certification records for Energy America LLC include Energy America LLC EA-ZLK7-SHDB144-555/M alongside 4 verified brand entries. Energy America LLC carries 4 module series ranging from 395 W to 555 W STC (median 475 W vs 385 W CEC fleet median; 21.0% median aperture efficiency, cell architecture Mono-c-Si). Permitting inspectors cross-reference exact CEC model strings on utility interconnection packets. No active CPSC electrical recalls match Energy America LLC in our federal recall archive as of 2026.

## Which Energy America LLC PV Module Series Are CEC Certified? (4)

Every deduplicated Energy America LLC solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Energy America LLC Modules

Deduplicated CEC photovoltaic module series for Energy America LLC.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Energy America LLC EA-ZLK7-SHDB144-555/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb144-555-m/) | 555.0 | 519.7 | 50.4 | 21.51 | 2 |
| [**Energy America LLC EA-ZLK7-SHDB144-540/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb144-540-m/) | 540.0 | 505.3 | 49.8 | 20.93 | 4 |
| [**Energy America LLC EA-ZLK7-SHDB108-410/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb108-410-m/) | 410.0 | 381.2 | 37.5 | 21.13 | 4 |
| [**Energy America LLC EA-ZLK7-SHDB108-395/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb108-395-m/) | 395.0 | 366.8 | 36.9 | 20.36 | 2 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Energy America LLC Solar Hardware?

Evaluate Energy America LLC CEC certifications (395–555W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Energy America LLC certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Energy America LLC Module + Third-Party Inverter

Pair Energy America LLC modules (395–555W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Energy America LLC photovoltaic and inverter hardware listed on the CEC registry.

### How many Energy America LLC solar models are verified on the CEC list?

Our CEC archive indexes 4 Energy America LLC equipment records (4 module series and 0 inverter models) spanning 395–555W PV. Check local building department permit requirements for Energy America Llc before finalizing component orders.

### What should homeowners check before approving Energy America LLC equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Energy America LLC solar panels compared to CEC averages?

Across listed series, Energy America LLC modules show a median aperture efficiency of 21.0% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Energy America Llc.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Hanersun Technology Co Ltd CEC Solar Catalog (345–430W PV)](https://epri-peac.com/solar-equipment/brands/hanersun-technology-co-ltd/) [Jiangsu RCT Power Energy Technology Co Ltd CEC Solar Catalog (7,015–8,032W AC)](https://epri-peac.com/solar-equipment/brands/jiangsu-rct-power-energy-technology-co-ltd/) [EcoFlow Inc CEC Solar Catalog (11,443–24,291W AC)](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/) [LIGHT&HOPE ENERGY COLTD CEC Solar Catalog (395–455W PV)](https://epri-peac.com/solar-equipment/brands/light-hope-energy-coltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)