title: "Alps Technology Solar Panels & Inverters (3 CEC Series)"
url: https://epri-peac.com/solar-equipment/brands/alps-technology/
description: "CEC datasheets for Alps Technology: 180–235W PV, 3 module series, 0 inverter models, and NEC limits. Verified CEC solar ratings."
---

CEC Brand Hub

# Alps Technology — CEC Certified Solar Equipment Catalog

Registry: **California Energy Commission (CEC)** Verified: **2026-11-26**

Alps Technology holds 3 verified California Energy Commission (CEC) certifications including 3 module series (180–235W PV). Alps Technology carries 3 module series ranging from 180 W to 235 W STC (median 220 W vs 385 W CEC fleet median; 14.0% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Manufacturer** : Alps Technology

- **PV Module Series** : 3

- **Listed Inverters** : 0

- **Output Range** : 180–235W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Alps Technology Solar Specifications Compare Across the CEC Catalog?

How Alps Technology residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Alps Technology for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Alps Technology carries 3 module series ranging from 180 W to 235 W STC (median 220 W vs 385 W CEC fleet median; 14.0% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). No active CPSC electrical recalls match Alps Technology in our federal recall archive as of 2026.

## Which Alps Technology PV Module Series Are CEC Certified? (3)

Every deduplicated Alps Technology solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Alps Technology Modules

Deduplicated CEC photovoltaic module series for Alps Technology.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Alps Technology ATI-M660-235**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-m660-235/) | 235.0 | 202.5 | 36.72 | 14.6 | 4 |
| [**Alps Technology ATI-M660-220**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-m660-220/) | 220.0 | 189.1 | 36.06 | 13.67 | 1 |
| [**Alps Technology ATI-S572-180**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-s572-180/) | 180.0 | 155.7 | 44.06 | 13.98 | 3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Alps Technology Solar Hardware?

Evaluate Alps Technology CEC certifications (180–235W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Alps Technology certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Constrained roofs: Alps Technology's median module aperture efficiency (14.0%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

### Alps Technology Module + Third-Party Inverter

Pair Alps Technology modules (180–235W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Alps Technology solar equipment. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

### How many Alps Technology solar models are verified on the CEC list?

Our CEC archive indexes 3 Alps Technology equipment records (3 module series and 0 inverter models) spanning 180–235W PV. Check local building department permit requirements for Alps Technology before finalizing component orders.

### What should homeowners check before approving Alps Technology equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Alps Technology solar panels compared to CEC averages?

Across listed series, Alps Technology modules show a median aperture efficiency of 14.0% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Alps Technology.

## Related Pages

Compare Alps Technology against peer solar manufacturers, review CEC datasheet distributions, or open interactive NEC string-voltage and 120% busbar sizing calculators.

[BLUESUN GROUP LIMITED CEC Solar Catalog (565–605W PV)](https://epri-peac.com/solar-equipment/brands/bluesun-group-limited/) [BYD Auto Industry Company Limited CEC Solar Catalog (60,276–501,756W AC)](https://epri-peac.com/solar-equipment/brands/byd-auto-industry-company-limited/) [Zhongshan Ruike New Energy Co Ltd CEC Solar Catalog (75–105W PV)](https://epri-peac.com/solar-equipment/brands/zhongshan-ruike-new-energy-co-ltd/) [DuCal Solar Technology LLC CEC Solar Catalog (270–305W PV)](https://epri-peac.com/solar-equipment/brands/ducal-solar-technology-llc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)