U.S. CPSC Public Recall Database

# CPSC Recall #05035: CPSC, Schneider Electric North American Division Announce Recall of AFCIs

Agency: **U.S. CPSC SaferProducts API** Verified: **2026-11-26**

Issued by the U.S. Consumer Product Safety Commission on 2004-11-03 under Notice #05035 (22 years ago, #11 of 21 circuit breaker notices), this recall covers About 700,000 tied to Schneider Electric North American Division with 1 documented hazard note(s) and 1 corrective remedy option(s) detailed below. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Recall Number** : 05035

- **Recall Date** : 2004-11-03

- **Units Affected** : About 700,000

- **Category** : Circuit Breaker · #11 of 21

## What Is the Official CPSC Hazard Summary and Free Homeowner Remedy?

Verify affected About 700,000 models from Schneider Electric North American Division, of Palatine, Ill. against CPSC Notice #05035 (2004-11-03), hazard summary, and free replacement instructions.

The recalled Square D QO® and Homeline® Arc Fault Interrupter circuit breakers are used with 15- and 20-amp branch circuits. They are required to be installed in bedroom circuits in accordance with the 2002 National Electrical Code. The recalled units were manufactured after March 1, 2004, and have a blue test button. The AFCI circuit breakers have one of the following date codes - CN, DN, EN, FN, GN, HN, or JN - stamped in red on the breaker label located just above the wiring terminal.

Affected population spans About 700,000 attributed to Schneider Electric North American Division, of Palatine, Ill.. Reported failure mechanism: An AFCI is an electrical circuit protection device (circuit breaker) that detects electrical arcs from cracked, broken or damaged electrical insulation and shuts off power to the circuit before the arcing leads to a fire. An electronic component failure inside the AFCIs can cause the devices to not detect an electrical arc. Although the AFCIs will function as regular circuit breakers, they may not detect an arc fault, posing a safety risk to consumers. This 2004-11-03 filing represents record #11/21 in the circuit breaker archive; verify serial plates against the scope above. Remedy guidance: Installed AFCIs will be replaced free of charge through electrical contractors. Consumers can return uninstalled AFCIs to the retailers or distributor from whom the unit was purchased for a free replacement unit.

Structured CPSC safety record for Notice #05035.

| Recall Number & ID | 05035 (ID 2810) |
|---|---|
| Date & Category Rank | 2004-11-03 (22 yrs / #11 of 21) |
| Units Impacted | About 700,000 (700,000 parsed units) |
| Importers / Makers | Schneider Electric North American Division, of Palatine, Ill. |
| Hazard Findings (1) | An AFCI is an electrical circuit protection device (circuit breaker) that detects electrical arcs from cracked, broken or damaged electrical insulation and shuts off power to the circuit before the arcing leads to a fire. An electronic component failure inside the AFCIs can cause the devices to not detect an electrical arc. Although the AFCIs will function as regular circuit breakers, they may not detect an arc fault, posing a safety risk to consumers |
| Corrective Remedies (1) | Installed AFCIs will be replaced free of charge through electrical contractors. Consumers can return uninstalled AFCIs to the retailers or distributor from whom the unit was purchased for a free replacement unit |
| Primary Agency Filing | [Official CPSC Record #05035](https://www.cpsc.gov/Recalls/2005/CPSC-Schneider-Electric-North-American-Division-Announce-Recall-of-AFCIs) |

## Which Related Circuit Breaker Recall Notices Should Inspectors Check?

Compare CPSC Notice #05035 (2004-11-03) against peer circuit breaker filings affecting similar equipment classes and date ranges.

- [**#26194 (2026-01-15)** — HEZI Brand Power Strips Recalled Due to Risk of Serious Injury or Death from Electrocution; Sold by HEZI HOME](https://epri-peac.com/recalls/26194-hezi-brand-power-strips-recalled-due-to-risk-of-serious/)
- [**#16769 (2016-08-30)** — United Copper Recalls Metal Clad Cables Due to Fire and Shock Hazards (Recall Alert)](https://epri-peac.com/recalls/16769-united-copper-recalls-metal-clad-cables-due-to-fire-and/)
- [**#16711 (2015-12-09)** — Basler Electric Recalls Transformers Due to Fire, Shock Hazards (Recall Alert)](https://epri-peac.com/recalls/16711-basler-electric-recalls-transformers-due-to-fire-shock/)
- [**#15050 (2014-12-18)** — Schneider Electric Recalls PowerPact J-Frame Circuit Breakers Due to Fire, Burn, Electrical Shock Hazards](https://epri-peac.com/recalls/15050-schneider-electric-recalls-powerpact-j-frame-circuit-br/)

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers below come directly from official U.S. CPSC SaferProducts recall notices, manufacturer safety bulletins, and National Electrical Code rules.

### How can owners check CPSC Recall #05035 on Schneider Electric North American Division circuit breaker gear?

Shut off branch power safely, match nameplate dates on Schneider Electric North American Division units against CPSC Notice #05035 (2004-11-03), and stop running CPSC, Schneider Electric North American Division Announce until remediated.

### What defect and free remedy apply to CPSC, Schneider Electric North American Division Announce?

CPSC records for Schneider Electric North American Division cite An AFCI is an electrical circuit protection device that; the authorized consumer remedy provides Installed AFCIs will be replaced free of charge through at zero charge.

### Should a licensed electrician inspect Schneider Electric North American Division hardwired circuit breaker units?

Yes—remediation requiring panelboard covers, breaker replacements, or service disconnects should be completed and torqued under NEC 110.14(D) by a licensed electrician. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting 05035 Cpsc Schneider Electric North American Division Announ.

## Related Pages

Explore related circuit breaker compatibility guides, emergency electrical safety checklists, CEC solar equipment specs, and licensed electrician directories.

[Square D QO & Homeline Matrix](https://epri-peac.com/breakers/square-d-homeline/) [Browse All CPSC Electrical & Solar Recalls](https://epri-peac.com/recalls/) [0-to-15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/) [Verify State-Licensed Electricians](https://epri-peac.com/pros/)

## Sources

1. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Matched Panel Architecture

Check CPSC notice links alongside legacy panel safety advisories and UL Classified replacement breaker matrices.
[Square D QO & Homeline Matrix](https://epri-peac.com/breakers/square-d-homeline/)