Allesun Industries Inc holds 4 verified California Energy Commission (CEC) certifications including 4 module series (535–585W PV). Allesun Industries Inc carries 4 module series ranging from 535 W to 585 W STC (median 552 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si).

- **Manufacturer** : Allesun Industries Inc

- **PV Module Series** : 4

- **Listed Inverters** : 0

- **Output Range** : 535–585W PV

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Do Allesun Industries Inc Solar Specifications Compare Across the CEC Catalog?

Detailed California Energy Commission portfolio breakdown covering nameplate power spread, cell technology, thermal efficiency, and CPSC recall screening for Allesun Industries Inc.

Allesun Industries Inc participates in the California Energy Commission (CEC) Solar Equipment List with 4 total certified hardware listings. Allesun Industries Inc carries 4 module series ranging from 535 W to 585 W STC (median 552 W vs 385 W CEC fleet median; 20.9% median aperture efficiency, cell architecture Mono-c-Si). No active CPSC electrical recalls match Allesun Industries Inc in our federal recall archive as of 2026.

## Which Allesun Industries Inc PV Module Series Are CEC Certified? (4)

Every deduplicated Allesun Industries Inc solar module series listed below links to its full PTC/STC rating table, cold-weather Voc curve, and roof area calculator.

Filter Allesun Industries Inc Modules

Deduplicated CEC photovoltaic module series for Allesun Industries Inc.

| Module Series | STC (W) | PTC (W) | Voc (V) | Eff (%) | Variants |
|---|---|---|---|---|---|
| [**Allesun Industries Inc Allesun-585-78IIMBG**](https://epri-peac.com/solar-equipment/modules/allesun-industries-inc/allesun-industries-inc-allesun-585-78iimbg/) | 585.0 | 549.9 | 53.73 | 20.97 | 4 |
| [**Allesun Industries Inc Allesun-570-78IIMBG**](https://epri-peac.com/solar-equipment/modules/allesun-industries-inc/allesun-industries-inc-allesun-570-78iimbg/) | 570.0 | 535.5 | 53.3 | 20.43 | 1 |
| [**Allesun Industries Inc AS-535-72IIMB**](https://epri-peac.com/solar-equipment/modules/allesun-industries-inc/allesun-industries-inc-as-535-72iimb/) | 535.0 | 503.2 | 49.35 | 20.9 | 3 |
| [**Allesun Industries Inc Allesun-535-72IIMBG**](https://epri-peac.com/solar-equipment/modules/allesun-industries-inc/allesun-industries-inc-allesun-535-72iimbg/) | 535.0 | 502.9 | 49.34 | 20.9 | 3 |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Allesun Industries Inc Solar Hardware?

Evaluate Allesun Industries Inc CEC certifications (535–585W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

- Allesun Industries Inc certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
- Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

### Allesun Industries Inc Module + Third-Party Inverter

Pair Allesun Industries Inc modules (535–585W PV) with microinverters or string inverters rated above local cold-weather Voc.

### Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Allesun Industries Inc photovoltaic and inverter hardware listed on the CEC registry.

### How many Allesun Industries Inc solar models are verified on the CEC list?

Our CEC archive indexes 4 Allesun Industries Inc equipment records (4 module series and 0 inverter models) spanning 535–585W PV. Check local building department permit requirements for Allesun Industries Inc before finalizing component orders.

### What should homeowners check before approving Allesun Industries Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

### How efficient are Allesun Industries Inc solar panels compared to CEC averages?

Across listed series, Allesun Industries Inc modules show a median aperture efficiency of 20.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Allesun Industries Inc.

## Related Pages

Check peer solar brands, main-panel busbar rules, CEC equipment catalogs, and cold-climate string voltage calculators related to Allesun Industries Inc.

[Alpha ESS Co Ltd CEC Solar Catalog (7,644–9,628W AC)](https://epri-peac.com/solar-equipment/brands/alpha-ess-co-ltd/) [Anji Technology CEC Solar Catalog (180–250W PV)](https://epri-peac.com/solar-equipment/brands/anji-technology/) [Alexus Solar CEC Solar Catalog (405–550W PV)](https://epri-peac.com/solar-equipment/brands/alexus-solar/) [ASTORIOS Holding Inc CEC Solar Catalog (395–555W PV)](https://epri-peac.com/solar-equipment/brands/astorios-holding-inc/) [All CEC Certified Solar Manufacturers](https://epri-peac.com/solar-equipment/brands/) [Check NEC 690.7 Cold-Temp PV String Voc Limit](https://epri-peac.com/tools/pv-string-voc/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Inverters.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

NEC Calculators

Check Sizing Before Buying

Verify cold-weather string Voc under NEC 690.7 and 120% panel busbar limits under NEC 705.12 before selecting equipment.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Solar Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)