title: "SMA Code EVT-6402: Event 6402 — Temperature Power Derating"
url: https://epri-peac.com/error-codes/sma-evt-6402-event-6402/
description: "Troubleshoot SMA EVT-6402 (Event 6402 — Temperature Power Derating) on SMA Sunny Boy US-40 / US-41: verified trigger cause, safe homeowner check, licensed."
---

SMA | NEC 110.3(B)

# SMA Error Code EVT-6402 — Event 6402 — Temperature Power Derating

Manufacturer: **SMA** System: **SMA Sunny Boy US-40 / US-41** Code Reference: **NEC 110.3(B)** Verified: **2026-11-26**

SMA code EVT-6402 identifies Event 6402 — Temperature Power Derating in residential SMA Sunny Boy US-40 / US-41 equipment. Follow non-invasive checks (Verify airflow around the blue/red SMA casing and clear wasp nests or dust from rear heatsink channels) and consult a qualified technician referencing NEC 110.3(B) if the warning does not self-clear.

- **OEM Platform** : SMA (SMA Sunny Boy US-40 / US-41)

- **Fault Code** : EVT-6402

- **Fault Summary** : Event 6402 — Temperature Power Derating

- **Code Reference** : NEC 110.3(B)

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## What Triggers SMA EVT-6402 — Event 6402 — Temperature Power Derating?

Field protection logic explaining why SMA SMA Sunny Boy US-40 / US-41 units halt or derate output with diagnostic alert EVT-6402 (Event 6402 — Temperature Power Derating).

Inverter reduced AC power above ~113 F ambient to protect internal power electronics.

## What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Homeowner-safe cover-closed verification versus licensed NEC 110.3(B) multimeter, pressure, and conductor torque inspection for SMA EVT-6402. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Safe Homeowner Check (Zero Cover Removal)

### Visual & App Verification

Verify airflow around the blue/red SMA casing and clear wasp nests or dust from rear heatsink channels.

Licensed Service Scope — NEC 110.3(B)

### Technician Diagnostic Protocol

Confirm DC-to-AC oversizing ratio and check mounting orientation/sun-shade exposure.

## Which Related SMA Fault Codes Should You Cross-Check?

Review related SMA system diagnostic alerts—starting with EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded—whenever multiple protection faults log together in monitoring portals.

[EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [EVT-201 — Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [EVT-3501 — Event 3501 — Insulation Resistance (Riso) Low](https://epri-peac.com/error-codes/sma-evt-3501-event-3501/) [EVT-4301 — Event 4301 — AFCI Arc-Fault Interruption](https://epri-peac.com/error-codes/sma-evt-4301-event-4301/) [EVT-7001 — Event 7001 — Internal Self-Test / Relay Check](https://epri-peac.com/error-codes/sma-evt-7001-event-7001/)

What to Check & Best-Fit Scenarios

## What Are the Safety Limits When Resolving SMA EVT-6402 (Event 6402 — Temperature Power Derating)?

Follow live-voltage exclusion zones and lockout rules for SMA Sunny Boy US-40 / US-41 equipment under NEC 110.3(B) before attempting restarts or breaker resets.

- Do not open wireways or DC junction boxes on SMA Sunny Boy US-40 / US-41: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
- Repeatedly clearing SMA EVT-6402 (Event 6402 — Temperature Power Derating) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

### Homeowner Observation (EVT-6402)

Stick strictly to non-invasive app and breaker status checks for SMA EVT-6402 without opening electrical covers.

### Licensed Technician Scope (NEC 110.3 — B)

Engage a certified SMA technician to perform NEC 110.3(B) resistance, pressure, or torque testing on SMA Sunny Boy US-40 / US-41.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for SMA EVT-6402 (Event 6402 — Temperature Power Derating) backed by SMA Sunny Boy US-40 / US-41 OEM manuals and NFPA 70 clearances.

### Is SMA fault code EVT-6402 safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Verify airflow around the blue/red SMA casing and clear wasp nests or dust from rear heatsink channels. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under NEC 110.3(B).

### What causes SMA EVT-6402 (Event 6402 — Temperature Power Derating) on SMA Sunny Boy US-40 / US-41?

Inverter reduced AC power above ~113 F ambient to protect internal power electronics. Consult published equipment installation sheets alongside Sma Evt 6402 Event 6402 tables before disconnecting power.

### How does a licensed electrician resolve SMA EVT-6402?

Under NEC 110.3(B), a qualified technician resolves SMA EVT-6402 using published OEM protocol: Confirm DC-to-AC oversizing ratio and check mounting orientation/sun-shade exposure. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Sma Evt 6402 Event 6402.

## Related Pages

Check related SMA diagnostic alerts, emergency electrical triage steps, CEC solar equipment specs, and licensed contractor listings. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

[SMA EVT-101: Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [SMA EVT-201: Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [All 64 Solar & Generator Fault Codes](https://epri-peac.com/error-codes/) [0–15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/)

## Sources

1. [OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy)](https://support.enphase.com/s/article/System-Events-and-Error-Messages) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Safety First

Urgent Hazard Signs

If you smell burnt plastic, hear panel buzzing, or see water intrusion inside an enclosure, shut down the main disconnect safely or call emergency triage.
[Electrical Emergency Triage](https://epri-peac.com/emergency/) [Find Licensed Electricians](https://epri-peac.com/pros/)