title: "GE / ABB PowerMark Gold / Pro (THQL / THQP) Breaker"
url: https://epri-peac.com/breakers/ge-powermark/
description: "PowerMark Gold / Pro (THQL / THQP), 1.00 in full / 0.50 in thin THQP: UL-listed breakers, DIVQ swap eligibility, and 120% solar rules."
---

UL Listed / UL Classified DIVQ

# GE / ABB PowerMark Gold / Pro (THQL / THQP) — Breaker Compatibility

Standard: **UL 489 / UL 67 · NEC 110.3(B)** Verified: **2026-11-26**

GE / ABB PowerMark Gold / Pro (THQL / THQP) uses a 1.00 in full / 0.50 in thin THQP busbar format; status: Active / UL Listed. Native breakers: GE / ABB THQL (1-in), THQP (1/2-in slim), THQL-AF2, THQL-GF2. Classified replacement rule: Eaton Type CL (UL Classified DIVQ for listed 1-inch GE panels). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **Busbar Format** : 1.00 in full / 0.50 in thin THQP

- **Safety Tier** : Active / UL Listed

- **Native Breakers** : GE / ABB THQL (1-in), THQP

- **Classified Swap** : Eaton Type CL (1-in DIVQ)

Macro detail of copper panelboard busbar stabs and circuit breaker clip engagement mechanics

## What Is the GE / ABB PowerMark Gold / Pro (THQL / THQP) Inspection and Safety Profile?

Review UL 489 listing boundaries, busbar stab geometry, acceptable replacement hardware, and common field failure points documented for GE / ABB PowerMark Gold / Pro (THQL / THQP).

GE PowerMark Gold and PowerMark Pro panels (now maintained under ABB) pair standard 1.00-inch THQL breakers with half-width 0.50-inch THQP slim breakers. Rather than molding two switches into a 1-inch twin housing, GE engineered cross-notched stabs on designated circuits so two independent THQP breakers occupy a single 1-inch space.

For continuous 40 A-60 A EV chargers and solar inverter feeders, installers favor full-width 1-inch THQL two-pole breakers over half-width THQP frames to maximize bus stab contact surface and thermal dissipation.

## What Are the PowerMark Gold / Pro (THQL / THQP) Busbar and 120% Solar Backfeed Limits?

Technical panelboard limits below establish compatible main lug sizes, maximum ambient continuous breaker loading, and NEC 705.12(B)(3)(2) solar allowance.

Verified OEM bus stab geometry, DIVQ swap eligibility, and NEC 705.12 backfeed limits for GE / ABB PowerMark Gold / Pro (THQL / THQP).

| Engineering Parameter | Specification | Field / Code Impact |
|---|---|---|
| **Bus Stab Pitch** | 1.00 in THQL / 0.50 in slim THQP | Half-inch THQP fits only cross-notched bus stab positions |
| **Native Branch Families** | THQL (1-in), THQP (1/2-in), THQL-AF2, THQL-GF2 | ABB acquired GE Industrial Solutions residential line |
| **UL Classified DIVQ Fit** | Eaton Type CL (listed 1-inch GE panels only) | Does NOT cover 0.50-in THQP thin slots |
| **Tandem Note** | Uses independent 0.50-in THQP modules instead of twins | 240 V 2-pole THQP spans two adjacent half-inch stabs |
| **200A / 200A Max Solar Backfeed** | 40 A (7.68 kW AC @ 240 V) | Use full-size 1-inch THQL2160 for 60 A EVSE/ESS circuits |
| **Inspection Watchpoint** | Verify horizontal stab notch presence | Forcing THQP onto un-notched stabs damages busbar clips |

## How Does NEC 705.12 Calculate the 120% Solar Backfeed Allowance?

Follow the single-line busbar summation diagram below to verify main breaker plus PV backfeed capacity on a 200 A load center.

NEC 705.12(B)(3)(2) pins solar backfeed to the opposite end of a 200A busbar, capping a 200A/200A panel at 40A unless derated, tapped, or PCS-controlled.

## Which Panel Series Compare Most Closely to PowerMark Gold / Pro (THQL / THQP)?

Inspect peer load-center architectures across major UL-listed North American manufacturers before choosing replacement breakers or upgrading service panels.

Cross-check PowerMark Gold / Pro (THQL / THQP) against adjacent panel families.

| Panel Series | Bus Format | Tier | Classified Swap |
|---|---|---|---|
| [**Eaton / Cutler-Hammer Type BR (Legacy Bryant / Westinghouse / Challenger)**](https://epri-peac.com/breakers/eaton-type-br/) | 1.00 in | Active / UL Listed | Eaton BR is UL Listed replacement for Bryant, Westinghouse BR, and Challenger Type C/A |
| [**Siemens / Murray QP / QT / MP Load Centers**](https://epri-peac.com/breakers/siemens-qp-murray/) | 1.00 in | Active / UL Listed | Eaton Type CL (UL Classified DIVQ for listed Siemens/Murray panels) |
| [**Square D Homeline (HOM) Load Centers**](https://epri-peac.com/breakers/square-d-homeline/) | 1.00 in | Active / UL Listed | Eaton Type CL (UL Classified DIVQ for listed Homeline catalog numbers) |

## Which CPSC Safety Recalls Match This Panel or Breaker Family? (1)

Matched U.S. Consumer Product Safety Commission hazard filings below help installers check date codes before servicing existing panels.

- [**Recall #88018 (1988-03-21)** — Surge Suppressors Recalled by GE](https://epri-peac.com/recalls/88018-surge-suppressors-recalled-by-ge/)

What to Check & Best-Fit Scenarios

## What Are the Limitations of Reference Data and Who Should Not Rely on It Alone?

Published government datasets and CEC lab ratings establish baseline electrical and solar bounds, subject to field verification at your specific property.

- Tariffs change mid-year: verify your electric utility's current net-billing export tariff and transformer capacity before signing contracts.
- NEC edition lags: state and city building departments enforce varying NEC editions (2017, 2020, 2023, or 2026) with local amendments.
- Not a substitute for on-site inspection: busbar pitting, ungrounded circuits, or loose neutral lugs require in-person testing by a licensed electrician.

### Grid-Outage Resilience Priority

Focus on high-SAIDI utilities (>180 min/yr) and verify 120% busbar capacity for a 60 A hybrid battery or 200 A transfer switch.

### Post-25D Cash Solar Payback Focus

With 0% federal 25D in 2026, prioritize higher-tariff markets above 18 c/kWh and avoid 20%-35% loan dealer fees.

### EV Charging & Circuit Safety

Hardwire 48 A chargers on 6 AWG Cu THHN (75 C) rather than 6/2 NM-B, or step down to 32 A (40 A breaker) on tight 100 A panels.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers below come directly from official California Energy Commission equipment lists, U.S. Energy Information Administration utility reports, National Electrical Code rules, IRS 2026 guidance, and state licensing boards.

### Can third-party classified breakers be used in GE / ABB PowerMark Gold / Pro (THQL / THQP)?

Eaton Type CL (UL Classified DIVQ for listed 1-inch GE panels). Half-inch THQP breakers fit only panel bus positions with horizontal slot notches. Check local building department permit requirements for Ge Powermark before finalizing component orders.

### Can a 200 A GE / ABB PowerMark Gold / Pro (THQL / THQP) panel handle a 60 A EV charger and solar backfeed?

Obsolete FPE/Zinsco panels must be replaced prior to EVSE or solar additions. Active UL-listed 200 A/200 A panels allow 40 A of load-side solar backfeed under NEC 705.12(B)(3)(2), or 65 A with a 175 A main breaker derate.

### What breakers are UL Listed natively inside GE / ABB PowerMark Gold / Pro (THQL / THQP) load centers?

Only GE / ABB THQL (1-in), THQP (1/2-in slim), THQL-AF2, THQL-GF2 breakers carry direct UL 489 OEM factory listing inside GE / ABB PowerMark Gold / Pro (THQL / THQP) panels with 1.00 in full / 0.50 in thin THQP busbar stabs without voiding panelboard warranty or NEC 110.3(B) inspection.

### Are UL Classified replacement breakers permitted in GE / ABB PowerMark Gold / Pro (THQL / THQP) panels?

For GE / ABB PowerMark Gold / Pro (THQL / THQP) enclosures using 1.00 in full / 0.50 in thin THQP geometry, classified replacement guidance is Eaton Type CL (UL Classified DIVQ for listed 1-inch GE panels); verify the exact UL Category DIVQ compatibility chart printed inside the panel door.

### Does GE / ABB PowerMark Gold / Pro (THQL / THQP) safety status affect home insurance or solar interconnection?

GE / ABB PowerMark Gold / Pro (THQL / THQP) holds tier 'Active / UL Listed'. Review insurer acceptance, physical busbar pitting, and NEC 705.12 120% backfeed clearance before adding heavy solar or EVSE loads.

### How do electricians inspect GE / ABB PowerMark Gold / Pro (THQL / THQP) busbar stabs safely?

After de-energizing where possible, a licensed electrician checks GE / ABB PowerMark Gold / Pro (THQL / THQP) stabs for thermal discoloration, loose spring-clip tension, double-tapped neutral bars, and calibrated NEC 110.14(D) lug torque.

### When should a GE / ABB PowerMark Gold / Pro (THQL / THQP) panel be replaced instead of repaired?

Obsolete fire-hazard enclosures, heat-damaged aluminum/copper bus stabs, rusted weatherproof cans, or maxed-out GE / ABB PowerMark Gold / Pro (THQL / THQP) main lugs warrant a full 200 A service panel replacement under permit.

### Why do 240 V garage EV outlets trip GFCI breakers while hardwired units do not?

NEC 210.8 and 625.54 mandate Class A GFCI protection on garage 240 V receptacles, which can conflict with an EV charger's internal CCID ground check unless hardwired.

## Related Pages

Explore related homeowner calculators, state electricity rate guides, licensed electrician lists, safety recall alerts, and solar equipment datasheets across this directory.

[Full Circuit Breaker Cross-Reference Matrix](https://epri-peac.com/breakers/) [200 Amp Service Upgrade Wire Size & NEC 310.12](https://epri-peac.com/wire-size/200-amp/) [Emergency Electrical Triage: Hot Panels & Buzzing](https://epri-peac.com/emergency/hot-electrical-panel-buzzing-breaker/) [Verify State-Licensed Electrical Contractors](https://epri-peac.com/pros/)

## Sources

1. [UL Product iQ DIVQ Classified & Listed Circuit Breaker Compatibility Reference](https://productiq.ulprospector.com/) — UL Solutions / Panel OEM Datasheets (Square D, Eaton, Siemens, GE), 2026 OEM Cross-Reference (retrieved 2026-11-23)
2. [CPSC Publication 516: Repairing Aluminum Wiring](https://www.cpsc.gov/s3fs-public/516.pdf) — U.S. Consumer Product Safety Commission (CPSC), Pub. 516 (retrieved 2026-11-23)
3. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
4. [CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar)](https://www.saferproducts.gov/RestWebServices/Recall) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Need a 200A Panel Upgrade?

Verify licensed electrical contractors before replacing FPE Stab-Lok, Zinsco, or 100A legacy panels.
[Verify Licensed Electricians](https://epri-peac.com/pros/) [Check 120% Solar Busbar Limit](https://epri-peac.com/tools/solar-busbar-120/)