title: "SMA Code EVT-4101: Event 4101 — Secure Power Supply — SPS"
url: https://epri-peac.com/error-codes/sma-evt-4101-event-4101/
description: "Troubleshoot SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) on SMA Sunny Boy US-40 / US-41: verified trigger cause, safe homeowner check."
---

SMA | NEC 705 / 210.21

# SMA Error Code EVT-4101 — Event 4101 — Secure Power Supply (SPS) Active

Manufacturer: **SMA** System: **SMA Sunny Boy US-40 / US-41** Code Reference: **NEC 705 / 210.21** Verified: **2026-11-26**

When SMA Sunny Boy US-40 / US-41 displays SMA code EVT-4101 (Event 4101 — Secure Power Supply — SPS Active), equipment controls have detected an operating fault linked to NEC 705 / 210.21. Start with safe visual verification—Keep total plugged-in SPS devices under 2,000W (16.6A @ 120V) and flip SPS switch OFF once utility power returns—before scheduling a qualified technician for licensed NEC 705 / 210.21 diagnostics.

- **OEM Platform** : SMA (SMA Sunny Boy US-40 / US-41)

- **Fault Code** : EVT-4101

- **Fault Summary** : Event 4101 — Secure Power Supply (SPS) Active

- **Code Reference** : NEC 705 / 210.21

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## What Triggers SMA EVT-4101 — Event 4101 — Secure Power Supply (SPS) Active?

How SMA Sunny Boy US-40 / US-41 protection firmware detects Event 4101 — Secure Power Supply — SPS Active and isolates AC or DC power flow when logging SMA fault EVT-4101.

Daytime emergency 2,000W 120V outlet mode engaged via wall switch during a grid outage.

## What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Step-by-step safety boundary separating cover-closed homeowner monitoring observations from certified NEC 705 / 210.21 electrical diagnostics and torque tests.

Safe Homeowner Check (Zero Cover Removal)

### Visual & App Verification

Keep total plugged-in SPS devices under 2,000W (16.6A @ 120V) and flip SPS switch OFF once utility power returns.

Licensed Service Scope — NEC 705 / 210.21

### Technician Diagnostic Protocol

Verify dedicated 20A SPS duplex outlet wiring per SMA US-40/41 installation instructions.

## Which Related SMA Fault Codes Should You Cross-Check?

Compare SMA EVT-4101 against sibling manufacturer diagnostic codes such as EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded to rule out upstream utility or sensor issues.

[EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [EVT-201 — Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [EVT-3501 — Event 3501 — Insulation Resistance (Riso) Low](https://epri-peac.com/error-codes/sma-evt-3501-event-3501/) [EVT-4301 — Event 4301 — AFCI Arc-Fault Interruption](https://epri-peac.com/error-codes/sma-evt-4301-event-4301/) [EVT-6402 — Event 6402 — Temperature Power Derating](https://epri-peac.com/error-codes/sma-evt-6402-event-6402/)

What to Check & Best-Fit Scenarios

## What Are the Safety Limits When Resolving SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active)?

Follow live-voltage exclusion zones and lockout rules for SMA Sunny Boy US-40 / US-41 equipment under NEC 705 / 210.21 before attempting restarts or breaker resets.

- Do not open wireways or DC junction boxes on SMA Sunny Boy US-40 / US-41: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
- Repeatedly clearing SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

### Homeowner Observation (EVT-4101)

Stick strictly to non-invasive app and breaker status checks for SMA EVT-4101 without opening electrical covers.

### Licensed Technician Scope (NEC 705 / 210.21)

Engage a certified SMA technician to perform NEC 705 / 210.21 resistance, pressure, or torque testing on SMA Sunny Boy US-40 / US-41.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) backed by SMA Sunny Boy US-40 / US-41 OEM manuals and NFPA 70 clearances.

### Is SMA fault code EVT-4101 safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Keep total plugged-in SPS devices under 2,000W (16.6A @ 120V) and flip SPS switch OFF once utility power returns. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under NEC 705 / 210.21.

### What causes SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) on SMA Sunny Boy US-40 / US-41?

Daytime emergency 2,000W 120V outlet mode engaged via wall switch during a grid outage. Consult published equipment installation sheets alongside Sma Evt 4101 Event 4101 tables before disconnecting power.

### How does a licensed electrician resolve SMA EVT-4101?

Under NEC 705 / 210.21, a qualified technician resolves SMA EVT-4101 using published OEM protocol: Verify dedicated 20A SPS duplex outlet wiring per SMA US-40/41 installation instructions.

## Related Pages

Check related SMA diagnostic alerts, emergency electrical triage steps, CEC solar equipment specs, and licensed contractor listings. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

[SMA EVT-101: Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [SMA EVT-201: Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [All 64 Solar & Generator Fault Codes](https://epri-peac.com/error-codes/) [0–15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/)

## Sources

1. [OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy)](https://support.enphase.com/s/article/System-Events-and-Error-Messages) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Safety First

Urgent Hazard Signs

If you smell burnt plastic, hear panel buzzing, or see water intrusion inside an enclosure, shut down the main disconnect safely or call emergency triage.
[Electrical Emergency Triage](https://epri-peac.com/emergency/) [Find Licensed Electricians](https://epri-peac.com/pros/)