---
title: "Applied Materials Solar Panels & Inverters (8 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/applied-materials/
description: "CEC datasheets for Applied Materials: 114–458W PV, 8 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Applied Materials — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Applied Materials holds 8 verified California Energy Commission (CEC) certifications including 8 module series (114–458W PV). Applied Materials carries 8 module series ranging from 114 W to 458 W STC (median 218 W vs 385 W CEC fleet median; 8.0% median aperture efficiency, cell architecture Thin Film). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Applied Materials

- **PV Module Series** : 8

- **Listed Inverters** : 0

- **Output Range** : 114–458W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Applied Materials Solar Specifications Compare Across the CEC Catalog?

Portfolio capacity, conversion efficiency, and safety recall screening for Applied Materials solar hardware certified under California Energy Commission standards.

Flagship CEC certification records for Applied Materials include Applied Materials Full Size Tandem Junction alongside 8 verified brand entries. Applied Materials carries 8 module series ranging from 114 W to 458 W STC (median 218 W vs 385 W CEC fleet median; 8.0% median aperture efficiency, cell architecture Thin Film). Permitting inspectors cross-reference exact CEC model strings on utility interconnection packets. No active CPSC electrical recalls match Applied Materials in our federal recall archive as of 2026.

## Which Applied Materials PV Module Series Are CEC Certified? (8)

Certified Applied Materials PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Filter Applied Materials Modules

Deduplicated CEC photovoltaic module series for Applied Materials.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-tandem-junction/) | 458.0 | 420.2 | 280.0 | 8.01 | 1 |
| [**Applied Materials Full Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-single-junction-version-10/) | 414.0 | 384.8 | 194.2 | 7.24 | 1 |
| [**Applied Materials 1/2-L Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-2-l-size-tandem-junction/) | 229.0 | 210.1 | 280.0 | 8.01 | 1 |
| [**Applied Materials 1/2-P Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-2-p-size-tandem-junction/) | 229.0 | 210.1 | 137.6 | 8.01 | 1 |
| [**Applied Materials 1/2-L Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-2-l-size-single-junction-version-10/) | 207.0 | 192.4 | 194.2 | 7.24 | 1 |
| [**Applied Materials 1/2-P Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-2-p-size-single-junction-version-10/) | 207.0 | 192.4 | 97.1 | 7.24 | 1 |
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) | 116.0 | 107.9 | 96.2 | 8.11 | 1 |
| [**Applied Materials 1/4 Size Tandem Junction**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-tandem-junction/) | 114.0 | 104.6 | 137.6 | 7.97 | 1 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Applied Materials Solar Hardware?

Evaluate Applied Materials CEC certifications (114–458W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Applied Materials certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Applied Materials's median module aperture efficiency (8.0%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Applied Materials Module + Third-Party Inverter

Pair Applied Materials modules (114–458W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring Applied Materials solar modules or inverters. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

### How many Applied Materials solar models are verified on the CEC list?

Our CEC archive indexes 8 Applied Materials equipment records (8 module series and 0 inverter models) spanning 114–458W PV. Check local building department permit requirements for Applied Materials before finalizing component orders.

### What should homeowners check before approving Applied Materials equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Applied Materials solar panels compared to CEC averages?

Across listed series, Applied Materials modules show a median aperture efficiency of 8.0% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Applied Materials.

## Related Pages

Explore nearby California Energy Commission listed equipment brands and verify NEC 690.7 and 705.12 limits before signing an installation contract.

[Bluesun Solar Energy Tech CoLtd CEC Solar Catalog (270–380W PV)](https://epri-peac.com/solar-equipment/brands/bluesun-solar-energy-tech-coltd/) [DEHUI SOLAR POWER INC CEC Solar Catalog (270–375W PV)](https://epri-peac.com/solar-equipment/brands/dehui-solar-power-inc/) [Afore New Energy Technology (Shanghai) Co Ltd CEC Solar Catalog (4,600–9,592W AC)](https://epri-peac.com/solar-equipment/brands/afore-new-energy-technology-shanghai-co-ltd/) [EG4 Electronics LLC CEC Solar Catalog (7,859–16,153W AC)](https://epri-peac.com/solar-equipment/brands/eg4-electronics-llc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)
