---
title: "Du Pont Apollo Solar Panels & Inverters (4 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/du-pont-apollo/
description: "CEC datasheets for Du Pont Apollo: 95–133W PV, 4 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Du Pont Apollo — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Du Pont Apollo holds 4 verified California Energy Commission (CEC) certifications including 4 module series (95–133W PV). Du Pont Apollo carries 4 module series ranging from 95 W to 133 W STC (median 104 W vs 385 W CEC fleet median; 6.7% median aperture efficiency, cell architecture Thin Film).

- **Manufacturer** : Du Pont Apollo

- **PV Module Series** : 4

- **Listed Inverters** : 0

- **Output Range** : 95–133W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Du Pont Apollo Solar Specifications Compare Across the CEC Catalog?

How Du Pont Apollo residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Du Pont Apollo for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Du Pont Apollo carries 4 module series ranging from 95 W to 133 W STC (median 104 W vs 385 W CEC fleet median; 6.7% median aperture efficiency, cell architecture Thin Film). No active CPSC electrical recalls match Du Pont Apollo in our federal recall archive as of 2026.

## Which Du Pont Apollo PV Module Series Are CEC Certified? (4)

Filter certified Du Pont Apollo solar panels by series name, nameplate STC capacity, PTC output, open-circuit voltage, or conversion efficiency.

Filter Du Pont Apollo Modules

Deduplicated CEC photovoltaic module series for Du Pont Apollo.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Du Pont Apollo DA133-C2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da133-c2/) | 133.0 | 122.4 | 156.73 | 8.64 | 3 |
| [**Du Pont Apollo DA105-A2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da105-a2/) | 105.0 | 95.5 | 100.0 | 6.82 | 2 |
| [**Du Pont Apollo DA102-A6**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da102-a6/) | 102.0 | 96.1 | 100.0 | 6.62 | 3 |
| [**Du Pont Apollo DA095-A2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da095-a2/) | 95.0 | 86.3 | 100.0 | 6.17 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Du Pont Apollo Solar Hardware?

Evaluate Du Pont Apollo CEC certifications (95–133W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Du Pont Apollo certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Du Pont Apollo's median module aperture efficiency (6.7%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Du Pont Apollo Module + Third-Party Inverter

Pair Du Pont Apollo modules (95–133W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Du Pont Apollo photovoltaic and inverter hardware listed on the CEC registry.

### How many Du Pont Apollo solar models are verified on the CEC list?

Our CEC archive indexes 4 Du Pont Apollo equipment records (4 module series and 0 inverter models) spanning 95–133W PV. Check local building department permit requirements for Du Pont Apollo before finalizing component orders.

### What should homeowners check before approving Du Pont Apollo equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Du Pont Apollo solar panels compared to CEC averages?

Across listed series, Du Pont Apollo modules show a median aperture efficiency of 6.7% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Du Pont Apollo.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[EcoFlow Inc CEC Solar Catalog (11,443–24,291W AC)](https://epri-peac.com/solar-equipment/brands/ecoflow-inc/) [Energy America LLC CEC Solar Catalog (395–555W PV)](https://epri-peac.com/solar-equipment/brands/energy-america-llc/) [DE SOLAR(S) PTE LTD CEC Solar Catalog (420–585W PV)](https://epri-peac.com/solar-equipment/brands/de-solar-s-pte-ltd/) [Hanersun Technology Co Ltd CEC Solar Catalog (345–430W PV)](https://epri-peac.com/solar-equipment/brands/hanersun-technology-co-ltd/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
