title: "SolarEdge Code 1x-NO-GRID: Error 1x — No AC Grid Voltage"
url: https://epri-peac.com/error-codes/solaredge-1x-no-grid-error-1x/
description: "Troubleshoot SolarEdge 1x-NO-GRID (Error 1x — No AC Grid Voltage Detected) on SolarEdge HD-Wave / Energy Hub: verified trigger cause, safe homeowner check."
---

SolarEdge | NEC 705.12 / 690.13

# SolarEdge Error Code 1x-NO-GRID — Error 1x — No AC Grid Voltage Detected

Manufacturer: **SolarEdge** System: **SolarEdge HD-Wave / Energy Hub** Code Reference: **NEC 705.12 / 690.13** Verified: **2026-11-26**

SolarEdge code 1x-NO-GRID identifies Error 1x — No AC Grid Voltage Detected in residential SolarEdge HD-Wave / Energy Hub equipment. Follow non-invasive checks (Inspect the dedicated solar backfeed breaker in your main panel and confirm the exterior utility AC disconnect handle is UP/ON) and consult a qualified technician referencing NEC 705.12 / 690.13 if the warning does not self-clear.

- **OEM Platform** : SolarEdge (SolarEdge HD-Wave / Energy Hub)

- **Fault Code** : 1x-NO-GRID

- **Fault Summary** : Error 1x — No AC Grid Voltage Detected

- **Code Reference** : NEC 705.12 / 690.13

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## What Triggers SolarEdge 1x-NO-GRID — Error 1x — No AC Grid Voltage Detected?

Field protection logic explaining why SolarEdge SolarEdge HD-Wave / Energy Hub units halt or derate output with diagnostic alert 1x-NO-GRID (Error 1x — No AC Grid Voltage Detected).

Inverter sees 0V on AC output terminals due to a tripped main solar breaker, open AC disconnect, or utility blackout.

## What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Homeowner-safe cover-closed verification versus licensed NEC 705.12 / 690.13 multimeter, pressure, and conductor torque inspection for SolarEdge 1x-NO-GRID. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Safe Homeowner Check (Zero Cover Removal)

### Visual & App Verification

Inspect the dedicated solar backfeed breaker in your main panel and confirm the exterior utility AC disconnect handle is UP/ON.

Licensed Service Scope — NEC 705.12 / 690.13

### Technician Diagnostic Protocol

Test L1-L2 (240V) and L1/L2-N (120V) at the inverter AC terminal block and check breaker stab contact condition.

## Which Related SolarEdge Fault Codes Should You Cross-Check?

Review related SolarEdge system diagnostic alerts—starting with 18xB7 — Error 18xB7 — Hardware / Internal Inverter Fault—whenever multiple protection faults log together in monitoring portals.

[18xB7 — Error 18xB7 — Hardware / Internal Inverter Fault](https://epri-peac.com/error-codes/solaredge-18xb7-error-18xb7/) [3x6E — Error 3x6E — DC Isolation Fault (Low Riso)](https://epri-peac.com/error-codes/solaredge-3x6e-error-3x6e/) [18x89 — Error 18x89 — DC Arc-Fault Detected (AFCI)](https://epri-peac.com/error-codes/solaredge-18x89-error-18x89/) [2x-GRID-V — Error 2x — AC Grid Over/Undervoltage](https://epri-peac.com/error-codes/solaredge-2x-grid-v-error-2x/) [8x-GRID-F — Error 8x — AC Grid Frequency Out of Bounds](https://epri-peac.com/error-codes/solaredge-8x-grid-f-error-8x/)

What to Check & Best-Fit Scenarios

## What Are the Safety Limits When Resolving SolarEdge 1x-NO-GRID (Error 1x — No AC Grid Voltage Detected)?

Follow live-voltage exclusion zones and lockout rules for SolarEdge HD-Wave / Energy Hub equipment under NEC 705.12 / 690.13 before attempting restarts or breaker resets.

- Do not open wireways or DC junction boxes on SolarEdge HD-Wave / Energy Hub: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
- Repeatedly clearing SolarEdge 1x-NO-GRID (Error 1x — No AC Grid Voltage Detected) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

### Homeowner Observation (1x-NO-GRID)

Stick strictly to non-invasive app and breaker status checks for SolarEdge 1x-NO-GRID without opening electrical covers.

### Licensed Technician Scope (NEC 705.12 / 690.13)

Engage a certified SolarEdge technician to perform NEC 705.12 / 690.13 resistance, pressure, or torque testing on SolarEdge HD-Wave / Energy Hub.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for SolarEdge 1x-NO-GRID (Error 1x — No AC Grid Voltage Detected) backed by SolarEdge HD-Wave / Energy Hub OEM manuals and NFPA 70 clearances.

### Is SolarEdge fault code 1x-NO-GRID safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Inspect the dedicated solar backfeed breaker in your main panel and confirm the exterior utility AC disconnect handle is UP/ON. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under NEC 705.12 / 690.13.

### What causes SolarEdge 1x-NO-GRID (Error 1x — No AC Grid Voltage Detected) on SolarEdge HD-Wave / Energy Hub?

Inverter sees 0V on AC output terminals due to a tripped main solar breaker, open AC disconnect, or utility blackout. Consult published equipment installation sheets alongside Solaredge 1X No Grid Error 1X tables before disconnecting power.

### How does a licensed electrician resolve SolarEdge 1x-NO-GRID?

Under NEC 705.12 / 690.13, a qualified technician resolves SolarEdge 1x-NO-GRID using published OEM protocol: Test L1-L2 (240V) and L1/L2-N (120V) at the inverter AC terminal block and check breaker stab contact condition.

## Related Pages

Check related SolarEdge diagnostic alerts, emergency electrical triage steps, CEC solar equipment specs, and licensed contractor listings. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

[SolarEdge 18xB7: Error 18xB7 — Hardware / Internal Inverter Fault](https://epri-peac.com/error-codes/solaredge-18xb7-error-18xb7/) [SolarEdge 3x6E: Error 3x6E — DC Isolation Fault (Low Riso)](https://epri-peac.com/error-codes/solaredge-3x6e-error-3x6e/) [All 64 Solar & Generator Fault Codes](https://epri-peac.com/error-codes/) [0–15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/)

## Sources

1. [OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy)](https://support.enphase.com/s/article/System-Events-and-Error-Messages) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Safety First

Urgent Hazard Signs

If you smell burnt plastic, hear panel buzzing, or see water intrusion inside an enclosure, shut down the main disconnect safely or call emergency triage.
[Electrical Emergency Triage](https://epri-peac.com/emergency/) [Find Licensed Electricians](https://epri-peac.com/pros/)