title: "SMA Code EVT-3501: Event 3501 — Insulation Resistance — Riso"
url: https://epri-peac.com/error-codes/sma-evt-3501-event-3501/
description: "Troubleshoot SMA EVT-3501 (Event 3501 — Insulation Resistance — Riso Low) on SMA Sunny Boy US-40 / US-41: verified trigger cause, safe homeowner check."
---

SMA | NEC 690.41

# SMA Error Code EVT-3501 — Event 3501 — Insulation Resistance (Riso) Low

Manufacturer: **SMA** System: **SMA Sunny Boy US-40 / US-41** Code Reference: **NEC 690.41** Verified: **2026-11-26**

When SMA Sunny Boy US-40 / US-41 displays SMA code EVT-3501 (Event 3501 — Insulation Resistance — Riso Low), equipment controls have detected an operating fault linked to NEC 690.41. Start with safe visual verification—Turn the integrated DC rotary switch to OFF (0) and avoid touching wet PV conduit—before scheduling a qualified technician for licensed NEC 690.41 diagnostics.

- **OEM Platform** : SMA (SMA Sunny Boy US-40 / US-41)

- **Fault Code** : EVT-3501

- **Fault Summary** : Event 3501 — Insulation Resistance (Riso) Low

- **Code Reference** : NEC 690.41

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## What Triggers SMA EVT-3501 — Event 3501 — Insulation Resistance (Riso) Low?

How SMA Sunny Boy US-40 / US-41 protection firmware detects Event 3501 — Insulation Resistance — Riso Low and isolates AC or DC power flow when logging SMA fault EVT-3501.

Inverter measured low DC-to-ground insulation resistance before morning grid connect.

## What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Step-by-step safety boundary separating cover-closed homeowner monitoring observations from certified NEC 690.41 electrical diagnostics and torque tests. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Safe Homeowner Check (Zero Cover Removal)

### Visual & App Verification

Turn the integrated DC rotary switch to OFF (0) and avoid touching wet PV conduit.

Licensed Service Scope — NEC 690.41

### Technician Diagnostic Protocol

Test individual MPPT strings (A/B/C) with a megohmmeter per NEC 690.41 to isolate damaged PV home runs.

## Which Related SMA Fault Codes Should You Cross-Check?

Compare SMA EVT-3501 against sibling manufacturer diagnostic codes such as EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded to rule out upstream utility or sensor issues.

[EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [EVT-201 — Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [EVT-4301 — Event 4301 — AFCI Arc-Fault Interruption](https://epri-peac.com/error-codes/sma-evt-4301-event-4301/) [EVT-6402 — Event 6402 — Temperature Power Derating](https://epri-peac.com/error-codes/sma-evt-6402-event-6402/) [EVT-7001 — Event 7001 — Internal Self-Test / Relay Check](https://epri-peac.com/error-codes/sma-evt-7001-event-7001/)

What to Check & Best-Fit Scenarios

## What Are the Safety Limits When Resolving SMA EVT-3501 (Event 3501 — Insulation Resistance — Riso Low)?

Follow live-voltage exclusion zones and lockout rules for SMA Sunny Boy US-40 / US-41 equipment under NEC 690.41 before attempting restarts or breaker resets.

- Do not open wireways or DC junction boxes on SMA Sunny Boy US-40 / US-41: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
- Repeatedly clearing SMA EVT-3501 (Event 3501 — Insulation Resistance — Riso Low) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

### Homeowner Observation (EVT-3501)

Stick strictly to non-invasive app and breaker status checks for SMA EVT-3501 without opening electrical covers.

### Licensed Technician Scope (NEC 690.41)

Engage a certified SMA technician to perform NEC 690.41 resistance, pressure, or torque testing on SMA Sunny Boy US-40 / US-41.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for SMA EVT-3501 (Event 3501 — Insulation Resistance — Riso Low) backed by SMA Sunny Boy US-40 / US-41 OEM manuals and NFPA 70 clearances.

### Is SMA fault code EVT-3501 safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Turn the integrated DC rotary switch to OFF (0) and avoid touching wet PV conduit. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under NEC 690.41.

### What causes SMA EVT-3501 (Event 3501 — Insulation Resistance — Riso Low) on SMA Sunny Boy US-40 / US-41?

Inverter measured low DC-to-ground insulation resistance before morning grid connect. Consult published equipment installation sheets alongside Sma Evt 3501 Event 3501 tables before disconnecting power.

### How does a licensed electrician resolve SMA EVT-3501?

Under NEC 690.41, a qualified technician resolves SMA EVT-3501 using published OEM protocol: Test individual MPPT strings (A/B/C) with a megohmmeter per NEC 690.41 to isolate damaged PV home runs.

## Related Pages

Check related SMA diagnostic alerts, emergency electrical triage steps, CEC solar equipment specs, and licensed contractor listings. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

[SMA EVT-101: Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [SMA EVT-201: Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [All 64 Solar & Generator Fault Codes](https://epri-peac.com/error-codes/) [0–15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/)

## Sources

1. [OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy)](https://support.enphase.com/s/article/System-Events-and-Error-Messages) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Safety First

Urgent Hazard Signs

If you smell burnt plastic, hear panel buzzing, or see water intrusion inside an enclosure, shut down the main disconnect safely or call emergency triage.
[Electrical Emergency Triage](https://epri-peac.com/emergency/) [Find Licensed Electricians](https://epri-peac.com/pros/)