title: "Tesla Code PW-AC-OVERVOLT: AC Inverter Overvoltage Shutdown"
url: https://epri-peac.com/error-codes/tesla-pw-ac-overvolt-ac-inverter-overvoltage-shutdown/
description: "Troubleshoot Tesla PW-AC-OVERVOLT (AC Inverter Overvoltage Shutdown) on Tesla Powerwall 2 / 3: verified trigger cause, safe homeowner check, licensed repair."
---

Tesla | IEEE 1547 / NEC 310.16

# Tesla Error Code PW-AC-OVERVOLT — AC Inverter Overvoltage Shutdown

Manufacturer: **Tesla** System: **Tesla Powerwall 2 / 3** Code Reference: **IEEE 1547 / NEC 310.16** Verified: **2026-11-26**

When Tesla Powerwall 2 / 3 displays Tesla code PW-AC-OVERVOLT (AC Inverter Overvoltage Shutdown), equipment controls have detected an operating fault linked to IEEE 1547 / NEC 310.16. Start with safe visual verification—Check if error aligns with midday neighborhood solar export peaks—before scheduling a qualified technician for licensed IEEE 1547 / NEC 310.16 diagnostics.

- **OEM Platform** : Tesla (Tesla Powerwall 2 / 3)

- **Fault Code** : PW-AC-OVERVOLT

- **Fault Summary** : AC Inverter Overvoltage Shutdown

- **Code Reference** : IEEE 1547 / NEC 310.16

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## What Triggers Tesla PW-AC-OVERVOLT — AC Inverter Overvoltage Shutdown?

How Tesla Powerwall 2 / 3 protection firmware detects AC Inverter Overvoltage Shutdown and isolates AC or DC power flow when logging Tesla fault PW-AC-OVERVOLT.

Local transformer voltage exceeded ~264V AC while Powerwall attempted export, forcing protective standby.

## What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Step-by-step safety boundary separating cover-closed homeowner monitoring observations from certified IEEE 1547 / NEC 310.16 electrical diagnostics and torque tests.

Safe Homeowner Check (Zero Cover Removal)

### Visual & App Verification

Check if error aligns with midday neighborhood solar export peaks.

Licensed Service Scope — IEEE 1547 / NEC 310.16

### Technician Diagnostic Protocol

Measure utility L1-L2 voltage and verify wire gauge from Powerwall breaker to Gateway (NEC 310.16 / 210.19).

## Which Related Tesla Fault Codes Should You Cross-Check?

Compare Tesla PW-AC-OVERVOLT against sibling manufacturer diagnostic codes such as PW-ISLAND — Grid Outage — Off-Grid Backup Active to rule out upstream utility or sensor issues.

[PW-ISLAND — Grid Outage — Off-Grid Backup Active](https://epri-peac.com/error-codes/tesla-pw-island-grid-outage/) [GW-RELAY — Gateway Grid Contactor / Relay Fault](https://epri-peac.com/error-codes/tesla-gw-relay-gateway-grid-contactor-relay-fault/) [PW-FREQ-CURTAIL — Over-Frequency Solar Curtailment (Off-Grid)](https://epri-peac.com/error-codes/tesla-pw-freq-curtail-over-frequency-solar-curtailment-off-grid/) [PW-STORM-WATCH — Storm Watch — Pre-Charging to 100%](https://epri-peac.com/error-codes/tesla-pw-storm-watch-storm-watch/) [PW-CT-REV — Site / Solar CT Polarity Reversed](https://epri-peac.com/error-codes/tesla-pw-ct-rev-site-solar-ct-polarity-reversed/)

What to Check & Best-Fit Scenarios

## What Are the Safety Limits When Resolving Tesla PW-AC-OVERVOLT (AC Inverter Overvoltage Shutdown)?

Follow live-voltage exclusion zones and lockout rules for Tesla Powerwall 2 / 3 equipment under IEEE 1547 / NEC 310.16 before attempting restarts or breaker resets.

- Do not open wireways or DC junction boxes on Tesla Powerwall 2 / 3: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
- Repeatedly clearing Tesla PW-AC-OVERVOLT (AC Inverter Overvoltage Shutdown) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

### Homeowner Observation (PW-AC-OVERVOLT)

Stick strictly to non-invasive app and breaker status checks for Tesla PW-AC-OVERVOLT without opening electrical covers.

### Licensed Technician Scope (IEEE 1547 / NEC 310.16)

Engage a certified Tesla technician to perform IEEE 1547 / NEC 310.16 resistance, pressure, or torque testing on Tesla Powerwall 2 / 3.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for Tesla PW-AC-OVERVOLT (AC Inverter Overvoltage Shutdown) backed by Tesla Powerwall 2 / 3 OEM manuals and NFPA 70 clearances.

### Is Tesla fault code PW-AC-OVERVOLT safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Check if error aligns with midday neighborhood solar export peaks. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under IEEE 1547 / NEC 310.16.

### What causes Tesla PW-AC-OVERVOLT (AC Inverter Overvoltage Shutdown) on Tesla Powerwall 2 / 3?

Local transformer voltage exceeded ~264V AC while Powerwall attempted export, forcing protective standby. Consult published equipment installation sheets alongside Tesla Pw Ac Overvolt Ac Inverter Overvoltage Shutdown tables before disconnecting power.

### How does a licensed electrician resolve Tesla PW-AC-OVERVOLT?

Under IEEE 1547 / NEC 310.16, a qualified technician resolves Tesla PW-AC-OVERVOLT using published OEM protocol: Measure utility L1-L2 voltage and verify wire gauge from Powerwall breaker to Gateway (NEC 310.16 / 210.19).

## Related Pages

Check related Tesla diagnostic alerts, emergency electrical triage steps, CEC solar equipment specs, and licensed contractor listings. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

[Tesla PW-ISLAND: Grid Outage — Off-Grid Backup Active](https://epri-peac.com/error-codes/tesla-pw-island-grid-outage/) [Tesla GW-RELAY: Gateway Grid Contactor / Relay Fault](https://epri-peac.com/error-codes/tesla-gw-relay-gateway-grid-contactor-relay-fault/) [All 64 Solar & Generator Fault Codes](https://epri-peac.com/error-codes/) [0–15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/)

## Sources

1. [OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy)](https://support.enphase.com/s/article/System-Events-and-Error-Messages) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Safety First

Urgent Hazard Signs

If you smell burnt plastic, hear panel buzzing, or see water intrusion inside an enclosure, shut down the main disconnect safely or call emergency triage.
[Electrical Emergency Triage](https://epri-peac.com/emergency/) [Find Licensed Electricians](https://epri-peac.com/pros/)