title: "SMA Code EVT-302: Event 302 — Grid Disconnection —"
url: https://epri-peac.com/error-codes/sma-evt-302-event-302/
description: "Troubleshoot SMA EVT-302 (Event 302 — Grid Disconnection — Anti-Islanding) on SMA Sunny Boy US-40 / US-41: verified trigger cause, safe homeowner check."
---

SMA | IEEE 1547 / NEC 705.12

# SMA Error Code EVT-302 — Event 302 — Grid Disconnection (Anti-Islanding)

Manufacturer: **SMA** System: **SMA Sunny Boy US-40 / US-41** Code Reference: **IEEE 1547 / NEC 705.12** Verified: **2026-11-26**

SMA code EVT-302 identifies Event 302 — Grid Disconnection — Anti-Islanding in residential SMA Sunny Boy US-40 / US-41 equipment. Follow non-invasive checks (Check main utility service status and solar backfeed breaker position in the main panel) and consult a qualified technician referencing IEEE 1547 / NEC 705.12 if the warning does not self-clear.

- **OEM Platform** : SMA (SMA Sunny Boy US-40 / US-41)

- **Fault Code** : EVT-302

- **Fault Summary** : Event 302 — Grid Disconnection (Anti-Islanding)

- **Code Reference** : IEEE 1547 / NEC 705.12

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## What Triggers SMA EVT-302 — Event 302 — Grid Disconnection (Anti-Islanding)?

Field protection logic explaining why SMA SMA Sunny Boy US-40 / US-41 units halt or derate output with diagnostic alert EVT-302 (Event 302 — Grid Disconnection — Anti-Islanding).

Inverter opened AC relays because grid voltage/phase vanished.

## What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Homeowner-safe cover-closed verification versus licensed IEEE 1547 / NEC 705.12 multimeter, pressure, and conductor torque inspection for SMA EVT-302.

Safe Homeowner Check (Zero Cover Removal)

### Visual & App Verification

Check main utility service status and solar backfeed breaker position in the main panel.

Licensed Service Scope — IEEE 1547 / NEC 705.12

### Technician Diagnostic Protocol

Inspect AC junction terminations and test 240V L1-L2 presence at the inverter AC terminal block.

## Which Related SMA Fault Codes Should You Cross-Check?

Review related SMA system diagnostic alerts—starting with EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded—whenever multiple protection faults log together in monitoring portals.

[EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [EVT-201 — Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [EVT-3501 — Event 3501 — Insulation Resistance (Riso) Low](https://epri-peac.com/error-codes/sma-evt-3501-event-3501/) [EVT-4301 — Event 4301 — AFCI Arc-Fault Interruption](https://epri-peac.com/error-codes/sma-evt-4301-event-4301/) [EVT-6402 — Event 6402 — Temperature Power Derating](https://epri-peac.com/error-codes/sma-evt-6402-event-6402/)

What to Check & Best-Fit Scenarios

## What Are the Safety Limits When Resolving SMA EVT-302 (Event 302 — Grid Disconnection — Anti-Islanding)?

Follow live-voltage exclusion zones and lockout rules for SMA Sunny Boy US-40 / US-41 equipment under IEEE 1547 / NEC 705.12 before attempting restarts or breaker resets.

- Do not open wireways or DC junction boxes on SMA Sunny Boy US-40 / US-41: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
- Repeatedly clearing SMA EVT-302 (Event 302 — Grid Disconnection — Anti-Islanding) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

### Homeowner Observation (EVT-302)

Stick strictly to non-invasive app and breaker status checks for SMA EVT-302 without opening electrical covers.

### Licensed Technician Scope (IEEE 1547 / NEC 705.12)

Engage a certified SMA technician to perform IEEE 1547 / NEC 705.12 resistance, pressure, or torque testing on SMA Sunny Boy US-40 / US-41.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for SMA EVT-302 (Event 302 — Grid Disconnection — Anti-Islanding) backed by SMA Sunny Boy US-40 / US-41 OEM manuals and NFPA 70 clearances.

### Is SMA fault code EVT-302 safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Check main utility service status and solar backfeed breaker position in the main panel. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under IEEE 1547 / NEC 705.12.

### What causes SMA EVT-302 (Event 302 — Grid Disconnection — Anti-Islanding) on SMA Sunny Boy US-40 / US-41?

Inverter opened AC relays because grid voltage/phase vanished. Consult published equipment installation sheets alongside Sma Evt 302 Event 302 tables before disconnecting power.

### How does a licensed electrician resolve SMA EVT-302?

Under IEEE 1547 / NEC 705.12, a qualified technician resolves SMA EVT-302 using published OEM protocol: Inspect AC junction terminations and test 240V L1-L2 presence at the inverter AC terminal block.

## Related Pages

Check related SMA diagnostic alerts, emergency electrical triage steps, CEC solar equipment specs, and licensed contractor listings. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

[SMA EVT-101: Event 101 — Grid Voltage Upper Limit Exceeded](https://epri-peac.com/error-codes/sma-evt-101-event-101/) [SMA EVT-201: Event 201 — Grid Frequency Disturbance](https://epri-peac.com/error-codes/sma-evt-201-event-201/) [All 64 Solar & Generator Fault Codes](https://epri-peac.com/error-codes/) [0–15 Minute Electrical Emergency Triage](https://epri-peac.com/emergency/)

## Sources

1. [OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy)](https://support.enphase.com/s/article/System-Events-and-Error-Messages) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Safety First

Urgent Hazard Signs

If you smell burnt plastic, hear panel buzzing, or see water intrusion inside an enclosure, shut down the main disconnect safely or call emergency triage.
[Electrical Emergency Triage](https://epri-peac.com/emergency/) [Find Licensed Electricians](https://epri-peac.com/pros/)