---
title: "Siemens / Murray QP / QT / MP Load Centers Breaker"
url: https://epri-peac.com/breakers/siemens-qp-murray/
description: "QP / QT / MP Load Centers, 1.00 in: UL-listed breakers, DIVQ swap eligibility, and 120% solar rules. Verified US government and CEC engineering data."
---

UL Listed / UL Classified DIVQ

# Siemens / Murray QP / QT / MP Load Centers — Breaker Compatibility

Standard: **UL 489 / UL 67 · NEC 110.3(B)** Verified: **2026-11-26**

Siemens / Murray QP / QT / MP Load Centers uses a 1.00 in busbar format; status: Active / UL Listed. Native breakers: Siemens QP, QT (tandem), QAF2, QFGA2, QDF2 (Murray MP phased into Siemens QP). Classified replacement rule: Eaton Type CL (UL Classified DIVQ for listed Siemens/Murray panels). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Busbar Format** : 1.00 in

- **Safety Tier** : Active / UL Listed

- **Native Breakers** : Siemens QP, QT (tandem), QAF2

- **Classified Swap** : Eaton Type CL (DIVQ)

Macro detail of copper panelboard busbar stabs and circuit breaker clip engagement mechanics

## What Is the Siemens / Murray QP / QT / MP Load Centers Inspection and Safety Profile?

Review UL 489 listing boundaries, busbar stab geometry, acceptable replacement hardware, and common field failure points documented for Siemens / Murray QP / QT / MP Load Centers.

Siemens QP and legacy Murray MP load centers share a 1.00-inch stab interface; Siemens formally discontinued the Murray brand and consolidated replacements under the QP/QT breaker line. Dual-pole quad QT breakers allow installers to consolidate two 120 V lighting circuits and one 240 V branch circuit without expanding cabinet size.

When evaluating Murray or Siemens panels for rooftop solar or battery storage, confirm whether the main busbar is rated 200 A or 225 A—225 A meter-main combos readily absorb a 60 A or 70 A backfeed breaker under the 120% rule.

## What Are the QP / QT / MP Load Centers Busbar and 120% Solar Backfeed Limits?

Technical panelboard limits below establish compatible main lug sizes, maximum ambient continuous breaker loading, and NEC 705.12(B)(3)(2) solar allowance.

Verified OEM bus stab geometry, DIVQ swap eligibility, and NEC 705.12 backfeed limits for Siemens / Murray QP / QT / MP Load Centers.

| Engineering Parameter | Specification | Field / Code Impact |
|---|---|---|
| **Bus Stab Pitch** | 1.00 in residential plug-on | Murray MP interiors transitioned directly into Siemens QP |
| **Native Branch Families** | QP, QT (tandem/quad), QAF2, QFGA2, QDF2 | Supports quad-plex space-saving 2-pole combinations |
| **UL Classified DIVQ Fit** | Eaton Type CL (listed Siemens/Murray panels) | Requires exact catalog match in DIVQ directory |
| **Murray Compatibility** | Siemens QP replaces Murray MP-T / MP-GT | Official Siemens/Murray UL substitution bulletin |
| **200A / 200A Max Solar Backfeed** | 40 A (7.68 kW AC @ 240 V) | 225 A Siemens busbar with 200 A main allows 70 A PV backfeed |
| **Main Breaker Derate Kit** | MBK150A / MBK175A (panel-specific) | Unlocks 65 A (175A derate) or 90 A (150A derate) PV backfeed |
| **EVSE 50A / 60A Branch Fit** | Q250 / Q260 (2-pole, 75 C lugs) | 60 A breaker needs 6 AWG Cu THHN (65 A @ 75 C); 6/2 NM-B fails at 55 A |

## How Does NEC 705.12 Calculate the 120% Solar Backfeed Allowance?

Follow the single-line busbar summation diagram below to verify main breaker plus PV backfeed capacity on a 200 A load center.

NEC 705.12(B)(3)(2) pins solar backfeed to the opposite end of a 200A busbar, capping a 200A/200A panel at 40A unless derated, tapped, or PCS-controlled.

## Which Panel Series Compare Most Closely to QP / QT / MP Load Centers?

Inspect peer load-center architectures across major UL-listed North American manufacturers before choosing replacement breakers or upgrading service panels.

Cross-check QP / QT / MP Load Centers against adjacent panel families.

| Panel Series | Bus Format | Tier | Classified Swap |
|---|---|---|---|
| [**Square D Homeline (HOM) Load Centers**](https://epri-peac.com/breakers/square-d-homeline/) | 1.00 in | Active / UL Listed | Eaton Type CL (UL Classified DIVQ for listed Homeline catalog numbers) |
| [**Eaton / Cutler-Hammer Type BR (Legacy Bryant / Westinghouse / Challenger)**](https://epri-peac.com/breakers/eaton-type-br/) | 1.00 in | Active / UL Listed | Eaton BR is UL Listed replacement for Bryant, Westinghouse BR, and Challenger Type C/A |
| [**GE / ABB PowerMark Gold / Pro (THQL / THQP)**](https://epri-peac.com/breakers/ge-powermark/) | 1.00 in full / 0.50 in thin THQP | Active / UL Listed | Eaton Type CL (UL Classified DIVQ for listed 1-inch GE panels) |

## Which CPSC Safety Recalls Match This Panel or Breaker Family? (3)

Matched U.S. Consumer Product Safety Commission hazard filings below help installers check date codes before servicing existing panels.

- [**Recall #24346 (2024-08-22)** — Siemens Industry Recalls SolarReady™ Meter Combos Due to Fire Hazard](https://epri-peac.com/recalls/24346-siemens-industry-recalls-solarready-meter-combos-due-t/)
- [**Recall #10354 (2010-09-23)** — Siemens Recalls Circuit Breakers Due to Fire Hazard](https://epri-peac.com/recalls/10354-siemens-recalls-circuit-breakers-due-to-fire-hazard/)
- [**Recall #88091 (1998-11-01)** — I-T-E Circuit Breaker Box Inspection Program Announced By Siemens](https://epri-peac.com/recalls/88091-i-t-e-circuit-breaker-box-inspection-program-announced/)

What to Check & Best-Fit Scenarios

## What Are the Limitations of Reference Data and Who Should Not Rely on It Alone?

Published government datasets and CEC lab ratings establish baseline electrical and solar bounds, subject to field verification at your specific property.

- Tariffs change mid-year: verify your electric utility's current net-billing export tariff and transformer capacity before signing contracts.
- NEC edition lags: state and city building departments enforce varying NEC editions (2017, 2020, 2023, or 2026) with local amendments.
- Not a substitute for on-site inspection: busbar pitting, ungrounded circuits, or loose neutral lugs require in-person testing by a licensed electrician.

### Grid-Outage Resilience Priority

Focus on high-SAIDI utilities (>180 min/yr) and verify 120% busbar capacity for a 60 A hybrid battery or 200 A transfer switch.

### Post-25D Cash Solar Payback Focus

With 0% federal 25D in 2026, prioritize higher-tariff markets above 18 c/kWh and avoid 20%-35% loan dealer fees.

### EV Charging & Circuit Safety

Hardwire 48 A chargers on 6 AWG Cu THHN (75 C) rather than 6/2 NM-B, or step down to 32 A (40 A breaker) on tight 100 A panels.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers below come directly from official California Energy Commission equipment lists, U.S. Energy Information Administration utility reports, National Electrical Code rules, IRS 2026 guidance, and state licensing boards.

### Can third-party classified breakers be used in Siemens / Murray QP / QT / MP Load Centers?

Eaton Type CL (UL Classified DIVQ for listed Siemens/Murray panels). Confirm exact catalog cross-reference table inside load center door. Check local building department permit requirements for Siemens Qp Murray before finalizing component orders.

### Can a 200 A Siemens / Murray QP / QT / MP Load Centers panel handle a 60 A EV charger and solar backfeed?

Obsolete FPE/Zinsco panels must be replaced prior to EVSE or solar additions. Active UL-listed 200 A/200 A panels allow 40 A of load-side solar backfeed under NEC 705.12(B)(3)(2), or 65 A with a 175 A main breaker derate.

### What breakers are UL Listed natively inside Siemens / Murray QP / QT / MP Load Centers load centers?

Only Siemens QP, QT (tandem), QAF2, QFGA2, QDF2 (Murray MP phased into Siemens QP) breakers carry direct UL 489 OEM factory listing inside Siemens / Murray QP / QT / MP Load Centers panels with 1.00 in busbar stabs without voiding panelboard warranty or NEC 110.3(B) inspection.

### Are UL Classified replacement breakers permitted in Siemens / Murray QP / QT / MP Load Centers panels?

For Siemens / Murray QP / QT / MP Load Centers enclosures using 1.00 in geometry, classified replacement guidance is Eaton Type CL (UL Classified DIVQ for listed Siemens/Murray panels); verify the exact UL Category DIVQ compatibility chart printed inside the panel door.

### Does Siemens / Murray QP / QT / MP Load Centers safety status affect home insurance or solar interconnection?

Siemens / Murray QP / QT / MP Load Centers holds tier 'Active / UL Listed'. Review insurer acceptance, physical busbar pitting, and NEC 705.12 120% backfeed clearance before adding heavy solar or EVSE loads.

### How do electricians inspect Siemens / Murray QP / QT / MP Load Centers busbar stabs safely?

After de-energizing where possible, a licensed electrician checks Siemens / Murray QP / QT / MP Load Centers stabs for thermal discoloration, loose spring-clip tension, double-tapped neutral bars, and calibrated NEC 110.14(D) lug torque.

### When should a Siemens / Murray QP / QT / MP Load Centers panel be replaced instead of repaired?

Obsolete fire-hazard enclosures, heat-damaged aluminum/copper bus stabs, rusted weatherproof cans, or maxed-out Siemens / Murray QP / QT / MP Load Centers main lugs warrant a full 200 A service panel replacement under permit.

### What makes an electrical contractor directory entry trustworthy versus a lead aggregator?

Government-sourced directories pull active license numbers directly from state regulatory agencies (TX TDLR, WA L&I, CO DORA, OR BCD, DE DPR) without paid rankings or synthetic reviews.

## Related Pages

Explore related homeowner calculators, state electricity rate guides, licensed electrician lists, safety recall alerts, and solar equipment datasheets across this directory.

[Full Circuit Breaker Cross-Reference Matrix](https://epri-peac.com/breakers/) [200 Amp Service Upgrade Wire Size & NEC 310.12](https://epri-peac.com/wire-size/200-amp/) [Emergency Electrical Triage: Hot Panels & Buzzing](https://epri-peac.com/emergency/hot-electrical-panel-buzzing-breaker/) [Verify State-Licensed Electrical Contractors](https://epri-peac.com/pros/)

## Sources

1. [UL Product iQ DIVQ Classified & Listed Circuit Breaker Compatibility Reference](https://productiq.ulprospector.com/) — UL Solutions / Panel OEM Datasheets (Square D, Eaton, Siemens, GE), 2026 OEM Cross-Reference (retrieved 2026-11-23)
2. [CPSC Publication 516: Repairing Aluminum Wiring](https://www.cpsc.gov/s3fs-public/516.pdf) — U.S. Consumer Product Safety Commission (CPSC), Pub. 516 (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Need a 200A Panel Upgrade?

Verify licensed electrical contractors before replacing FPE Stab-Lok, Zinsco, or 100A legacy panels.
[Verify Licensed Electricians](https://epri-peac.com/pros/) [Check 120% Solar Busbar Limit](https://epri-peac.com/tools/solar-busbar-120/)
